Are the tubular grafts in the femoral tunnel in an anatomical or isometric position in the reconstruction of medial patellofemoral ligament?

Panagiotis G. Ntagiopoulos, Bharat Sharma, Simone Bignozzi, Nicola Lopomo, Francesca Colle, Stefano Zaffagnini, David Dejour

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

Purpose: The purpose of this study was to evaluate the biomechanical results from the in vitro reconstruction of medial patellofemoral ligament (MPFL) using a navigation-assisted technique on a cadaveric model and its effects on patellar stability and kinematics. The authors investigated the hypothesis that patellar kinematics after reconstruction with a tubular graft are not optimal when compared with the original fan-shaped MPFL. Methods: In six fresh-frozen cadaveric knees, lateral loads (25 N) were applied on the patella at 0, 30, 60 and 90 of knee flexion in three different MPFL states: intact, cut and reconstructed. The arrangement allowed positional measurements of patellar motion to be tracked in six degrees of freedom. Medial to lateral patellar translation and patellar tilt were recorded. The kinematics after a technique of MPFL reconstruction, performed with a gracilis tendon in a blind femoral tunnel guided by navigation, were compared against kinematics recorded in the MPFL intact state. A temporary fixation of adequate tension to engage the lateral patellar facet in extension was applied to the MPFL and, after graft cycling, the final fixation was done at 70 knee flexion with an interference screw. Results: There was a comparable medial to lateral patellar translation and tilting of the patella in the MPFL-intact and the MPFL-reconstructed state. Static patellar translation in the MPFL-reconstructed state, with and without the application of load, was comparable to patellar translation in the MPFL-intact state. The dynamic patellofemoral shift kinematics recorded an under-constraint in early flexion and over-constraint in late flexion, while an opposite effect was recorded in patellar tilt. However, these differences were not statistically significant. Conclusion: The study confirmed the major role of the MPFL in case of medial loading between 0 and 60, by focusing on the importance of kinematically identifying the proper femoral point for fixation. While the study demonstrates the importance of kinematic determination of the proper femoral point of fixation, as the anatomical insertion remains difficult to identify. Even in dissected cadavers, the authors recorded a slightly anterior placement than native MPFL. After reconstruction, patellar stability in terms of lateral translation and tilt was similar to the intact MPFL, but patellar kinematics were not optimal with the use of a smaller and tubular graft than the native wider and fan-shaped MPFL.

Original languageEnglish
Pages (from-to)1933-1941
Number of pages9
JournalInternational Orthopaedics
Volume37
Issue number10
DOIs
Publication statusPublished - Oct 2013

Fingerprint

Thigh
Ligaments
Transplants
Biomechanical Phenomena
Knee
Patella
Patellar Ligament
Cadaver
Tendons

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

Are the tubular grafts in the femoral tunnel in an anatomical or isometric position in the reconstruction of medial patellofemoral ligament? / Ntagiopoulos, Panagiotis G.; Sharma, Bharat; Bignozzi, Simone; Lopomo, Nicola; Colle, Francesca; Zaffagnini, Stefano; Dejour, David.

In: International Orthopaedics, Vol. 37, No. 10, 10.2013, p. 1933-1941.

Research output: Contribution to journalArticle

Ntagiopoulos, Panagiotis G. ; Sharma, Bharat ; Bignozzi, Simone ; Lopomo, Nicola ; Colle, Francesca ; Zaffagnini, Stefano ; Dejour, David. / Are the tubular grafts in the femoral tunnel in an anatomical or isometric position in the reconstruction of medial patellofemoral ligament?. In: International Orthopaedics. 2013 ; Vol. 37, No. 10. pp. 1933-1941.
@article{d149f38143f1446b9ff0d866f506b65a,
title = "Are the tubular grafts in the femoral tunnel in an anatomical or isometric position in the reconstruction of medial patellofemoral ligament?",
abstract = "Purpose: The purpose of this study was to evaluate the biomechanical results from the in vitro reconstruction of medial patellofemoral ligament (MPFL) using a navigation-assisted technique on a cadaveric model and its effects on patellar stability and kinematics. The authors investigated the hypothesis that patellar kinematics after reconstruction with a tubular graft are not optimal when compared with the original fan-shaped MPFL. Methods: In six fresh-frozen cadaveric knees, lateral loads (25 N) were applied on the patella at 0, 30, 60 and 90 of knee flexion in three different MPFL states: intact, cut and reconstructed. The arrangement allowed positional measurements of patellar motion to be tracked in six degrees of freedom. Medial to lateral patellar translation and patellar tilt were recorded. The kinematics after a technique of MPFL reconstruction, performed with a gracilis tendon in a blind femoral tunnel guided by navigation, were compared against kinematics recorded in the MPFL intact state. A temporary fixation of adequate tension to engage the lateral patellar facet in extension was applied to the MPFL and, after graft cycling, the final fixation was done at 70 knee flexion with an interference screw. Results: There was a comparable medial to lateral patellar translation and tilting of the patella in the MPFL-intact and the MPFL-reconstructed state. Static patellar translation in the MPFL-reconstructed state, with and without the application of load, was comparable to patellar translation in the MPFL-intact state. The dynamic patellofemoral shift kinematics recorded an under-constraint in early flexion and over-constraint in late flexion, while an opposite effect was recorded in patellar tilt. However, these differences were not statistically significant. Conclusion: The study confirmed the major role of the MPFL in case of medial loading between 0 and 60, by focusing on the importance of kinematically identifying the proper femoral point for fixation. While the study demonstrates the importance of kinematic determination of the proper femoral point of fixation, as the anatomical insertion remains difficult to identify. Even in dissected cadavers, the authors recorded a slightly anterior placement than native MPFL. After reconstruction, patellar stability in terms of lateral translation and tilt was similar to the intact MPFL, but patellar kinematics were not optimal with the use of a smaller and tubular graft than the native wider and fan-shaped MPFL.",
author = "Ntagiopoulos, {Panagiotis G.} and Bharat Sharma and Simone Bignozzi and Nicola Lopomo and Francesca Colle and Stefano Zaffagnini and David Dejour",
year = "2013",
month = "10",
doi = "10.1007/s00264-013-1938-x",
language = "English",
volume = "37",
pages = "1933--1941",
journal = "International Orthopaedics",
issn = "0341-2695",
publisher = "Springer Verlag",
number = "10",

