Adherence to European Society of Gastrointestinal Endoscopy recommendations of endoscopists performing small bowel capsule endoscopy in Italy

Emanuele Rondonotti, Cristiano Spada, Marco Pennazio, Roberto de Franchis, Sergio Cadoni, Carlo Girelli, Cesare Hassan, Riccardo Marmo, Maria Elena Riccioni, Giuseppe Scarpulla, Marco Soncini, Maurizio Vecchi, Renato Cannizzaro

Research output: Contribution to journalArticle

Abstract

Background: The European Society of Gastrointestinal Endoscopy (ESGE) has recently issued a technical review focused on small bowel capsule endoscopy (SBCE). Aim: To compare SBCE current practice in Italy to ESGE technical recommendations. Material and methods: A dedicated per-centre semi-quantitative questionnaire was prepared by a group of SBCE experts. One-hundred-fifty Centres were invited to participate in the data collection concerning SBCEs performed between June 2016 and June 2017. Data were compared with ESGE recommendations. Results: 120 Centres participated in the data collection. Current practices agreed with ESGE recommendations in 56.3% (9/16) of the issues evaluated. Differences between ESGE recommendations and current practice concerned the management of patients with pacemakers or cardiac implantable defibrillators (which was in agreement with ESGE recommendations in 31.7% and 15.8% of Centres, respectively), the SBCE setting (only 51% of SBCEs were performed as outpatients procedures), the assessment of capsule excretion (timing and modality were in agreement with ESGE recommendation in 20.0% of Centres), and in the involvement of trained nurses or fellows in training as pre-readers (7/120; 5.8%). Conclusions: Although SBCE is widely used and largely available in Italy, there are still some technical, practical and organizational issues that can be modified to bridge the gap between current practice and ESGE guideline recommendations.

LanguageEnglish
JournalDigestive and Liver Disease
DOIs
Publication statusAccepted/In press - Jan 1 2019

Keywords

  • Complications
  • Quality assurance
  • Small bowel capsule endoscopy
  • Technical guidelines

ASJC Scopus subject areas

  • Hepatology
  • Gastroenterology

Cite this

Adherence to European Society of Gastrointestinal Endoscopy recommendations of endoscopists performing small bowel capsule endoscopy in Italy. / Rondonotti, Emanuele; Spada, Cristiano; Pennazio, Marco; de Franchis, Roberto; Cadoni, Sergio; Girelli, Carlo; Hassan, Cesare; Marmo, Riccardo; Riccioni, Maria Elena; Scarpulla, Giuseppe; Soncini, Marco; Vecchi, Maurizio; Cannizzaro, Renato.

In: Digestive and Liver Disease, 01.01.2019.

Research output: Contribution to journalArticle

Rondonotti, Emanuele ; Spada, Cristiano ; Pennazio, Marco ; de Franchis, Roberto ; Cadoni, Sergio ; Girelli, Carlo ; Hassan, Cesare ; Marmo, Riccardo ; Riccioni, Maria Elena ; Scarpulla, Giuseppe ; Soncini, Marco ; Vecchi, Maurizio ; Cannizzaro, Renato. / Adherence to European Society of Gastrointestinal Endoscopy recommendations of endoscopists performing small bowel capsule endoscopy in Italy. In: Digestive and Liver Disease. 2019.
@article{992a3345c4774b0d9a12926c92b8b991,
title = "Adherence to European Society of Gastrointestinal Endoscopy recommendations of endoscopists performing small bowel capsule endoscopy in Italy",
abstract = "Background: The European Society of Gastrointestinal Endoscopy (ESGE) has recently issued a technical review focused on small bowel capsule endoscopy (SBCE). Aim: To compare SBCE current practice in Italy to ESGE technical recommendations. Material and methods: A dedicated per-centre semi-quantitative questionnaire was prepared by a group of SBCE experts. One-hundred-fifty Centres were invited to participate in the data collection concerning SBCEs performed between June 2016 and June 2017. Data were compared with ESGE recommendations. Results: 120 Centres participated in the data collection. Current practices agreed with ESGE recommendations in 56.3{\%} (9/16) of the issues evaluated. Differences between ESGE recommendations and current practice concerned the management of patients with pacemakers or cardiac implantable defibrillators (which was in agreement with ESGE recommendations in 31.7{\%} and 15.8{\%} of Centres, respectively), the SBCE setting (only 51{\%} of SBCEs were performed as outpatients procedures), the assessment of capsule excretion (timing and modality were in agreement with ESGE recommendation in 20.0{\%} of Centres), and in the involvement of trained nurses or fellows in training as pre-readers (7/120; 5.8{\%}). Conclusions: Although SBCE is widely used and largely available in Italy, there are still some technical, practical and organizational issues that can be modified to bridge the gap between current practice and ESGE guideline recommendations.",
keywords = "Complications, Quality assurance, Small bowel capsule endoscopy, Technical guidelines",
author = "Emanuele Rondonotti and Cristiano Spada and Marco Pennazio and {de Franchis}, Roberto and Sergio Cadoni and Carlo Girelli and Cesare Hassan and Riccardo Marmo and Riccioni, {Maria Elena} and Giuseppe Scarpulla and Marco Soncini and Maurizio Vecchi and Renato Cannizzaro",
year = "2019",
month = "1",
day = "1",
doi = "10.1016/j.dld.2018.11.031",
language = "English",
journal = "Digestive and Liver Disease",
issn = "1590-8658",
publisher = "Elsevier B.V.",

