4D ML reconstruction as a tool for volumetric PET-based treatment verification in ion beam radiotherapy

E. De Bernardi, R. Ricotti, M. Riboldi, G. Baroni, K. Parodi, C. Gianoli

Research output: Contribution to journalArticle

Abstract

Purpose: An innovative strategy to improve the sensitivity of positron emission tomography (PET)- based treatment verification in ion beam radiotherapy is proposed. Methods: Low counting statistics PET images acquired during or shortly after the treatment (Measured PET) and a Monte Carlo estimate of the same PET images derived from the treatment plan (Expected PET) are considered as two frames of a 4D dataset. A 4D maximum likelihood reconstruction strategy was adapted to iteratively estimate the annihilation events distribution in a reference frame and the deformation motion fields that map it in the Expected PET and Measured PET frames. The outputs generated by the proposed strategy are as follows: (1) an estimate of the Measured PET with an image quality comparable to the Expected PET and (2) an estimate of the motion field mapping Expected PET to Measured PET. The details of the algorithm are presented and the strategy is preliminarily tested on analytically simulated datasets. Results: The algorithm demonstrates (1) robustness against noise, even in the worst conditions where 1.5-104 true coincidences and a random fraction of 73% are simulated; (2) a proper sensitivity to different kind and grade of mismatches ranging between 1 and 10 mm; (3) robustness against bias due to incorrect washout modeling in the Monte Carlo simulation up to 1/3 of the original signal amplitude; and (4) an ability to describe the mismatch even in presence of complex annihilation distributions such as those induced by two perpendicular superimposed ion fields. Conclusions: The promising results obtained in this work suggest the applicability of the method as a quantification tool for PET-based treatment verification in ion beam radiotherapy. An extensive assessment of the proposed strategy on real treatment verification data is planned.

Original languageEnglish
Pages (from-to)710-726
Number of pages17
JournalMedical Physics
Volume43
Issue number2
DOIs
Publication statusPublished - Feb 1 2016

Fingerprint

Positron-Emission Tomography
Radiotherapy
Ions
Therapeutics
Noise

Keywords

  • 4D ML reconstruction
  • ion beam therapy
  • PET-based treatment verification
  • positron emission tomography (PET)

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

De Bernardi, E., Ricotti, R., Riboldi, M., Baroni, G., Parodi, K., & Gianoli, C. (2016). 4D ML reconstruction as a tool for volumetric PET-based treatment verification in ion beam radiotherapy. Medical Physics, 43(2), 710-726. https://doi.org/10.1118/1.4939227

4D ML reconstruction as a tool for volumetric PET-based treatment verification in ion beam radiotherapy. / De Bernardi, E.; Ricotti, R.; Riboldi, M.; Baroni, G.; Parodi, K.; Gianoli, C.

In: Medical Physics, Vol. 43, No. 2, 01.02.2016, p. 710-726.

Research output: Contribution to journalArticle

De Bernardi, E, Ricotti, R, Riboldi, M, Baroni, G, Parodi, K & Gianoli, C 2016, '4D ML reconstruction as a tool for volumetric PET-based treatment verification in ion beam radiotherapy', Medical Physics, vol. 43, no. 2, pp. 710-726. https://doi.org/10.1118/1.4939227
De Bernardi, E. ; Ricotti, R. ; Riboldi, M. ; Baroni, G. ; Parodi, K. ; Gianoli, C. / 4D ML reconstruction as a tool for volumetric PET-based treatment verification in ion beam radiotherapy. In: Medical Physics. 2016 ; Vol. 43, No. 2. pp. 710-726.
@article{5b36bd961ecc439aafc6f7d32103c354,
title = "4D ML reconstruction as a tool for volumetric PET-based treatment verification in ion beam radiotherapy",
abstract = "Purpose: An innovative strategy to improve the sensitivity of positron emission tomography (PET)- based treatment verification in ion beam radiotherapy is proposed. Methods: Low counting statistics PET images acquired during or shortly after the treatment (Measured PET) and a Monte Carlo estimate of the same PET images derived from the treatment plan (Expected PET) are considered as two frames of a 4D dataset. A 4D maximum likelihood reconstruction strategy was adapted to iteratively estimate the annihilation events distribution in a reference frame and the deformation motion fields that map it in the Expected PET and Measured PET frames. The outputs generated by the proposed strategy are as follows: (1) an estimate of the Measured PET with an image quality comparable to the Expected PET and (2) an estimate of the motion field mapping Expected PET to Measured PET. The details of the algorithm are presented and the strategy is preliminarily tested on analytically simulated datasets. Results: The algorithm demonstrates (1) robustness against noise, even in the worst conditions where 1.5-104 true coincidences and a random fraction of 73{\%} are simulated; (2) a proper sensitivity to different kind and grade of mismatches ranging between 1 and 10 mm; (3) robustness against bias due to incorrect washout modeling in the Monte Carlo simulation up to 1/3 of the original signal amplitude; and (4) an ability to describe the mismatch even in presence of complex annihilation distributions such as those induced by two perpendicular superimposed ion fields. Conclusions: The promising results obtained in this work suggest the applicability of the method as a quantification tool for PET-based treatment verification in ion beam radiotherapy. An extensive assessment of the proposed strategy on real treatment verification data is planned.",
keywords = "4D ML reconstruction, ion beam therapy, PET-based treatment verification, positron emission tomography (PET)",
author = "{De Bernardi}, E. and R. Ricotti and M. Riboldi and G. Baroni and K. Parodi and C. Gianoli",
year = "2016",
month = "2",
day = "1",
doi = "10.1118/1.4939227",
language = "English",
volume = "43",
pages = "710--726",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "John Wiley and Sons Ltd",
number = "2",

