A suitable procedure utilizing MCS 3p for peripheral blood stem cells collection (PBSCC) in a low weight patient

S. Parco, G. Bruno, A. Leopaldi, M. Durighello, R. Giorgini, M. A. Mangiarotti

Research output: Contribution to journalArticle

Abstract

We describe a suitable procedure we have utilized in a low weight patient for the collection of Peripheral Blood Stem Cells (PBSC). The technique is based on the transfusional pre-treatment of patient to reach 40% of haematocrit, on connecting the small bowl of a MCS3p (Haemonetics) separator to a red cell concentrate and on using a blood flow rate of 20 mL/min.

Original languageEnglish
Pages (from-to)303-304
Number of pages2
JournalTrasfusione del Sangue
Volume42
Issue number5
Publication statusPublished - 1997

Fingerprint

Weights and Measures
Hematocrit
Peripheral Blood Stem Cells
Therapeutics

Keywords

  • Low weight patient
  • MCS 3p
  • Peripheral blood stem cell collection (PBSC)

ASJC Scopus subject areas

  • Hematology
  • Immunology and Allergy

Cite this

Parco, S., Bruno, G., Leopaldi, A., Durighello, M., Giorgini, R., & Mangiarotti, M. A. (1997). A suitable procedure utilizing MCS 3p for peripheral blood stem cells collection (PBSCC) in a low weight patient. Trasfusione del Sangue, 42(5), 303-304.

A suitable procedure utilizing MCS 3p for peripheral blood stem cells collection (PBSCC) in a low weight patient. / Parco, S.; Bruno, G.; Leopaldi, A.; Durighello, M.; Giorgini, R.; Mangiarotti, M. A.

In: Trasfusione del Sangue, Vol. 42, No. 5, 1997, p. 303-304.

Research output: Contribution to journalArticle

Parco, S, Bruno, G, Leopaldi, A, Durighello, M, Giorgini, R & Mangiarotti, MA 1997, 'A suitable procedure utilizing MCS 3p for peripheral blood stem cells collection (PBSCC) in a low weight patient', Trasfusione del Sangue, vol. 42, no. 5, pp. 303-304.
Parco S, Bruno G, Leopaldi A, Durighello M, Giorgini R, Mangiarotti MA. A suitable procedure utilizing MCS 3p for peripheral blood stem cells collection (PBSCC) in a low weight patient. Trasfusione del Sangue. 1997;42(5):303-304.
Parco, S. ; Bruno, G. ; Leopaldi, A. ; Durighello, M. ; Giorgini, R. ; Mangiarotti, M. A. / A suitable procedure utilizing MCS 3p for peripheral blood stem cells collection (PBSCC) in a low weight patient. In: Trasfusione del Sangue. 1997 ; Vol. 42, No. 5. pp. 303-304.
@article{d5092a2df6f8479990bea39e092fe73d,
title = "A suitable procedure utilizing MCS 3p for peripheral blood stem cells collection (PBSCC) in a low weight patient",
abstract = "We describe a suitable procedure we have utilized in a low weight patient for the collection of Peripheral Blood Stem Cells (PBSC). The technique is based on the transfusional pre-treatment of patient to reach 40{\%} of haematocrit, on connecting the small bowl of a MCS3p (Haemonetics) separator to a red cell concentrate and on using a blood flow rate of 20 mL/min.",
keywords = "Low weight patient, MCS 3p, Peripheral blood stem cell collection (PBSC)",
author = "S. Parco and G. Bruno and A. Leopaldi and M. Durighello and R. Giorgini and Mangiarotti, {M. A.}",
year = "1997",
language = "English",
volume = "42",
pages = "303--304",
journal = "Trasfusione del Sangue",
issn = "0041-1787",
publisher = "SIMTI Servizi",
number = "5",

}

TY - JOUR

T1 - A suitable procedure utilizing MCS 3p for peripheral blood stem cells collection (PBSCC) in a low weight patient

AU - Parco, S.

AU - Bruno, G.

AU - Leopaldi, A.

AU - Durighello, M.

AU - Giorgini, R.

AU - Mangiarotti, M. A.

PY - 1997

Y1 - 1997

N2 - We describe a suitable procedure we have utilized in a low weight patient for the collection of Peripheral Blood Stem Cells (PBSC). The technique is based on the transfusional pre-treatment of patient to reach 40% of haematocrit, on connecting the small bowl of a MCS3p (Haemonetics) separator to a red cell concentrate and on using a blood flow rate of 20 mL/min.

AB - We describe a suitable procedure we have utilized in a low weight patient for the collection of Peripheral Blood Stem Cells (PBSC). The technique is based on the transfusional pre-treatment of patient to reach 40% of haematocrit, on connecting the small bowl of a MCS3p (Haemonetics) separator to a red cell concentrate and on using a blood flow rate of 20 mL/min.

KW - Low weight patient

KW - MCS 3p

KW - Peripheral blood stem cell collection (PBSC)

UR - http://www.scopus.com/inward/record.url?scp=0031452976&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031452976&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0031452976

VL - 42

SP - 303

EP - 304

JO - Trasfusione del Sangue

JF - Trasfusione del Sangue

SN - 0041-1787

IS - 5

ER -