}

TY - JOUR

T1 - Adherence to European Society of Gastrointestinal Endoscopy recommendations of endoscopists performing small bowel capsule endoscopy in Italy

AU - Rondonotti, Emanuele

AU - Spada, Cristiano

AU - Pennazio, Marco

AU - de Franchis, Roberto

AU - Cadoni, Sergio

AU - Girelli, Carlo

AU - Hassan, Cesare

AU - Marmo, Riccardo

AU - Riccioni, Maria Elena

AU - Scarpulla, Giuseppe

AU - Soncini, Marco

AU - Vecchi, Maurizio

AU - Cannizzaro, Renato

PY - 2019/1/1

Y1 - 2019/1/1

N2 - Background: The European Society of Gastrointestinal Endoscopy (ESGE) has recently issued a technical review focused on small bowel capsule endoscopy (SBCE). Aim: To compare SBCE current practice in Italy to ESGE technical recommendations. Material and methods: A dedicated per-centre semi-quantitative questionnaire was prepared by a group of SBCE experts. One-hundred-fifty Centres were invited to participate in the data collection concerning SBCEs performed between June 2016 and June 2017. Data were compared with ESGE recommendations. Results: 120 Centres participated in the data collection. Current practices agreed with ESGE recommendations in 56.3% (9/16) of the issues evaluated. Differences between ESGE recommendations and current practice concerned the management of patients with pacemakers or cardiac implantable defibrillators (which was in agreement with ESGE recommendations in 31.7% and 15.8% of Centres, respectively), the SBCE setting (only 51% of SBCEs were performed as outpatients procedures), the assessment of capsule excretion (timing and modality were in agreement with ESGE recommendation in 20.0% of Centres), and in the involvement of trained nurses or fellows in training as pre-readers (7/120; 5.8%). Conclusions: Although SBCE is widely used and largely available in Italy, there are still some technical, practical and organizational issues that can be modified to bridge the gap between current practice and ESGE guideline recommendations.

AB - Background: The European Society of Gastrointestinal Endoscopy (ESGE) has recently issued a technical review focused on small bowel capsule endoscopy (SBCE). Aim: To compare SBCE current practice in Italy to ESGE technical recommendations. Material and methods: A dedicated per-centre semi-quantitative questionnaire was prepared by a group of SBCE experts. One-hundred-fifty Centres were invited to participate in the data collection concerning SBCEs performed between June 2016 and June 2017. Data were compared with ESGE recommendations. Results: 120 Centres participated in the data collection. Current practices agreed with ESGE recommendations in 56.3% (9/16) of the issues evaluated. Differences between ESGE recommendations and current practice concerned the management of patients with pacemakers or cardiac implantable defibrillators (which was in agreement with ESGE recommendations in 31.7% and 15.8% of Centres, respectively), the SBCE setting (only 51% of SBCEs were performed as outpatients procedures), the assessment of capsule excretion (timing and modality were in agreement with ESGE recommendation in 20.0% of Centres), and in the involvement of trained nurses or fellows in training as pre-readers (7/120; 5.8%). Conclusions: Although SBCE is widely used and largely available in Italy, there are still some technical, practical and organizational issues that can be modified to bridge the gap between current practice and ESGE guideline recommendations.

KW - Complications

KW - Quality assurance

KW - Small bowel capsule endoscopy

KW - Technical guidelines

UR - http://www.scopus.com/inward/record.url?scp=85059679702&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85059679702&partnerID=8YFLogxK

U2 - 10.1016/j.dld.2018.11.031

DO - 10.1016/j.dld.2018.11.031

M3 - Article

JO - Digestive and Liver Disease

T2 - Digestive and Liver Disease

JF - Digestive and Liver Disease

SN - 1590-8658

ER -