A new sensory feedback system for lower-limb amputees: Assessment of discrete vibrotactile stimuli perception during walking

Mariangela Filosa, Ilaria Cesini, Elena Martini, Giacomo Spigler, Nicola Vitiello, Calogero Oddo, Simona Crea

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

Sensory feedback systems can improve gait performance of lower-limb amputees by providing information about the foot-ground interaction force. This study presents a new platform designed to deliver bilateral vibrations on the waist of the user, synchronously with specific gait events. Preliminary perceptual tests were carried out on five healthy subjects to investigate the perception thresholds on the abdominal region. The reaction time and the percentage of correct perceptions were computed to compare three stimulation levels: 50%, 70% and 100% of the maximum vibration amplitude (i.e., 1.5 g, 1.9 g and 2.2 g). The reaction times decreased with higher activation levels. The percentage of correct perceptions was 40% with 50% stimulation level and higher than 97% with 70% and 100% stimulation levels, respectively. The results suggest that vibration amplitudes of 1.9 g provide vibrotactile stimulation that can be effectively perceived during walking, thus used to convey sensory information.

LanguageEnglish
Title of host publicationBiosystems and Biorobotics
PublisherSpringer International Publishing AG
Pages105-109
Number of pages5
DOIs
Publication statusPublished - Jan 1 2019

Publication series

NameBiosystems and Biorobotics
Volume22
ISSN (Print)2195-3562
ISSN (Electronic)2195-3570

Fingerprint

Sensory feedback
Chemical activation

ASJC Scopus subject areas

  • Biomedical Engineering
  • Mechanical Engineering
  • Artificial Intelligence

Cite this

Filosa, M., Cesini, I., Martini, E., Spigler, G., Vitiello, N., Oddo, C., & Crea, S. (2019). A new sensory feedback system for lower-limb amputees: Assessment of discrete vibrotactile stimuli perception during walking. In Biosystems and Biorobotics (pp. 105-109). (Biosystems and Biorobotics; Vol. 22). Springer International Publishing AG. https://doi.org/10.1007/978-3-030-01887-0_21

A new sensory feedback system for lower-limb amputees : Assessment of discrete vibrotactile stimuli perception during walking. / Filosa, Mariangela; Cesini, Ilaria; Martini, Elena; Spigler, Giacomo; Vitiello, Nicola; Oddo, Calogero; Crea, Simona.

Biosystems and Biorobotics. Springer International Publishing AG, 2019. p. 105-109 (Biosystems and Biorobotics; Vol. 22).

