Analysis of implantable cardioverter defibrillator signals for non conventional cardiac electrical activity characterization

Aldo Casaleggio, Paolo Rossi, Andrea Faini, Tiziana Guidotto, Vincenzo Malavasi, Giacomo Musso, Giuseppe Sartori

Research output: Contribution to journalArticle

Abstract

Implantable cardioverter defibrillators (ICDs) can store intracardiac electrograms (EGMs) in sinus rhythm (SR), at the onset of spontaneous ventricular tachyarrhythmias (VT) or during their course. This allows the investigation of unknown features of the heart electrical activity associated with different cardiac rhythms. In this study we propose a non conventional cardiac electrical activity characterization (CEAC) that extracts quantitative information about the power spectrum wideness and variability of the beat-by-beat morphology. We analyze 293 EGMs from 40 patients who underwent implantation of St Jude Medical-Ventritex ICDs that allow the storage of EGMs with two different modes of recording: bipolar (BIP) and unipolar or far-field (FF). The EGMs are studied with this CEAC by (1) exploring differences between the CEAC measured from FF and BIP EGMs during similar cardiac rhythms, and (2) investigating the mode of recording that allows a better separation between SR and VT rhythms. Results show that, with similar cardiac rhythm, the CEACs from FF or BIP recordings are different (for SR rhythm: sensitivity 81.5%, specificity 93.6%; for VT rhythm: sensitivity and specificity 100%); thus FF and BIP EGMs analyze different aspects of cardiac activity.The CEAC applied to FF EGMs distinguishes better EGMs obtained during SR from VT rhythms (VT vs SR with sensitivity 92.7% and specificity 79.7%) than when it is applied to BIP signals (VT vs SR with sensitivity 60% and specificity 73.3%).

Original languageEnglish
Pages (from-to)45-53
Number of pages9
JournalMedical and Biological Engineering and Computing
Volume44
Issue number1-2
DOIs
Publication statusPublished - Mar 2006

Fingerprint

Implantable cardioverter defibrillators
Implantable Defibrillators
Tachycardia
Sensitivity and Specificity
Power spectrum
Cardiac Electrophysiologic Techniques

Keywords

  • Cardiac electrical activity characterization
  • Correlation dimension
  • Implantable cardioverter defibrillator
  • Intracardiac electrograms
  • Power spectrum
  • Ventricular tachyarrhythmias

ASJC Scopus subject areas

  • Biomedical Engineering
  • Health Informatics
  • Health Information Management
  • Computer Science Applications
  • Computational Theory and Mathematics

Cite this

Analysis of implantable cardioverter defibrillator signals for non conventional cardiac electrical activity characterization. / Casaleggio, Aldo; Rossi, Paolo; Faini, Andrea; Guidotto, Tiziana; Malavasi, Vincenzo; Musso, Giacomo; Sartori, Giuseppe.

In: Medical and Biological Engineering and Computing, Vol. 44, No. 1-2, 03.2006, p. 45-53.

Research output: Contribution to journalArticle

Casaleggio, Aldo ; Rossi, Paolo ; Faini, Andrea ; Guidotto, Tiziana ; Malavasi, Vincenzo ; Musso, Giacomo ; Sartori, Giuseppe. / Analysis of implantable cardioverter defibrillator signals for non conventional cardiac electrical activity characterization. In: Medical and Biological Engineering and Computing. 2006 ; Vol. 44, No. 1-2. pp. 45-53.
@article{c7e137fc250a44cfb0f65b9feacadefd,
title = "Analysis of implantable cardioverter defibrillator signals for non conventional cardiac electrical activity characterization",
abstract = "Implantable cardioverter defibrillators (ICDs) can store intracardiac electrograms (EGMs) in sinus rhythm (SR), at the onset of spontaneous ventricular tachyarrhythmias (VT) or during their course. This allows the investigation of unknown features of the heart electrical activity associated with different cardiac rhythms. In this study we propose a non conventional cardiac electrical activity characterization (CEAC) that extracts quantitative information about the power spectrum wideness and variability of the beat-by-beat morphology. We analyze 293 EGMs from 40 patients who underwent implantation of St Jude Medical-Ventritex ICDs that allow the storage of EGMs with two different modes of recording: bipolar (BIP) and unipolar or far-field (FF). The EGMs are studied with this CEAC by (1) exploring differences between the CEAC measured from FF and BIP EGMs during similar cardiac rhythms, and (2) investigating the mode of recording that allows a better separation between SR and VT rhythms. Results show that, with similar cardiac rhythm, the CEACs from FF or BIP recordings are different (for SR rhythm: sensitivity 81.5{\%}, specificity 93.6{\%}; for VT rhythm: sensitivity and specificity 100{\%}); thus FF and BIP EGMs analyze different aspects of cardiac activity.The CEAC applied to FF EGMs distinguishes better EGMs obtained during SR from VT rhythms (VT vs SR with sensitivity 92.7{\%} and specificity 79.7{\%}) than when it is applied to BIP signals (VT vs SR with sensitivity 60{\%} and specificity 73.3{\%}).",
keywords = "Cardiac electrical activity characterization, Correlation dimension, Implantable cardioverter defibrillator, Intracardiac electrograms, Power spectrum, Ventricular tachyarrhythmias",
author = "Aldo Casaleggio and Paolo Rossi and Andrea Faini and Tiziana Guidotto and Vincenzo Malavasi and Giacomo Musso and Giuseppe Sartori",
year = "2006",
month = "3",
doi = "10.1007/s11517-005-0014-0",
language = "English",
volume = "44",
pages = "45--53",
journal = "Medical and Biological Engineering and Computing",
issn = "0140-0118",
publisher = "Springer Verlag",
number = "1-2",

