3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification

Joseph Stancanello, Alexander Muacevic, Fabio Sebastiano, Nicola Modugno, Pietro Cerveri, Giancarlo Ferrigno, Fulvio Uggeri, Pantaleo Romanelli

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial border of the STN often blends with the substantia nigra. 3 T magnetic resonance imaging (MRI) provides better resolution and can improve the identification of the STN borders. In this work, we have directly identified the STN using 3 T MR imaging to validate the accuracy of a computer-aided atlas-based procedure for automatic STN identification. Coordinates of the STN were obtained from the Talairach and Tournoux atlas and transformed into the coordinates of the Montreal Neurological Institute (MNI) standard brain volume, creating a mask representation of the STN. 3 T volumetric T1 and T2 weighted (T1w and T2w, respectively) acquisitions were obtained for ten patients. The MNI standard brain volume was registered onto each patient MRI, using a new approach based on global affine, region-of-interest affine, and local nonrigid registrations. The estimated deformation field was then applied to the STN atlas-based mask, providing its location on the patient MRI. The entire procedure required on average about 20 min. Because STN is easily identifiable on 3 T T2w-MRIs, it was manually delineated; the coordinates of the center of mass of the manually and automatically identified structures were compared. Additionally, volumetric overlapping indices were calculated and the spatial relationship between the midcommissural point and the STN center of mass was investigated. All indices indicated, on average, good agreement between manually and automatically identified structures; displacement of the centers of mass of the manually and automatically identified structures was less than or equal to 2.35 mm, and more than 80% of the manually identified volume was covered by the automatic localization, on average. Bland-Altman analysis indicated that the automatic STN identification was within the limits of agreement with the manual localization on 3 T MRIs. Automatic atlas-based STN localization provides an accurate and user-friendly tool and can enhance target identification when 1.5 T scanners with limited capability to identify the STN boundaries are used.

Original languageEnglish
Pages (from-to)3069-3077
Number of pages9
JournalMedical Physics
Volume35
Issue number7
DOIs
Publication statusPublished - 2008

Fingerprint

Subthalamic Nucleus
Atlases
Magnetic Resonance Imaging
Masks
Deep Brain Stimulation
Brain
Substantia Nigra

Keywords

  • 3 T MRI
  • Atlas-based identification
  • Functional neurosurgery
  • Image guidance
  • Nonrigid registration
  • Subthalamic nucleus

ASJC Scopus subject areas

  • Biophysics

Cite this

Stancanello, J., Muacevic, A., Sebastiano, F., Modugno, N., Cerveri, P., Ferrigno, G., ... Romanelli, P. (2008). 3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification. Medical Physics, 35(7), 3069-3077. https://doi.org/10.1118/1.2936229

3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification. / Stancanello, Joseph; Muacevic, Alexander; Sebastiano, Fabio; Modugno, Nicola; Cerveri, Pietro; Ferrigno, Giancarlo; Uggeri, Fulvio; Romanelli, Pantaleo.

In: Medical Physics, Vol. 35, No. 7, 2008, p. 3069-3077.

Research output: Contribution to journalArticle

Stancanello, J, Muacevic, A, Sebastiano, F, Modugno, N, Cerveri, P, Ferrigno, G, Uggeri, F & Romanelli, P 2008, '3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification', Medical Physics, vol. 35, no. 7, pp. 3069-3077. https://doi.org/10.1118/1.2936229
Stancanello J, Muacevic A, Sebastiano F, Modugno N, Cerveri P, Ferrigno G et al. 3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification. Medical Physics. 2008;35(7):3069-3077. https://doi.org/10.1118/1.2936229
Stancanello, Joseph ; Muacevic, Alexander ; Sebastiano, Fabio ; Modugno, Nicola ; Cerveri, Pietro ; Ferrigno, Giancarlo ; Uggeri, Fulvio ; Romanelli, Pantaleo. / 3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification. In: Medical Physics. 2008 ; Vol. 35, No. 7. pp. 3069-3077.
@article{548aa03c9e5c462ebd7cecd24ce2cf5f,
title = "3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification",
abstract = "Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial border of the STN often blends with the substantia nigra. 3 T magnetic resonance imaging (MRI) provides better resolution and can improve the identification of the STN borders. In this work, we have directly identified the STN using 3 T MR imaging to validate the accuracy of a computer-aided atlas-based procedure for automatic STN identification. Coordinates of the STN were obtained from the Talairach and Tournoux atlas and transformed into the coordinates of the Montreal Neurological Institute (MNI) standard brain volume, creating a mask representation of the STN. 3 T volumetric T1 and T2 weighted (T1w and T2w, respectively) acquisitions were obtained for ten patients. The MNI standard brain volume was registered onto each patient MRI, using a new approach based on global affine, region-of-interest affine, and local nonrigid registrations. The estimated deformation field was then applied to the STN atlas-based mask, providing its location on the patient MRI. The entire procedure required on average about 20 min. Because STN is easily identifiable on 3 T T2w-MRIs, it was manually delineated; the coordinates of the center of mass of the manually and automatically identified structures were compared. Additionally, volumetric overlapping indices were calculated and the spatial relationship between the midcommissural point and the STN center of mass was investigated. All indices indicated, on average, good agreement between manually and automatically identified structures; displacement of the centers of mass of the manually and automatically identified structures was less than or equal to 2.35 mm, and more than 80{\%} of the manually identified volume was covered by the automatic localization, on average. Bland-Altman analysis indicated that the automatic STN identification was within the limits of agreement with the manual localization on 3 T MRIs. Automatic atlas-based STN localization provides an accurate and user-friendly tool and can enhance target identification when 1.5 T scanners with limited capability to identify the STN boundaries are used.",
keywords = "3 T MRI, Atlas-based identification, Functional neurosurgery, Image guidance, Nonrigid registration, Subthalamic nucleus",
author = "Joseph Stancanello and Alexander Muacevic and Fabio Sebastiano and Nicola Modugno and Pietro Cerveri and Giancarlo Ferrigno and Fulvio Uggeri and Pantaleo Romanelli",
year = "2008",
doi = "10.1118/1.2936229",
language = "English",
volume = "35",
pages = "3069--3077",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "John Wiley and Sons Ltd",
number = "7",

