Advances in assessing myotonia: Can sensor-engineered glove have a role?

Simona Portaro, Margherita Russo, Antonino Naro, Alessia Bramanti, Placido Bramanti, Carmelo Rodolico, Rocco Salvatore Calabrò

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Non-dystrophic (NDMs) and Dystrophic Myotonias (DMs) are diseases characterized by the presence of myotonia with or without muscle weakness. A standardized myotonia assessment is important to more objectively quantify the handgrip myotonia. We screened 10 patients affected by NDM and 10 patients with DM, using the sensor-engineered glove (SEG). The time required to perform a complete finger extension (grip myotonia time, GMT) at maximum velocity (MV) after maximum voluntary contraction (MVC) was evaluated through an ad hoc protocol including rest, exercise, and ice effects on handgrip myotonia. We observed a general trend to GMT increase when applying the ice block and a GMT decrease when repeating GM movements, at individual level in both NDM and DM patients. SEG is an automated, non-invasive, quick, and easy technique for evaluating handgrip myotonia in NDM and DM patients. SEG could, therefore, be considered a promising tool to evaluate myotonia and monitor treatment efficacy for clinical trials.

Original languageEnglish
Pages (from-to)3-7
Number of pages5
JournalJournal of the Neurological Sciences
Volume375
DOIs
Publication statusPublished - Apr 15 2017

Fingerprint

Myotonia
Hand Strength
Ice
Muscle Weakness
Fingers
Clinical Trials
Exercise

Keywords

  • Adolescent
  • Adult
  • Biomedical Engineering
  • Diagnostic Techniques, Neurological
  • Equipment and Supplies
  • Female
  • Hand Strength
  • Humans
  • Male
  • Middle Aged
  • Muscle Contraction
  • Muscle, Skeletal
  • Myotonia
  • Young Adult
  • Journal Article

Cite this

Advances in assessing myotonia: Can sensor-engineered glove have a role? / Portaro, Simona; Russo, Margherita; Naro, Antonino; Bramanti, Alessia; Bramanti, Placido; Rodolico, Carmelo; Calabrò, Rocco Salvatore.

In: Journal of the Neurological Sciences, Vol. 375, 15.04.2017, p. 3-7.

Research output: Contribution to journalArticle

@article{598bc710a24a4e7c8c17f76828c9d15e,
title = "Advances in assessing myotonia: Can sensor-engineered glove have a role?",
abstract = "Non-dystrophic (NDMs) and Dystrophic Myotonias (DMs) are diseases characterized by the presence of myotonia with or without muscle weakness. A standardized myotonia assessment is important to more objectively quantify the handgrip myotonia. We screened 10 patients affected by NDM and 10 patients with DM, using the sensor-engineered glove (SEG). The time required to perform a complete finger extension (grip myotonia time, GMT) at maximum velocity (MV) after maximum voluntary contraction (MVC) was evaluated through an ad hoc protocol including rest, exercise, and ice effects on handgrip myotonia. We observed a general trend to GMT increase when applying the ice block and a GMT decrease when repeating GM movements, at individual level in both NDM and DM patients. SEG is an automated, non-invasive, quick, and easy technique for evaluating handgrip myotonia in NDM and DM patients. SEG could, therefore, be considered a promising tool to evaluate myotonia and monitor treatment efficacy for clinical trials.",
keywords = "Adolescent, Adult, Biomedical Engineering, Diagnostic Techniques, Neurological, Equipment and Supplies, Female, Hand Strength, Humans, Male, Middle Aged, Muscle Contraction, Muscle, Skeletal, Myotonia, Young Adult, Journal Article",
author = "Simona Portaro and Margherita Russo and Antonino Naro and Alessia Bramanti and Placido Bramanti and Carmelo Rodolico and Calabr{\`o}, {Rocco Salvatore}",
note = "Copyright {\circledC} 2017 Elsevier B.V. All rights reserved.",
year = "2017",
month = "4",
day = "15",
doi = "10.1016/j.jns.2017.01.038",
language = "English",
volume = "375",
pages = "3--7",
journal = "Journal of the Neurological Sciences",
issn = "0022-510X",
publisher = "Elsevier",

}

TY - JOUR

T1 - Advances in assessing myotonia: Can sensor-engineered glove have a role?

AU - Portaro, Simona

AU - Russo, Margherita

AU - Naro, Antonino

AU - Bramanti, Alessia

AU - Bramanti, Placido

AU - Rodolico, Carmelo

AU - Calabrò, Rocco Salvatore

N1 - Copyright © 2017 Elsevier B.V. All rights reserved.

PY - 2017/4/15

Y1 - 2017/4/15

N2 - Non-dystrophic (NDMs) and Dystrophic Myotonias (DMs) are diseases characterized by the presence of myotonia with or without muscle weakness. A standardized myotonia assessment is important to more objectively quantify the handgrip myotonia. We screened 10 patients affected by NDM and 10 patients with DM, using the sensor-engineered glove (SEG). The time required to perform a complete finger extension (grip myotonia time, GMT) at maximum velocity (MV) after maximum voluntary contraction (MVC) was evaluated through an ad hoc protocol including rest, exercise, and ice effects on handgrip myotonia. We observed a general trend to GMT increase when applying the ice block and a GMT decrease when repeating GM movements, at individual level in both NDM and DM patients. SEG is an automated, non-invasive, quick, and easy technique for evaluating handgrip myotonia in NDM and DM patients. SEG could, therefore, be considered a promising tool to evaluate myotonia and monitor treatment efficacy for clinical trials.

AB - Non-dystrophic (NDMs) and Dystrophic Myotonias (DMs) are diseases characterized by the presence of myotonia with or without muscle weakness. A standardized myotonia assessment is important to more objectively quantify the handgrip myotonia. We screened 10 patients affected by NDM and 10 patients with DM, using the sensor-engineered glove (SEG). The time required to perform a complete finger extension (grip myotonia time, GMT) at maximum velocity (MV) after maximum voluntary contraction (MVC) was evaluated through an ad hoc protocol including rest, exercise, and ice effects on handgrip myotonia. We observed a general trend to GMT increase when applying the ice block and a GMT decrease when repeating GM movements, at individual level in both NDM and DM patients. SEG is an automated, non-invasive, quick, and easy technique for evaluating handgrip myotonia in NDM and DM patients. SEG could, therefore, be considered a promising tool to evaluate myotonia and monitor treatment efficacy for clinical trials.

KW - Adolescent

KW - Adult

KW - Biomedical Engineering

KW - Diagnostic Techniques, Neurological

KW - Equipment and Supplies

KW - Female

KW - Hand Strength

KW - Humans

KW - Male

KW - Middle Aged

KW - Muscle Contraction

KW - Muscle, Skeletal

KW - Myotonia

KW - Young Adult

KW - Journal Article

U2 - 10.1016/j.jns.2017.01.038

DO - 10.1016/j.jns.2017.01.038

M3 - Article

VL - 375

SP - 3

EP - 7

JO - Journal of the Neurological Sciences