The aim of this research was to evaluate the Ergovision Screener (ES) accuracy e validity by a confrontation with the conventional ophthalmic check (OC), for the medical evaluation of job fitness. A population of 100 VDU operators was considered. Each subject underwent randomly both the ES and the ophthalmic check visit. Several test carried out by the Ergovision Screener were not consistent with the conventional ophthalmic check. In a number of cases, high false positive ratio have been found, which could lead to unnecessary further examinations. For all these reasons we believe that the ES is not an appropriate instrument for the medical evaluation of job fitness.

Original languageItalian
Pages (from-to)250-251
Number of pages2
JournalGiornale Italiano di Medicina del Lavoro ed Ergonomia
Volume29
Issue number3
Publication statusPublished - Jul 2007

Fingerprint

Research
Population

ASJC Scopus subject areas

  • Public Health, Environmental and Occupational Health
  • Rehabilitation

Cite this

Adeguatezza e affidabilità dell'ortoanalizzatore ergovision nel giudizio di idoneità specifica. / Totaro, B.; Assini, R.; Consonni, D.; Guzzi, C.; Troiano, P.; Dal Pozzo, R.; D'Orso, M.; Bergamaschi, A.; Piccoli, B.

In: Giornale Italiano di Medicina del Lavoro ed Ergonomia, Vol. 29, No. 3, 07.2007, p. 250-251.

Research output: Contribution to journalArticle

Totaro, B, Assini, R, Consonni, D, Guzzi, C, Troiano, P, Dal Pozzo, R, D'Orso, M, Bergamaschi, A & Piccoli, B 2007, 'Adeguatezza e affidabilità dell'ortoanalizzatore ergovision nel giudizio di idoneità specifica', Giornale Italiano di Medicina del Lavoro ed Ergonomia, vol. 29, no. 3, pp. 250-251.
Totaro, B. ; Assini, R. ; Consonni, D. ; Guzzi, C. ; Troiano, P. ; Dal Pozzo, R. ; D'Orso, M. ; Bergamaschi, A. ; Piccoli, B. / Adeguatezza e affidabilità dell'ortoanalizzatore ergovision nel giudizio di idoneità specifica. In: Giornale Italiano di Medicina del Lavoro ed Ergonomia. 2007 ; Vol. 29, No. 3. pp. 250-251.
@article{dc78f9c5a9934fc2bde83df590ec5494,
title = "Adeguatezza e affidabilit{\`a} dell'ortoanalizzatore ergovision nel giudizio di idoneit{\`a} specifica",
abstract = "The aim of this research was to evaluate the Ergovision Screener (ES) accuracy e validity by a confrontation with the conventional ophthalmic check (OC), for the medical evaluation of job fitness. A population of 100 VDU operators was considered. Each subject underwent randomly both the ES and the ophthalmic check visit. Several test carried out by the Ergovision Screener were not consistent with the conventional ophthalmic check. In a number of cases, high false positive ratio have been found, which could lead to unnecessary further examinations. For all these reasons we believe that the ES is not an appropriate instrument for the medical evaluation of job fitness.",
keywords = "Ergovision screener, Job fitness, VDU",
author = "B. Totaro and R. Assini and D. Consonni and C. Guzzi and P. Troiano and {Dal Pozzo}, R. and M. D'Orso and A. Bergamaschi and B. Piccoli",
year = "2007",
month = "7",
language = "Italian",
volume = "29",
pages = "250--251",
journal = "Giornale Italiano di Medicina del Lavoro ed Ergonomia",
issn = "1592-7830",
publisher = "Tipografia PI-ME Editrice Srl",
number = "3",

}

TY - JOUR

T1 - Adeguatezza e affidabilità dell'ortoanalizzatore ergovision nel giudizio di idoneità specifica

AU - Totaro, B.

AU - Assini, R.

AU - Consonni, D.

AU - Guzzi, C.

AU - Troiano, P.

AU - Dal Pozzo, R.

AU - D'Orso, M.

AU - Bergamaschi, A.

AU - Piccoli, B.

PY - 2007/7

Y1 - 2007/7

N2 - The aim of this research was to evaluate the Ergovision Screener (ES) accuracy e validity by a confrontation with the conventional ophthalmic check (OC), for the medical evaluation of job fitness. A population of 100 VDU operators was considered. Each subject underwent randomly both the ES and the ophthalmic check visit. Several test carried out by the Ergovision Screener were not consistent with the conventional ophthalmic check. In a number of cases, high false positive ratio have been found, which could lead to unnecessary further examinations. For all these reasons we believe that the ES is not an appropriate instrument for the medical evaluation of job fitness.

AB - The aim of this research was to evaluate the Ergovision Screener (ES) accuracy e validity by a confrontation with the conventional ophthalmic check (OC), for the medical evaluation of job fitness. A population of 100 VDU operators was considered. Each subject underwent randomly both the ES and the ophthalmic check visit. Several test carried out by the Ergovision Screener were not consistent with the conventional ophthalmic check. In a number of cases, high false positive ratio have been found, which could lead to unnecessary further examinations. For all these reasons we believe that the ES is not an appropriate instrument for the medical evaluation of job fitness.

KW - Ergovision screener

KW - Job fitness

KW - VDU

UR - http://www.scopus.com/inward/record.url?scp=39349099539&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=39349099539&partnerID=8YFLogxK

M3 - Articolo

C2 - 18409670

AN - SCOPUS:39349099539

VL - 29

SP - 250

EP - 251

JO - Giornale Italiano di Medicina del Lavoro ed Ergonomia

JF - Giornale Italiano di Medicina del Lavoro ed Ergonomia

SN - 1592-7830

IS - 3

ER -