A 3-DOF parallel robot with spherical motion for the rehabilitation and evaluation of balance performance

Fabrizio Patanè, Paolo Cappa

Research output: Contribution to journalArticle

22 Citations (Scopus)

Abstract

In this paper a novel electrically actuated parallel robot with three degrees-of-freedom (3 DOF) for dynamic postural studies is presented. The design has been described, the solution to the inverse kinematics has been found, and a numerical solution for the direct kinematics has been proposed. The workspace of the implemented robot is characterized by an angular range of motion of about ±10° for roll and pitch when yaw is in the range ±15°. The robot was constructed and the orientation accuracy was tested by means of an optoelectronic system and by imposing a sinusoidal input, with a frequency of 1 Hz and amplitude of 10°, along the three axes, in sequence. The collected data indicated a phase delay of 1° and an amplitude error of 0.5%1.5%; similar values were observed for cross-axis sensitivity errors. We also conducted a clinical application on a group of normal subjects, who were standing in equilibrium on the robot base with eyes open (EO) and eyes closed (EC), which was rotated with a tri-axial sinusoidal trajectory with a frequency of 0.5 Hz and amplitude 5 ° for roll and pitch and 10° for the yaw. The postural configuration of the subjects was recorded with an optoelectronic system. However, due to the mainly technical nature of this paper, only initial validation outcomes are reported here. The clinical application showed that only the tilt and displacement on the sagittal pane of head, trunk, and pelvis in the trials conducted with eyes closed were affected by drift and that the reduction of the yaw rotation and of the mediolateral translation was not a controlled parameter, as happened, instead, for the other anatomical directions.

Original languageEnglish
Article number5608506
Pages (from-to)157-166
Number of pages10
JournalIEEE Transactions on Neural Systems and Rehabilitation Engineering
Volume19
Issue number2
DOIs
Publication statusPublished - Apr 2011

Fingerprint

Yaws
Patient rehabilitation
Rehabilitation
Robots
Biomechanical Phenomena
Optoelectronic devices
Articular Range of Motion
Pelvis
Inverse kinematics
Degrees of freedom (mechanics)
Head
Kinematics
Trajectories

Keywords

  • Balance
  • dynamic posturography
  • moving platform
  • parallel robots
  • rehabilitation

ASJC Scopus subject areas

  • Neuroscience(all)
  • Computer Science Applications
  • Biomedical Engineering
  • Medicine(all)

Cite this

A 3-DOF parallel robot with spherical motion for the rehabilitation and evaluation of balance performance. / Patanè, Fabrizio; Cappa, Paolo.

In: IEEE Transactions on Neural Systems and Rehabilitation Engineering, Vol. 19, No. 2, 5608506, 04.2011, p. 157-166.

Research output: Contribution to journalArticle

@article{93d0f11bcd614ec4a13ab14e94fd5413,
title = "A 3-DOF parallel robot with spherical motion for the rehabilitation and evaluation of balance performance",
abstract = "In this paper a novel electrically actuated parallel robot with three degrees-of-freedom (3 DOF) for dynamic postural studies is presented. The design has been described, the solution to the inverse kinematics has been found, and a numerical solution for the direct kinematics has been proposed. The workspace of the implemented robot is characterized by an angular range of motion of about ±10° for roll and pitch when yaw is in the range ±15°. The robot was constructed and the orientation accuracy was tested by means of an optoelectronic system and by imposing a sinusoidal input, with a frequency of 1 Hz and amplitude of 10°, along the three axes, in sequence. The collected data indicated a phase delay of 1° and an amplitude error of 0.5{\%}1.5{\%}; similar values were observed for cross-axis sensitivity errors. We also conducted a clinical application on a group of normal subjects, who were standing in equilibrium on the robot base with eyes open (EO) and eyes closed (EC), which was rotated with a tri-axial sinusoidal trajectory with a frequency of 0.5 Hz and amplitude 5 ° for roll and pitch and 10° for the yaw. The postural configuration of the subjects was recorded with an optoelectronic system. However, due to the mainly technical nature of this paper, only initial validation outcomes are reported here. The clinical application showed that only the tilt and displacement on the sagittal pane of head, trunk, and pelvis in the trials conducted with eyes closed were affected by drift and that the reduction of the yaw rotation and of the mediolateral translation was not a controlled parameter, as happened, instead, for the other anatomical directions.",
keywords = "Balance, dynamic posturography, moving platform, parallel robots, rehabilitation",
author = "Fabrizio Patan{\`e} and Paolo Cappa",
year = "2011",
month = "4",
doi = "10.1109/TNSRE.2010.2089535",
language = "English",
volume = "19",
pages = "157--166",
journal = "IEEE Transactions on Neural Systems and Rehabilitation Engineering",
issn = "1534-4320",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "2",