Research output: Chapter in Book/Report/Conference proceedingChapter

Filosa, M, Cesini, I, Martini, E, Spigler, G, Vitiello, N, Oddo, C & Crea, S 2019, A new sensory feedback system for lower-limb amputees: Assessment of discrete vibrotactile stimuli perception during walking. in Biosystems and Biorobotics. Biosystems and Biorobotics, vol. 22, Springer International Publishing AG, pp. 105-109. https://doi.org/10.1007/978-3-030-01887-0_21
Filosa M, Cesini I, Martini E, Spigler G, Vitiello N, Oddo C et al. A new sensory feedback system for lower-limb amputees: Assessment of discrete vibrotactile stimuli perception during walking. In Biosystems and Biorobotics. Springer International Publishing AG. 2019. p. 105-109. (Biosystems and Biorobotics). https://doi.org/10.1007/978-3-030-01887-0_21
Filosa, Mariangela ; Cesini, Ilaria ; Martini, Elena ; Spigler, Giacomo ; Vitiello, Nicola ; Oddo, Calogero ; Crea, Simona. / A new sensory feedback system for lower-limb amputees : Assessment of discrete vibrotactile stimuli perception during walking. Biosystems and Biorobotics. Springer International Publishing AG, 2019. pp. 105-109 (Biosystems and Biorobotics).
@inbook{0cb59aab81d14661aaf50031ea137606,
title = "A new sensory feedback system for lower-limb amputees: Assessment of discrete vibrotactile stimuli perception during walking",
abstract = "Sensory feedback systems can improve gait performance of lower-limb amputees by providing information about the foot-ground interaction force. This study presents a new platform designed to deliver bilateral vibrations on the waist of the user, synchronously with specific gait events. Preliminary perceptual tests were carried out on five healthy subjects to investigate the perception thresholds on the abdominal region. The reaction time and the percentage of correct perceptions were computed to compare three stimulation levels: 50{\%}, 70{\%} and 100{\%} of the maximum vibration amplitude (i.e., 1.5 g, 1.9 g and 2.2 g). The reaction times decreased with higher activation levels. The percentage of correct perceptions was 40{\%} with 50{\%} stimulation level and higher than 97{\%} with 70{\%} and 100{\%} stimulation levels, respectively. The results suggest that vibration amplitudes of 1.9 g provide vibrotactile stimulation that can be effectively perceived during walking, thus used to convey sensory information.",
author = "Mariangela Filosa and Ilaria Cesini and Elena Martini and Giacomo Spigler and Nicola Vitiello and Calogero Oddo and Simona Crea",
year = "2019",
month = "1",
day = "1",
doi = "10.1007/978-3-030-01887-0_21",
language = "English",
series = "Biosystems and Biorobotics",
publisher = "Springer International Publishing AG",
pages = "105--109",
booktitle = "Biosystems and Biorobotics",
address = "Switzerland",

}

TY - CHAP

T1 - A new sensory feedback system for lower-limb amputees

T2 - Assessment of discrete vibrotactile stimuli perception during walking

AU - Filosa, Mariangela

AU - Cesini, Ilaria

AU - Martini, Elena

AU - Spigler, Giacomo

AU - Vitiello, Nicola

AU - Oddo, Calogero

AU - Crea, Simona

PY - 2019/1/1

Y1 - 2019/1/1

N2 - Sensory feedback systems can improve gait performance of lower-limb amputees by providing information about the foot-ground interaction force. This study presents a new platform designed to deliver bilateral vibrations on the waist of the user, synchronously with specific gait events. Preliminary perceptual tests were carried out on five healthy subjects to investigate the perception thresholds on the abdominal region. The reaction time and the percentage of correct perceptions were computed to compare three stimulation levels: 50%, 70% and 100% of the maximum vibration amplitude (i.e., 1.5 g, 1.9 g and 2.2 g). The reaction times decreased with higher activation levels. The percentage of correct perceptions was 40% with 50% stimulation level and higher than 97% with 70% and 100% stimulation levels, respectively. The results suggest that vibration amplitudes of 1.9 g provide vibrotactile stimulation that can be effectively perceived during walking, thus used to convey sensory information.

AB - Sensory feedback systems can improve gait performance of lower-limb amputees by providing information about the foot-ground interaction force. This study presents a new platform designed to deliver bilateral vibrations on the waist of the user, synchronously with specific gait events. Preliminary perceptual tests were carried out on five healthy subjects to investigate the perception thresholds on the abdominal region. The reaction time and the percentage of correct perceptions were computed to compare three stimulation levels: 50%, 70% and 100% of the maximum vibration amplitude (i.e., 1.5 g, 1.9 g and 2.2 g). The reaction times decreased with higher activation levels. The percentage of correct perceptions was 40% with 50% stimulation level and higher than 97% with 70% and 100% stimulation levels, respectively. The results suggest that vibration amplitudes of 1.9 g provide vibrotactile stimulation that can be effectively perceived during walking, thus used to convey sensory information.

UR - http://www.scopus.com/inward/record.url?scp=85055022353&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85055022353&partnerID=8YFLogxK

U2 - 10.1007/978-3-030-01887-0_21

DO - 10.1007/978-3-030-01887-0_21

M3 - Chapter

T3 - Biosystems and Biorobotics

SP - 105

EP - 109

BT - Biosystems and Biorobotics

PB - Springer International Publishing AG

ER -