A new EEG recording device demonstrating an ultra-high input impedance is presented. Dry electrodes made of conductive rubber were employed for this study with careful shielding of the electrodes and cables. The device has a small form factor, so it is wearable, and has continuous Bluetooth connectivity. Tests were performed to assess features of the proposed device and to compare it with standard clinical devices. Simultaneous EEG recordings were measured from adjacent sites on the scalp using the new EEG device with dry electrodes and a reference EEG device with standard electrodes. The gain and bandwidth settings for the two devices were set similarly. Traditional closing eyes alpha-wave replacement and mu-rhythm were compared in both the time and frequency domains. Results from eight subjects show a high correlation coefficient (0.83 on average) between recordings of contiguous dry and standard electrodes. We conclude that the performance of the new device is comparable with standard EEG recording equipment, but offers a shorter set-up time, the possibility of long-term recording, and a wireless connection - all of which are advantages valuable in the field of brain computer interfaces and neurofeedback.

Original languageEnglish
Title of host publication2008 IEEE-BIOCAS Biomedical Circuits and Systems Conference, BIOCAS 2008
Pages273-276
Number of pages4
DOIs
Publication statusPublished - 2008
Event2008 IEEE-BIOCAS Biomedical Circuits and Systems Conference, BIOCAS 2008 - Baltimore, MD, United States
Duration: Nov 20 2008Nov 22 2008

Other

Other2008 IEEE-BIOCAS Biomedical Circuits and Systems Conference, BIOCAS 2008
CountryUnited States
CityBaltimore, MD
Period11/20/0811/22/08

Fingerprint

Electroencephalography
Electrodes
Brain computer interface
Bluetooth
Shielding
Rubber
Cables
Bandwidth

Keywords

  • Bio-signal amplifier
  • Brain computer interfaces
  • Dry electrodes
  • EEG
  • Neurofeedback

ASJC Scopus subject areas

  • Biomedical Engineering
  • Control and Systems Engineering
  • Electrical and Electronic Engineering

Cite this

Gargiulo, G., Bifulco, P., Calvo, R. A., Cesarelli, M., Jin, C., & Van Schaik, A. (2008). A mobile EEG system with dry electrodes. In 2008 IEEE-BIOCAS Biomedical Circuits and Systems Conference, BIOCAS 2008 (pp. 273-276). [4696927] https://doi.org/10.1109/BIOCAS.2008.4696927

A mobile EEG system with dry electrodes. / Gargiulo, Gaetano; Bifulco, Paolo; Calvo, Rafael A.; Cesarelli, Mario; Jin, Craig; Van Schaik, André.

2008 IEEE-BIOCAS Biomedical Circuits and Systems Conference, BIOCAS 2008. 2008. p. 273-276 4696927.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Gargiulo, G, Bifulco, P, Calvo, RA, Cesarelli, M, Jin, C & Van Schaik, A 2008, A mobile EEG system with dry electrodes. in 2008 IEEE-BIOCAS Biomedical Circuits and Systems Conference, BIOCAS 2008., 4696927, pp. 273-276, 2008 IEEE-BIOCAS Biomedical Circuits and Systems Conference, BIOCAS 2008, Baltimore, MD, United States, 11/20/08. https://doi.org/10.1109/BIOCAS.2008.4696927
Gargiulo G, Bifulco P, Calvo RA, Cesarelli M, Jin C, Van Schaik A. A mobile EEG system with dry electrodes. In 2008 IEEE-BIOCAS Biomedical Circuits and Systems Conference, BIOCAS 2008. 2008. p. 273-276. 4696927 https://doi.org/10.1109/BIOCAS.2008.4696927
Gargiulo, Gaetano ; Bifulco, Paolo ; Calvo, Rafael A. ; Cesarelli, Mario ; Jin, Craig ; Van Schaik, André. / A mobile EEG system with dry electrodes. 2008 IEEE-BIOCAS Biomedical Circuits and Systems Conference, BIOCAS 2008. 2008. pp. 273-276
@inproceedings{38a1e5f67a704581becf348312f8aef1,
title = "A mobile EEG system with dry electrodes",
abstract = "A new EEG recording device demonstrating an ultra-high input impedance is presented. Dry electrodes made of conductive rubber were employed for this study with careful shielding of the electrodes and cables. The device has a small form factor, so it is wearable, and has continuous Bluetooth connectivity. Tests were performed to assess features of the proposed device and to compare it with standard clinical devices. Simultaneous EEG recordings were measured from adjacent sites on the scalp using the new EEG device with dry electrodes and a reference EEG device with standard electrodes. The gain and bandwidth settings for the two devices were set similarly. Traditional closing eyes alpha-wave replacement and mu-rhythm were compared in both the time and frequency domains. Results from eight subjects show a high correlation coefficient (0.83 on average) between recordings of contiguous dry and standard electrodes. We conclude that the performance of the new device is comparable with standard EEG recording equipment, but offers a shorter set-up time, the possibility of long-term recording, and a wireless connection - all of which are advantages valuable in the field of brain computer interfaces and neurofeedback.",
keywords = "Bio-signal amplifier, Brain computer interfaces, Dry electrodes, EEG, Neurofeedback",
author = "Gaetano Gargiulo and Paolo Bifulco and Calvo, {Rafael A.} and Mario Cesarelli and Craig Jin and {Van Schaik}, Andr{\'e}",
year = "2008",
doi = "10.1109/BIOCAS.2008.4696927",
language = "English",
isbn = "9781424428793",
pages = "273--276",
booktitle = "2008 IEEE-BIOCAS Biomedical Circuits and Systems Conference, BIOCAS 2008",