}

TY - JOUR

T1 - A 3-DOF parallel robot with spherical motion for the rehabilitation and evaluation of balance performance

AU - Patanè, Fabrizio

AU - Cappa, Paolo

PY - 2011/4

Y1 - 2011/4

N2 - In this paper a novel electrically actuated parallel robot with three degrees-of-freedom (3 DOF) for dynamic postural studies is presented. The design has been described, the solution to the inverse kinematics has been found, and a numerical solution for the direct kinematics has been proposed. The workspace of the implemented robot is characterized by an angular range of motion of about ±10° for roll and pitch when yaw is in the range ±15°. The robot was constructed and the orientation accuracy was tested by means of an optoelectronic system and by imposing a sinusoidal input, with a frequency of 1 Hz and amplitude of 10°, along the three axes, in sequence. The collected data indicated a phase delay of 1° and an amplitude error of 0.5%1.5%; similar values were observed for cross-axis sensitivity errors. We also conducted a clinical application on a group of normal subjects, who were standing in equilibrium on the robot base with eyes open (EO) and eyes closed (EC), which was rotated with a tri-axial sinusoidal trajectory with a frequency of 0.5 Hz and amplitude 5 ° for roll and pitch and 10° for the yaw. The postural configuration of the subjects was recorded with an optoelectronic system. However, due to the mainly technical nature of this paper, only initial validation outcomes are reported here. The clinical application showed that only the tilt and displacement on the sagittal pane of head, trunk, and pelvis in the trials conducted with eyes closed were affected by drift and that the reduction of the yaw rotation and of the mediolateral translation was not a controlled parameter, as happened, instead, for the other anatomical directions.

AB - In this paper a novel electrically actuated parallel robot with three degrees-of-freedom (3 DOF) for dynamic postural studies is presented. The design has been described, the solution to the inverse kinematics has been found, and a numerical solution for the direct kinematics has been proposed. The workspace of the implemented robot is characterized by an angular range of motion of about ±10° for roll and pitch when yaw is in the range ±15°. The robot was constructed and the orientation accuracy was tested by means of an optoelectronic system and by imposing a sinusoidal input, with a frequency of 1 Hz and amplitude of 10°, along the three axes, in sequence. The collected data indicated a phase delay of 1° and an amplitude error of 0.5%1.5%; similar values were observed for cross-axis sensitivity errors. We also conducted a clinical application on a group of normal subjects, who were standing in equilibrium on the robot base with eyes open (EO) and eyes closed (EC), which was rotated with a tri-axial sinusoidal trajectory with a frequency of 0.5 Hz and amplitude 5 ° for roll and pitch and 10° for the yaw. The postural configuration of the subjects was recorded with an optoelectronic system. However, due to the mainly technical nature of this paper, only initial validation outcomes are reported here. The clinical application showed that only the tilt and displacement on the sagittal pane of head, trunk, and pelvis in the trials conducted with eyes closed were affected by drift and that the reduction of the yaw rotation and of the mediolateral translation was not a controlled parameter, as happened, instead, for the other anatomical directions.

KW - Balance

KW - dynamic posturography

KW - moving platform

KW - parallel robots

KW - rehabilitation

UR - http://www.scopus.com/inward/record.url?scp=79954485342&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79954485342&partnerID=8YFLogxK

U2 - 10.1109/TNSRE.2010.2089535

DO - 10.1109/TNSRE.2010.2089535

M3 - Article

C2 - 20977987

AN - SCOPUS:79954485342

VL - 19

SP - 157

EP - 166

JO - IEEE Transactions on Neural Systems and Rehabilitation Engineering

JF - IEEE Transactions on Neural Systems and Rehabilitation Engineering

SN - 1534-4320

IS - 2

M1 - 5608506

ER -