}

TY - JOUR

T1 - 4D ML reconstruction as a tool for volumetric PET-based treatment verification in ion beam radiotherapy

AU - De Bernardi, E.

AU - Ricotti, R.

AU - Riboldi, M.

AU - Baroni, G.

AU - Parodi, K.

AU - Gianoli, C.

PY - 2016/2/1

Y1 - 2016/2/1

N2 - Purpose: An innovative strategy to improve the sensitivity of positron emission tomography (PET)- based treatment verification in ion beam radiotherapy is proposed. Methods: Low counting statistics PET images acquired during or shortly after the treatment (Measured PET) and a Monte Carlo estimate of the same PET images derived from the treatment plan (Expected PET) are considered as two frames of a 4D dataset. A 4D maximum likelihood reconstruction strategy was adapted to iteratively estimate the annihilation events distribution in a reference frame and the deformation motion fields that map it in the Expected PET and Measured PET frames. The outputs generated by the proposed strategy are as follows: (1) an estimate of the Measured PET with an image quality comparable to the Expected PET and (2) an estimate of the motion field mapping Expected PET to Measured PET. The details of the algorithm are presented and the strategy is preliminarily tested on analytically simulated datasets. Results: The algorithm demonstrates (1) robustness against noise, even in the worst conditions where 1.5-104 true coincidences and a random fraction of 73% are simulated; (2) a proper sensitivity to different kind and grade of mismatches ranging between 1 and 10 mm; (3) robustness against bias due to incorrect washout modeling in the Monte Carlo simulation up to 1/3 of the original signal amplitude; and (4) an ability to describe the mismatch even in presence of complex annihilation distributions such as those induced by two perpendicular superimposed ion fields. Conclusions: The promising results obtained in this work suggest the applicability of the method as a quantification tool for PET-based treatment verification in ion beam radiotherapy. An extensive assessment of the proposed strategy on real treatment verification data is planned.

AB - Purpose: An innovative strategy to improve the sensitivity of positron emission tomography (PET)- based treatment verification in ion beam radiotherapy is proposed. Methods: Low counting statistics PET images acquired during or shortly after the treatment (Measured PET) and a Monte Carlo estimate of the same PET images derived from the treatment plan (Expected PET) are considered as two frames of a 4D dataset. A 4D maximum likelihood reconstruction strategy was adapted to iteratively estimate the annihilation events distribution in a reference frame and the deformation motion fields that map it in the Expected PET and Measured PET frames. The outputs generated by the proposed strategy are as follows: (1) an estimate of the Measured PET with an image quality comparable to the Expected PET and (2) an estimate of the motion field mapping Expected PET to Measured PET. The details of the algorithm are presented and the strategy is preliminarily tested on analytically simulated datasets. Results: The algorithm demonstrates (1) robustness against noise, even in the worst conditions where 1.5-104 true coincidences and a random fraction of 73% are simulated; (2) a proper sensitivity to different kind and grade of mismatches ranging between 1 and 10 mm; (3) robustness against bias due to incorrect washout modeling in the Monte Carlo simulation up to 1/3 of the original signal amplitude; and (4) an ability to describe the mismatch even in presence of complex annihilation distributions such as those induced by two perpendicular superimposed ion fields. Conclusions: The promising results obtained in this work suggest the applicability of the method as a quantification tool for PET-based treatment verification in ion beam radiotherapy. An extensive assessment of the proposed strategy on real treatment verification data is planned.

KW - 4D ML reconstruction

KW - ion beam therapy

KW - PET-based treatment verification

KW - positron emission tomography (PET)

UR - http://www.scopus.com/inward/record.url?scp=84954348624&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84954348624&partnerID=8YFLogxK

U2 - 10.1118/1.4939227

DO - 10.1118/1.4939227

M3 - Article

AN - SCOPUS:84954348624

VL - 43

SP - 710

EP - 726

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 2

ER -