A geometrical perspective on the 3TP method in DCE-MRI

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

The 3TP (three time points) method has been proposed for producing high-resolution pseudo-coloured maps related to the angiogenic activity in breast DCE-MRI. In the original formulation of the method, the three time-points have been chosen on an empirical basis: the algorithm for benign/malignant/uncertain classification of a voxel was to be as simple as possible and the corresponding regions of the parameters space (according to the Tofts' model) were to occupy approximately the same area. Since its inception, the method has been largely used in clinical environment, due to its simplicity and soundness. However, as only three time-points are used to evaluate the characteristics of the complex time-course of the contrast medium within capillaries, noise can result in voxel misclassification, as we show in this study. In this paper we analysed the performances of the method from a geometrical perspective, based on the concept of confidence region, and we proposed an 'optimal' choice of the three time-points, in order to reduce the misclassification to a minimum. Comparing the original 3TP method with our proposal on the basis of misclassification rate, our results show that the modified 3TP method can lead to better performance. Preliminary results on real data have been also reported. Moreover, our proposal has a sounding mathematical basis and is easily generalisable to the case of more than two parameters and to other modalities such as DCE-CT.

Original languageEnglish
Pages (from-to)32-39
Number of pages8
JournalBiomedical Signal Processing and Control
Volume16
DOIs
Publication statusPublished - 2015

Fingerprint

Contrast media
Magnetic resonance imaging
Contrast Media
Noise
Breast

Keywords

  • 3TP method
  • Confidence region
  • DCE-MRI
  • Nonlinear regression
  • Optimal design
  • Tofts model

ASJC Scopus subject areas

  • Health Informatics
  • Signal Processing

Cite this

A geometrical perspective on the 3TP method in DCE-MRI. / Sansone, Mario; Fusco, Roberta; Petrillo, Antonella.

In: Biomedical Signal Processing and Control, Vol. 16, 2015, p. 32-39.

Research output: Contribution to journalArticle

@article{5d4b1f357a3041b29a0bb62942a276ee,
title = "A geometrical perspective on the 3TP method in DCE-MRI",
abstract = "The 3TP (three time points) method has been proposed for producing high-resolution pseudo-coloured maps related to the angiogenic activity in breast DCE-MRI. In the original formulation of the method, the three time-points have been chosen on an empirical basis: the algorithm for benign/malignant/uncertain classification of a voxel was to be as simple as possible and the corresponding regions of the parameters space (according to the Tofts' model) were to occupy approximately the same area. Since its inception, the method has been largely used in clinical environment, due to its simplicity and soundness. However, as only three time-points are used to evaluate the characteristics of the complex time-course of the contrast medium within capillaries, noise can result in voxel misclassification, as we show in this study. In this paper we analysed the performances of the method from a geometrical perspective, based on the concept of confidence region, and we proposed an 'optimal' choice of the three time-points, in order to reduce the misclassification to a minimum. Comparing the original 3TP method with our proposal on the basis of misclassification rate, our results show that the modified 3TP method can lead to better performance. Preliminary results on real data have been also reported. Moreover, our proposal has a sounding mathematical basis and is easily generalisable to the case of more than two parameters and to other modalities such as DCE-CT.",
keywords = "3TP method, Confidence region, DCE-MRI, Nonlinear regression, Optimal design, Tofts model",
author = "Mario Sansone and Roberta Fusco and Antonella Petrillo",
year = "2015",
doi = "10.1016/j.bspc.2014.10.004",
language = "English",
volume = "16",
pages = "32--39",
journal = "Biomedical Signal Processing and Control",
issn = "1746-8094",
publisher = "Elsevier BV",

}

TY - JOUR

T1 - A geometrical perspective on the 3TP method in DCE-MRI

AU - Sansone, Mario

AU - Fusco, Roberta

AU - Petrillo, Antonella

PY - 2015

Y1 - 2015

N2 - The 3TP (three time points) method has been proposed for producing high-resolution pseudo-coloured maps related to the angiogenic activity in breast DCE-MRI. In the original formulation of the method, the three time-points have been chosen on an empirical basis: the algorithm for benign/malignant/uncertain classification of a voxel was to be as simple as possible and the corresponding regions of the parameters space (according to the Tofts' model) were to occupy approximately the same area. Since its inception, the method has been largely used in clinical environment, due to its simplicity and soundness. However, as only three time-points are used to evaluate the characteristics of the complex time-course of the contrast medium within capillaries, noise can result in voxel misclassification, as we show in this study. In this paper we analysed the performances of the method from a geometrical perspective, based on the concept of confidence region, and we proposed an 'optimal' choice of the three time-points, in order to reduce the misclassification to a minimum. Comparing the original 3TP method with our proposal on the basis of misclassification rate, our results show that the modified 3TP method can lead to better performance. Preliminary results on real data have been also reported. Moreover, our proposal has a sounding mathematical basis and is easily generalisable to the case of more than two parameters and to other modalities such as DCE-CT.

AB - The 3TP (three time points) method has been proposed for producing high-resolution pseudo-coloured maps related to the angiogenic activity in breast DCE-MRI. In the original formulation of the method, the three time-points have been chosen on an empirical basis: the algorithm for benign/malignant/uncertain classification of a voxel was to be as simple as possible and the corresponding regions of the parameters space (according to the Tofts' model) were to occupy approximately the same area. Since its inception, the method has been largely used in clinical environment, due to its simplicity and soundness. However, as only three time-points are used to evaluate the characteristics of the complex time-course of the contrast medium within capillaries, noise can result in voxel misclassification, as we show in this study. In this paper we analysed the performances of the method from a geometrical perspective, based on the concept of confidence region, and we proposed an 'optimal' choice of the three time-points, in order to reduce the misclassification to a minimum. Comparing the original 3TP method with our proposal on the basis of misclassification rate, our results show that the modified 3TP method can lead to better performance. Preliminary results on real data have been also reported. Moreover, our proposal has a sounding mathematical basis and is easily generalisable to the case of more than two parameters and to other modalities such as DCE-CT.

KW - 3TP method

KW - Confidence region

KW - DCE-MRI

KW - Nonlinear regression

KW - Optimal design

KW - Tofts model

UR - http://www.scopus.com/inward/record.url?scp=84909593096&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84909593096&partnerID=8YFLogxK

U2 - 10.1016/j.bspc.2014.10.004

DO - 10.1016/j.bspc.2014.10.004

M3 - Article

AN - SCOPUS:84909593096

VL - 16

SP - 32

EP - 39

JO - Biomedical Signal Processing and Control

JF - Biomedical Signal Processing and Control

SN - 1746-8094

ER -