An innovative CCD-based high-resolution CT system for analysis of trabecular bone tissue

F. Baruffaldi, M. Bettuzzi, D. Bianconi, R. Brancaccio, S. Cornacchia, N. Lanconelli, L. Mancini, M. P. Morigi, A. Pasini, E. Perilli, D. Romani, A. Rossi, F. Casali

Research output: Contribution to journalArticle

Abstract

Synchrotron-based digital radiography and microtomography devices are powerful, nondestructive, high-resolution research tools. In this paper, we present a linear system with a pixel size of 22.5 μm and a fleld-of-view (FOV) 13 cm long and about 1 mm high. The system is composed of a linear converter GOS screen coupled to an intensified electron-bombarded CCD (EBCCD) camera, by means of a rectangular-to-linear fiber optic adapter. This optical guide is composed of seven bundles, each one transporting light in a coherent way to preserve spatial information. In this way, a high spatial resolution over an extended FOV is obtained. The detector works as an X-ray scanner by means of a high-precision translation mechanical device with 18 cm travel range. The total FOV obtained this way is 13 cm long and 18 cm high. The aim of this paper is to demonstrate the feasibility of this system to investigate a large area of a bone and to calculate the appropriate histomorphometric parameters. Here we present an investigation gained at ELETTRA synchrotron facility at Trieste, Italy. A monochromatic 34-keV beam has been used for imaging a human proximal femur, about 9 cm in width, with our system. The reconstructed images (13 cm × 13 cm) were cross sections containing femoral head, femoral neck, and greater trochanter. The local variations in trabecular and cortical structure of the examined bone were clearly visible at a level not obtainable with medical CT scanners. The used spatial resolution allowed the visualization of thin trabeculae, which typically lie in a range of 100 μm or lower. The quality of the reconstructed cross-section images confirmed that the system presented is a novel tool for high resolution three-dimensional (3-D) imaging of bone structure, with a pixel size over a volume of interest not achievable with conventional microCT scanners.

Original languageEnglish
Article number1710242
Pages (from-to)2584-2590
Number of pages7
JournalIEEE Transactions on Nuclear Science
Volume53
Issue number5
DOIs
Publication statusPublished - Oct 2006

Fingerprint

Charge coupled devices
bones
scanners
charge coupled devices
Bone
Tissue
Synchrotrons
high resolution
synchrotrons
spatial resolution
Pixels
pixels
adapters
mechanical devices
Imaging techniques
femur
Radiography
cross sections
radiography
CCD cameras

Keywords

  • Biomedical
  • X-ray detectors
  • X-ray tomography

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Nuclear Energy and Engineering

Cite this

Baruffaldi, F., Bettuzzi, M., Bianconi, D., Brancaccio, R., Cornacchia, S., Lanconelli, N., ... Casali, F. (2006). An innovative CCD-based high-resolution CT system for analysis of trabecular bone tissue. IEEE Transactions on Nuclear Science, 53(5), 2584-2590. [1710242]. https://doi.org/10.1109/TNS.2006.876047

An innovative CCD-based high-resolution CT system for analysis of trabecular bone tissue. / Baruffaldi, F.; Bettuzzi, M.; Bianconi, D.; Brancaccio, R.; Cornacchia, S.; Lanconelli, N.; Mancini, L.; Morigi, M. P.; Pasini, A.; Perilli, E.; Romani, D.; Rossi, A.; Casali, F.

In: IEEE Transactions on Nuclear Science, Vol. 53, No. 5, 1710242, 10.2006, p. 2584-2590.

Research output: Contribution to journalArticle

Baruffaldi, F, Bettuzzi, M, Bianconi, D, Brancaccio, R, Cornacchia, S, Lanconelli, N, Mancini, L, Morigi, MP, Pasini, A, Perilli, E, Romani, D, Rossi, A & Casali, F 2006, 'An innovative CCD-based high-resolution CT system for analysis of trabecular bone tissue', IEEE Transactions on Nuclear Science, vol. 53, no. 5, 1710242, pp. 2584-2590. https://doi.org/10.1109/TNS.2006.876047
Baruffaldi, F. ; Bettuzzi, M. ; Bianconi, D. ; Brancaccio, R. ; Cornacchia, S. ; Lanconelli, N. ; Mancini, L. ; Morigi, M. P. ; Pasini, A. ; Perilli, E. ; Romani, D. ; Rossi, A. ; Casali, F. / An innovative CCD-based high-resolution CT system for analysis of trabecular bone tissue. In: IEEE Transactions on Nuclear Science. 2006 ; Vol. 53, No. 5. pp. 2584-2590.
@article{73b9b4837c4e4992bac2cc6da4e40936,
title = "An innovative CCD-based high-resolution CT system for analysis of trabecular bone tissue",
abstract = "Synchrotron-based digital radiography and microtomography devices are powerful, nondestructive, high-resolution research tools. In this paper, we present a linear system with a pixel size of 22.5 μm and a fleld-of-view (FOV) 13 cm long and about 1 mm high. The system is composed of a linear converter GOS screen coupled to an intensified electron-bombarded CCD (EBCCD) camera, by means of a rectangular-to-linear fiber optic adapter. This optical guide is composed of seven bundles, each one transporting light in a coherent way to preserve spatial information. In this way, a high spatial resolution over an extended FOV is obtained. The detector works as an X-ray scanner by means of a high-precision translation mechanical device with 18 cm travel range. The total FOV obtained this way is 13 cm long and 18 cm high. The aim of this paper is to demonstrate the feasibility of this system to investigate a large area of a bone and to calculate the appropriate histomorphometric parameters. Here we present an investigation gained at ELETTRA synchrotron facility at Trieste, Italy. A monochromatic 34-keV beam has been used for imaging a human proximal femur, about 9 cm in width, with our system. The reconstructed images (13 cm × 13 cm) were cross sections containing femoral head, femoral neck, and greater trochanter. The local variations in trabecular and cortical structure of the examined bone were clearly visible at a level not obtainable with medical CT scanners. The used spatial resolution allowed the visualization of thin trabeculae, which typically lie in a range of 100 μm or lower. The quality of the reconstructed cross-section images confirmed that the system presented is a novel tool for high resolution three-dimensional (3-D) imaging of bone structure, with a pixel size over a volume of interest not achievable with conventional microCT scanners.",
keywords = "Biomedical, X-ray detectors, X-ray tomography",
author = "F. Baruffaldi and M. Bettuzzi and D. Bianconi and R. Brancaccio and S. Cornacchia and N. Lanconelli and L. Mancini and Morigi, {M. P.} and A. Pasini and E. Perilli and D. Romani and A. Rossi and F. Casali",
year = "2006",
month = "10",
doi = "10.1109/TNS.2006.876047",
language = "English",
volume = "53",
pages = "2584--2590",
journal = "IEEE Transactions on Nuclear Science",
issn = "0018-9499",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "5",

