Anisotropic damage model for evaluation of load carrying capacity of artificial ligaments

Pasquale Vena, Tomaso Villa, Roberto Contro

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Anisotropic damage model for evaluation of load carrying capacity of artificial ligaments was studied. Three samples of artificial ligaments were subjected to mechanical testing. A sensitivity analysis of the maximum load with respect to model parameters exhibited the suitability of constitutive relation for numerical calculation of load carrying capacity of the artificial ligaments.

Original languageEnglish
Title of host publicationAmerican Society of Mechanical Engineers, Bioengineering Division (Publication) BED
EditorsR.D. Kamm, G.W. Schmid-Schoenbein, G.A. Atesian, M.S. Hefzy
Pages909-910
Number of pages2
Volume50
Publication statusPublished - 2001
EventProceedings of the 2001 Bioengineering Conference - Snowbird, UT, United States
Duration: Jun 27 2001Jul 1 2001

Other

OtherProceedings of the 2001 Bioengineering Conference
CountryUnited States
CitySnowbird, UT
Period6/27/017/1/01

Fingerprint

Ligaments
Load limits
Mechanical testing
Sensitivity analysis

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Vena, P., Villa, T., & Contro, R. (2001). Anisotropic damage model for evaluation of load carrying capacity of artificial ligaments. In R. D. Kamm, G. W. Schmid-Schoenbein, G. A. Atesian, & M. S. Hefzy (Eds.), American Society of Mechanical Engineers, Bioengineering Division (Publication) BED (Vol. 50, pp. 909-910)

Anisotropic damage model for evaluation of load carrying capacity of artificial ligaments. / Vena, Pasquale; Villa, Tomaso; Contro, Roberto.

American Society of Mechanical Engineers, Bioengineering Division (Publication) BED. ed. / R.D. Kamm; G.W. Schmid-Schoenbein; G.A. Atesian; M.S. Hefzy. Vol. 50 2001. p. 909-910.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Vena, P, Villa, T & Contro, R 2001, Anisotropic damage model for evaluation of load carrying capacity of artificial ligaments. in RD Kamm, GW Schmid-Schoenbein, GA Atesian & MS Hefzy (eds), American Society of Mechanical Engineers, Bioengineering Division (Publication) BED. vol. 50, pp. 909-910, Proceedings of the 2001 Bioengineering Conference, Snowbird, UT, United States, 6/27/01.
Vena P, Villa T, Contro R. Anisotropic damage model for evaluation of load carrying capacity of artificial ligaments. In Kamm RD, Schmid-Schoenbein GW, Atesian GA, Hefzy MS, editors, American Society of Mechanical Engineers, Bioengineering Division (Publication) BED. Vol. 50. 2001. p. 909-910
Vena, Pasquale ; Villa, Tomaso ; Contro, Roberto. / Anisotropic damage model for evaluation of load carrying capacity of artificial ligaments. American Society of Mechanical Engineers, Bioengineering Division (Publication) BED. editor / R.D. Kamm ; G.W. Schmid-Schoenbein ; G.A. Atesian ; M.S. Hefzy. Vol. 50 2001. pp. 909-910
@inproceedings{e3c73e1517d546b390af883673d68586,
title = "Anisotropic damage model for evaluation of load carrying capacity of artificial ligaments",
abstract = "Anisotropic damage model for evaluation of load carrying capacity of artificial ligaments was studied. Three samples of artificial ligaments were subjected to mechanical testing. A sensitivity analysis of the maximum load with respect to model parameters exhibited the suitability of constitutive relation for numerical calculation of load carrying capacity of the artificial ligaments.",
author = "Pasquale Vena and Tomaso Villa and Roberto Contro",
year = "2001",
language = "English",
volume = "50",
pages = "909--910",
editor = "R.D. Kamm and G.W. Schmid-Schoenbein and G.A. Atesian and M.S. Hefzy",
booktitle = "American Society of Mechanical Engineers, Bioengineering Division (Publication) BED",

}

TY - GEN

T1 - Anisotropic damage model for evaluation of load carrying capacity of artificial ligaments

AU - Vena, Pasquale

AU - Villa, Tomaso

AU - Contro, Roberto

PY - 2001

Y1 - 2001

N2 - Anisotropic damage model for evaluation of load carrying capacity of artificial ligaments was studied. Three samples of artificial ligaments were subjected to mechanical testing. A sensitivity analysis of the maximum load with respect to model parameters exhibited the suitability of constitutive relation for numerical calculation of load carrying capacity of the artificial ligaments.

AB - Anisotropic damage model for evaluation of load carrying capacity of artificial ligaments was studied. Three samples of artificial ligaments were subjected to mechanical testing. A sensitivity analysis of the maximum load with respect to model parameters exhibited the suitability of constitutive relation for numerical calculation of load carrying capacity of the artificial ligaments.

UR - http://www.scopus.com/inward/record.url?scp=0242609270&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0242609270&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:0242609270

VL - 50

SP - 909

EP - 910

BT - American Society of Mechanical Engineers, Bioengineering Division (Publication) BED

A2 - Kamm, R.D.

A2 - Schmid-Schoenbein, G.W.

A2 - Atesian, G.A.

A2 - Hefzy, M.S.

ER -