}

TY - JOUR

T1 - 3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification

AU - Stancanello, Joseph

AU - Muacevic, Alexander

AU - Sebastiano, Fabio

AU - Modugno, Nicola

AU - Cerveri, Pietro

AU - Ferrigno, Giancarlo

AU - Uggeri, Fulvio

AU - Romanelli, Pantaleo

PY - 2008

Y1 - 2008

N2 - Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial border of the STN often blends with the substantia nigra. 3 T magnetic resonance imaging (MRI) provides better resolution and can improve the identification of the STN borders. In this work, we have directly identified the STN using 3 T MR imaging to validate the accuracy of a computer-aided atlas-based procedure for automatic STN identification. Coordinates of the STN were obtained from the Talairach and Tournoux atlas and transformed into the coordinates of the Montreal Neurological Institute (MNI) standard brain volume, creating a mask representation of the STN. 3 T volumetric T1 and T2 weighted (T1w and T2w, respectively) acquisitions were obtained for ten patients. The MNI standard brain volume was registered onto each patient MRI, using a new approach based on global affine, region-of-interest affine, and local nonrigid registrations. The estimated deformation field was then applied to the STN atlas-based mask, providing its location on the patient MRI. The entire procedure required on average about 20 min. Because STN is easily identifiable on 3 T T2w-MRIs, it was manually delineated; the coordinates of the center of mass of the manually and automatically identified structures were compared. Additionally, volumetric overlapping indices were calculated and the spatial relationship between the midcommissural point and the STN center of mass was investigated. All indices indicated, on average, good agreement between manually and automatically identified structures; displacement of the centers of mass of the manually and automatically identified structures was less than or equal to 2.35 mm, and more than 80% of the manually identified volume was covered by the automatic localization, on average. Bland-Altman analysis indicated that the automatic STN identification was within the limits of agreement with the manual localization on 3 T MRIs. Automatic atlas-based STN localization provides an accurate and user-friendly tool and can enhance target identification when 1.5 T scanners with limited capability to identify the STN boundaries are used.

AB - Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial border of the STN often blends with the substantia nigra. 3 T magnetic resonance imaging (MRI) provides better resolution and can improve the identification of the STN borders. In this work, we have directly identified the STN using 3 T MR imaging to validate the accuracy of a computer-aided atlas-based procedure for automatic STN identification. Coordinates of the STN were obtained from the Talairach and Tournoux atlas and transformed into the coordinates of the Montreal Neurological Institute (MNI) standard brain volume, creating a mask representation of the STN. 3 T volumetric T1 and T2 weighted (T1w and T2w, respectively) acquisitions were obtained for ten patients. The MNI standard brain volume was registered onto each patient MRI, using a new approach based on global affine, region-of-interest affine, and local nonrigid registrations. The estimated deformation field was then applied to the STN atlas-based mask, providing its location on the patient MRI. The entire procedure required on average about 20 min. Because STN is easily identifiable on 3 T T2w-MRIs, it was manually delineated; the coordinates of the center of mass of the manually and automatically identified structures were compared. Additionally, volumetric overlapping indices were calculated and the spatial relationship between the midcommissural point and the STN center of mass was investigated. All indices indicated, on average, good agreement between manually and automatically identified structures; displacement of the centers of mass of the manually and automatically identified structures was less than or equal to 2.35 mm, and more than 80% of the manually identified volume was covered by the automatic localization, on average. Bland-Altman analysis indicated that the automatic STN identification was within the limits of agreement with the manual localization on 3 T MRIs. Automatic atlas-based STN localization provides an accurate and user-friendly tool and can enhance target identification when 1.5 T scanners with limited capability to identify the STN boundaries are used.

KW - 3 T MRI

KW - Atlas-based identification

KW - Functional neurosurgery

KW - Image guidance

KW - Nonrigid registration

KW - Subthalamic nucleus

UR - http://www.scopus.com/inward/record.url?scp=46149126425&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=46149126425&partnerID=8YFLogxK

U2 - 10.1118/1.2936229

DO - 10.1118/1.2936229

M3 - Article

C2 - 18697530

AN - SCOPUS:46149126425

VL - 35

SP - 3069

EP - 3077

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 7

ER -