}

TY - JOUR

T1 - An innovative CCD-based high-resolution CT system for analysis of trabecular bone tissue

AU - Baruffaldi, F.

AU - Bettuzzi, M.

AU - Bianconi, D.

AU - Brancaccio, R.

AU - Cornacchia, S.

AU - Lanconelli, N.

AU - Mancini, L.

AU - Morigi, M. P.

AU - Pasini, A.

AU - Perilli, E.

AU - Romani, D.

AU - Rossi, A.

AU - Casali, F.

PY - 2006/10

Y1 - 2006/10

N2 - Synchrotron-based digital radiography and microtomography devices are powerful, nondestructive, high-resolution research tools. In this paper, we present a linear system with a pixel size of 22.5 μm and a fleld-of-view (FOV) 13 cm long and about 1 mm high. The system is composed of a linear converter GOS screen coupled to an intensified electron-bombarded CCD (EBCCD) camera, by means of a rectangular-to-linear fiber optic adapter. This optical guide is composed of seven bundles, each one transporting light in a coherent way to preserve spatial information. In this way, a high spatial resolution over an extended FOV is obtained. The detector works as an X-ray scanner by means of a high-precision translation mechanical device with 18 cm travel range. The total FOV obtained this way is 13 cm long and 18 cm high. The aim of this paper is to demonstrate the feasibility of this system to investigate a large area of a bone and to calculate the appropriate histomorphometric parameters. Here we present an investigation gained at ELETTRA synchrotron facility at Trieste, Italy. A monochromatic 34-keV beam has been used for imaging a human proximal femur, about 9 cm in width, with our system. The reconstructed images (13 cm × 13 cm) were cross sections containing femoral head, femoral neck, and greater trochanter. The local variations in trabecular and cortical structure of the examined bone were clearly visible at a level not obtainable with medical CT scanners. The used spatial resolution allowed the visualization of thin trabeculae, which typically lie in a range of 100 μm or lower. The quality of the reconstructed cross-section images confirmed that the system presented is a novel tool for high resolution three-dimensional (3-D) imaging of bone structure, with a pixel size over a volume of interest not achievable with conventional microCT scanners.

AB - Synchrotron-based digital radiography and microtomography devices are powerful, nondestructive, high-resolution research tools. In this paper, we present a linear system with a pixel size of 22.5 μm and a fleld-of-view (FOV) 13 cm long and about 1 mm high. The system is composed of a linear converter GOS screen coupled to an intensified electron-bombarded CCD (EBCCD) camera, by means of a rectangular-to-linear fiber optic adapter. This optical guide is composed of seven bundles, each one transporting light in a coherent way to preserve spatial information. In this way, a high spatial resolution over an extended FOV is obtained. The detector works as an X-ray scanner by means of a high-precision translation mechanical device with 18 cm travel range. The total FOV obtained this way is 13 cm long and 18 cm high. The aim of this paper is to demonstrate the feasibility of this system to investigate a large area of a bone and to calculate the appropriate histomorphometric parameters. Here we present an investigation gained at ELETTRA synchrotron facility at Trieste, Italy. A monochromatic 34-keV beam has been used for imaging a human proximal femur, about 9 cm in width, with our system. The reconstructed images (13 cm × 13 cm) were cross sections containing femoral head, femoral neck, and greater trochanter. The local variations in trabecular and cortical structure of the examined bone were clearly visible at a level not obtainable with medical CT scanners. The used spatial resolution allowed the visualization of thin trabeculae, which typically lie in a range of 100 μm or lower. The quality of the reconstructed cross-section images confirmed that the system presented is a novel tool for high resolution three-dimensional (3-D) imaging of bone structure, with a pixel size over a volume of interest not achievable with conventional microCT scanners.

KW - Biomedical

KW - X-ray detectors

KW - X-ray tomography

UR - http://www.scopus.com/inward/record.url?scp=33750383282&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33750383282&partnerID=8YFLogxK

U2 - 10.1109/TNS.2006.876047

DO - 10.1109/TNS.2006.876047

M3 - Article

AN - SCOPUS:33750383282

VL - 53

SP - 2584

EP - 2590

JO - IEEE Transactions on Nuclear Science

JF - IEEE Transactions on Nuclear Science

SN - 0018-9499

IS - 5

M1 - 1710242

ER -