}

TY - GEN

T1 - A mobile EEG system with dry electrodes

AU - Gargiulo, Gaetano

AU - Bifulco, Paolo

AU - Calvo, Rafael A.

AU - Cesarelli, Mario

AU - Jin, Craig

AU - Van Schaik, André

PY - 2008

Y1 - 2008

N2 - A new EEG recording device demonstrating an ultra-high input impedance is presented. Dry electrodes made of conductive rubber were employed for this study with careful shielding of the electrodes and cables. The device has a small form factor, so it is wearable, and has continuous Bluetooth connectivity. Tests were performed to assess features of the proposed device and to compare it with standard clinical devices. Simultaneous EEG recordings were measured from adjacent sites on the scalp using the new EEG device with dry electrodes and a reference EEG device with standard electrodes. The gain and bandwidth settings for the two devices were set similarly. Traditional closing eyes alpha-wave replacement and mu-rhythm were compared in both the time and frequency domains. Results from eight subjects show a high correlation coefficient (0.83 on average) between recordings of contiguous dry and standard electrodes. We conclude that the performance of the new device is comparable with standard EEG recording equipment, but offers a shorter set-up time, the possibility of long-term recording, and a wireless connection - all of which are advantages valuable in the field of brain computer interfaces and neurofeedback.

AB - A new EEG recording device demonstrating an ultra-high input impedance is presented. Dry electrodes made of conductive rubber were employed for this study with careful shielding of the electrodes and cables. The device has a small form factor, so it is wearable, and has continuous Bluetooth connectivity. Tests were performed to assess features of the proposed device and to compare it with standard clinical devices. Simultaneous EEG recordings were measured from adjacent sites on the scalp using the new EEG device with dry electrodes and a reference EEG device with standard electrodes. The gain and bandwidth settings for the two devices were set similarly. Traditional closing eyes alpha-wave replacement and mu-rhythm were compared in both the time and frequency domains. Results from eight subjects show a high correlation coefficient (0.83 on average) between recordings of contiguous dry and standard electrodes. We conclude that the performance of the new device is comparable with standard EEG recording equipment, but offers a shorter set-up time, the possibility of long-term recording, and a wireless connection - all of which are advantages valuable in the field of brain computer interfaces and neurofeedback.

KW - Bio-signal amplifier

KW - Brain computer interfaces

KW - Dry electrodes

KW - EEG

KW - Neurofeedback

UR - http://www.scopus.com/inward/record.url?scp=63649146137&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=63649146137&partnerID=8YFLogxK

U2 - 10.1109/BIOCAS.2008.4696927

DO - 10.1109/BIOCAS.2008.4696927

M3 - Conference contribution

AN - SCOPUS:63649146137

SN - 9781424428793

SP - 273

EP - 276

BT - 2008 IEEE-BIOCAS Biomedical Circuits and Systems Conference, BIOCAS 2008

ER -