Abstract
A method for correcting the tube kinking after ascending aortic replacement for acute dissection is described. Its main advantage is the no need for cardiopulmonary by-pass (CPB) and aortic clamping to solve the problem. Copyright (C) 2000 Elsevier Science B.V.
Original language | English |
---|---|
Pages (from-to) | 611-612 |
Number of pages | 2 |
Journal | European Journal of Cardio-thoracic Surgery |
Volume | 18 |
Issue number | 5 |
DOIs | |
Publication status | Published - Nov 1 2000 |
Keywords
- Aortic dissection
- Kinking
- Surgery
ASJC Scopus subject areas
- Cardiology and Cardiovascular Medicine
- Surgery