TY - JOUR
T1 - A single-surgeon randomized trial comparing sutures, N-butyl-2- cyanoacrylate and human fibrin glue for mesh fixation during primary inguinal hernia repair
AU - Testini, Mario
AU - Lissidini, Germana
AU - Poli, Elisabetta
AU - Gurrado, Angela
AU - Lardo, Domenica
AU - Piccinni, Giuseppe
PY - 2010/6
Y1 - 2010/6
N2 - Background: We sought to determine the efficacy of sutures, human fibrin glue and N-butyl-2-cyanoacrylate for mesh fixation in patients undergoing the plug and mesh procedure for groin hernia. Methods: A total of 156 patients with 167 inguinal hernias (11 bilateral) underwent a plug and mesh procedure and were randomly assigned to received either sutures (n = 59 hernias), human fibrin glue (n = 52) or N-butyl-2-cyanoacrylate (n = 56) for mesh fixation. Results: The overall morbidity rate was 38.98% in the suture group, 9.62% in the fibrin glue group and 10.71% in the N-butyl-2-cyanoacrylate group (suture v. Fibrin glue, p <0.001; Suture v. N-butyl-2-cyanoacrylate, p <0.001). There was no significant difference in morbidity between the fibrin glue and N-butyl-2-cyanoacrylate groups. Overall, short-term morbidity was significantly higher in the suture group (27.12%) than in the fibrin glue (9.62%, p = 0.01) or N-butyl-2-cyanoacrylate (8.93%, p = 0.004) groups, but there was no significant difference between the fibrin glue and N-butyl-2-cyanoacrylate groups. There was no significant difference between the groups in terms of mean postoperative stay (32.6 h in the suture group v. 30.8 h in the fibrin glue group v. 32.0 h in the N-butyl-2-cyanoacrylate group) or mean time to return to work (20.4 d in the suture group v. 20.3 d in the fibrin glue group v. 19.8 d in the N-butyl-2-cyanoacrylate group). Overall, long-term morbidity was significantly higher in the suture group (11.86%) than in the fibrin glue (0%, p = 0.001) or N-butyl-2-cyanoacrylate (1.78%, p = 0.03) groups. There was no recurrence in any of the groups. Two cases (3.39%) of chronic groin pain were reported in patients in the suture group. A sensation of extraneous body was reported in 5 (8.47%) patients who received sutures and in 1 (1.78%) patient in the N-butyl-2-cyanoacrylate group; There were no reported cases in the fibrin glue group (suture v. Fibrin glue, p = 0.01; Suture v. N-butyl-2-cyanoacrylate, p = 0.03; Fibrin glue v. N-butyl-2-cyanoacrylate, p = 0.30). Conclusion: The use of human fibrin glue or N-butyl-2-cyanoacrylate is better tolerated than sutures in tension-free inguinal open repair using the plug and mesh technique in terms of overall immediate results, and there is a better trend in the long-term data.
AB - Background: We sought to determine the efficacy of sutures, human fibrin glue and N-butyl-2-cyanoacrylate for mesh fixation in patients undergoing the plug and mesh procedure for groin hernia. Methods: A total of 156 patients with 167 inguinal hernias (11 bilateral) underwent a plug and mesh procedure and were randomly assigned to received either sutures (n = 59 hernias), human fibrin glue (n = 52) or N-butyl-2-cyanoacrylate (n = 56) for mesh fixation. Results: The overall morbidity rate was 38.98% in the suture group, 9.62% in the fibrin glue group and 10.71% in the N-butyl-2-cyanoacrylate group (suture v. Fibrin glue, p <0.001; Suture v. N-butyl-2-cyanoacrylate, p <0.001). There was no significant difference in morbidity between the fibrin glue and N-butyl-2-cyanoacrylate groups. Overall, short-term morbidity was significantly higher in the suture group (27.12%) than in the fibrin glue (9.62%, p = 0.01) or N-butyl-2-cyanoacrylate (8.93%, p = 0.004) groups, but there was no significant difference between the fibrin glue and N-butyl-2-cyanoacrylate groups. There was no significant difference between the groups in terms of mean postoperative stay (32.6 h in the suture group v. 30.8 h in the fibrin glue group v. 32.0 h in the N-butyl-2-cyanoacrylate group) or mean time to return to work (20.4 d in the suture group v. 20.3 d in the fibrin glue group v. 19.8 d in the N-butyl-2-cyanoacrylate group). Overall, long-term morbidity was significantly higher in the suture group (11.86%) than in the fibrin glue (0%, p = 0.001) or N-butyl-2-cyanoacrylate (1.78%, p = 0.03) groups. There was no recurrence in any of the groups. Two cases (3.39%) of chronic groin pain were reported in patients in the suture group. A sensation of extraneous body was reported in 5 (8.47%) patients who received sutures and in 1 (1.78%) patient in the N-butyl-2-cyanoacrylate group; There were no reported cases in the fibrin glue group (suture v. Fibrin glue, p = 0.01; Suture v. N-butyl-2-cyanoacrylate, p = 0.03; Fibrin glue v. N-butyl-2-cyanoacrylate, p = 0.30). Conclusion: The use of human fibrin glue or N-butyl-2-cyanoacrylate is better tolerated than sutures in tension-free inguinal open repair using the plug and mesh technique in terms of overall immediate results, and there is a better trend in the long-term data.
UR - http://www.scopus.com/inward/record.url?scp=77953147429&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77953147429&partnerID=8YFLogxK
M3 - Article
C2 - 20507786
AN - SCOPUS:77953147429
VL - 53
SP - 155
EP - 160
JO - Canadian Journal of Surgery
JF - Canadian Journal of Surgery
SN - 0008-428X
IS - 3
ER -