}

TY - JOUR

T1 - Analysis of implantable cardioverter defibrillator signals for non conventional cardiac electrical activity characterization

AU - Casaleggio, Aldo

AU - Rossi, Paolo

AU - Faini, Andrea

AU - Guidotto, Tiziana

AU - Malavasi, Vincenzo

AU - Musso, Giacomo

AU - Sartori, Giuseppe

PY - 2006/3

Y1 - 2006/3

N2 - Implantable cardioverter defibrillators (ICDs) can store intracardiac electrograms (EGMs) in sinus rhythm (SR), at the onset of spontaneous ventricular tachyarrhythmias (VT) or during their course. This allows the investigation of unknown features of the heart electrical activity associated with different cardiac rhythms. In this study we propose a non conventional cardiac electrical activity characterization (CEAC) that extracts quantitative information about the power spectrum wideness and variability of the beat-by-beat morphology. We analyze 293 EGMs from 40 patients who underwent implantation of St Jude Medical-Ventritex ICDs that allow the storage of EGMs with two different modes of recording: bipolar (BIP) and unipolar or far-field (FF). The EGMs are studied with this CEAC by (1) exploring differences between the CEAC measured from FF and BIP EGMs during similar cardiac rhythms, and (2) investigating the mode of recording that allows a better separation between SR and VT rhythms. Results show that, with similar cardiac rhythm, the CEACs from FF or BIP recordings are different (for SR rhythm: sensitivity 81.5%, specificity 93.6%; for VT rhythm: sensitivity and specificity 100%); thus FF and BIP EGMs analyze different aspects of cardiac activity.The CEAC applied to FF EGMs distinguishes better EGMs obtained during SR from VT rhythms (VT vs SR with sensitivity 92.7% and specificity 79.7%) than when it is applied to BIP signals (VT vs SR with sensitivity 60% and specificity 73.3%).

AB - Implantable cardioverter defibrillators (ICDs) can store intracardiac electrograms (EGMs) in sinus rhythm (SR), at the onset of spontaneous ventricular tachyarrhythmias (VT) or during their course. This allows the investigation of unknown features of the heart electrical activity associated with different cardiac rhythms. In this study we propose a non conventional cardiac electrical activity characterization (CEAC) that extracts quantitative information about the power spectrum wideness and variability of the beat-by-beat morphology. We analyze 293 EGMs from 40 patients who underwent implantation of St Jude Medical-Ventritex ICDs that allow the storage of EGMs with two different modes of recording: bipolar (BIP) and unipolar or far-field (FF). The EGMs are studied with this CEAC by (1) exploring differences between the CEAC measured from FF and BIP EGMs during similar cardiac rhythms, and (2) investigating the mode of recording that allows a better separation between SR and VT rhythms. Results show that, with similar cardiac rhythm, the CEACs from FF or BIP recordings are different (for SR rhythm: sensitivity 81.5%, specificity 93.6%; for VT rhythm: sensitivity and specificity 100%); thus FF and BIP EGMs analyze different aspects of cardiac activity.The CEAC applied to FF EGMs distinguishes better EGMs obtained during SR from VT rhythms (VT vs SR with sensitivity 92.7% and specificity 79.7%) than when it is applied to BIP signals (VT vs SR with sensitivity 60% and specificity 73.3%).

KW - Cardiac electrical activity characterization

KW - Correlation dimension

KW - Implantable cardioverter defibrillator

KW - Intracardiac electrograms

KW - Power spectrum

KW - Ventricular tachyarrhythmias

UR - http://www.scopus.com/inward/record.url?scp=33745445329&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33745445329&partnerID=8YFLogxK

U2 - 10.1007/s11517-005-0014-0

DO - 10.1007/s11517-005-0014-0

M3 - Article

C2 - 16929920

AN - SCOPUS:33745445329

VL - 44

SP - 45

EP - 53

JO - Medical and Biological Engineering and Computing

JF - Medical and Biological Engineering and Computing

SN - 0140-0118

IS - 1-2

ER -