}

TY - JOUR

T1 - Are the tubular grafts in the femoral tunnel in an anatomical or isometric position in the reconstruction of medial patellofemoral ligament?

AU - Ntagiopoulos, Panagiotis G.

AU - Sharma, Bharat

AU - Bignozzi, Simone

AU - Lopomo, Nicola

AU - Colle, Francesca

AU - Zaffagnini, Stefano

AU - Dejour, David

PY - 2013/10

Y1 - 2013/10

N2 - Purpose: The purpose of this study was to evaluate the biomechanical results from the in vitro reconstruction of medial patellofemoral ligament (MPFL) using a navigation-assisted technique on a cadaveric model and its effects on patellar stability and kinematics. The authors investigated the hypothesis that patellar kinematics after reconstruction with a tubular graft are not optimal when compared with the original fan-shaped MPFL. Methods: In six fresh-frozen cadaveric knees, lateral loads (25 N) were applied on the patella at 0, 30, 60 and 90 of knee flexion in three different MPFL states: intact, cut and reconstructed. The arrangement allowed positional measurements of patellar motion to be tracked in six degrees of freedom. Medial to lateral patellar translation and patellar tilt were recorded. The kinematics after a technique of MPFL reconstruction, performed with a gracilis tendon in a blind femoral tunnel guided by navigation, were compared against kinematics recorded in the MPFL intact state. A temporary fixation of adequate tension to engage the lateral patellar facet in extension was applied to the MPFL and, after graft cycling, the final fixation was done at 70 knee flexion with an interference screw. Results: There was a comparable medial to lateral patellar translation and tilting of the patella in the MPFL-intact and the MPFL-reconstructed state. Static patellar translation in the MPFL-reconstructed state, with and without the application of load, was comparable to patellar translation in the MPFL-intact state. The dynamic patellofemoral shift kinematics recorded an under-constraint in early flexion and over-constraint in late flexion, while an opposite effect was recorded in patellar tilt. However, these differences were not statistically significant. Conclusion: The study confirmed the major role of the MPFL in case of medial loading between 0 and 60, by focusing on the importance of kinematically identifying the proper femoral point for fixation. While the study demonstrates the importance of kinematic determination of the proper femoral point of fixation, as the anatomical insertion remains difficult to identify. Even in dissected cadavers, the authors recorded a slightly anterior placement than native MPFL. After reconstruction, patellar stability in terms of lateral translation and tilt was similar to the intact MPFL, but patellar kinematics were not optimal with the use of a smaller and tubular graft than the native wider and fan-shaped MPFL.

AB - Purpose: The purpose of this study was to evaluate the biomechanical results from the in vitro reconstruction of medial patellofemoral ligament (MPFL) using a navigation-assisted technique on a cadaveric model and its effects on patellar stability and kinematics. The authors investigated the hypothesis that patellar kinematics after reconstruction with a tubular graft are not optimal when compared with the original fan-shaped MPFL. Methods: In six fresh-frozen cadaveric knees, lateral loads (25 N) were applied on the patella at 0, 30, 60 and 90 of knee flexion in three different MPFL states: intact, cut and reconstructed. The arrangement allowed positional measurements of patellar motion to be tracked in six degrees of freedom. Medial to lateral patellar translation and patellar tilt were recorded. The kinematics after a technique of MPFL reconstruction, performed with a gracilis tendon in a blind femoral tunnel guided by navigation, were compared against kinematics recorded in the MPFL intact state. A temporary fixation of adequate tension to engage the lateral patellar facet in extension was applied to the MPFL and, after graft cycling, the final fixation was done at 70 knee flexion with an interference screw. Results: There was a comparable medial to lateral patellar translation and tilting of the patella in the MPFL-intact and the MPFL-reconstructed state. Static patellar translation in the MPFL-reconstructed state, with and without the application of load, was comparable to patellar translation in the MPFL-intact state. The dynamic patellofemoral shift kinematics recorded an under-constraint in early flexion and over-constraint in late flexion, while an opposite effect was recorded in patellar tilt. However, these differences were not statistically significant. Conclusion: The study confirmed the major role of the MPFL in case of medial loading between 0 and 60, by focusing on the importance of kinematically identifying the proper femoral point for fixation. While the study demonstrates the importance of kinematic determination of the proper femoral point of fixation, as the anatomical insertion remains difficult to identify. Even in dissected cadavers, the authors recorded a slightly anterior placement than native MPFL. After reconstruction, patellar stability in terms of lateral translation and tilt was similar to the intact MPFL, but patellar kinematics were not optimal with the use of a smaller and tubular graft than the native wider and fan-shaped MPFL.

UR - http://www.scopus.com/inward/record.url?scp=84885434479&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84885434479&partnerID=8YFLogxK

U2 - 10.1007/s00264-013-1938-x

DO - 10.1007/s00264-013-1938-x

M3 - Article

C2 - 23771189

AN - SCOPUS:84885434479

VL - 37

SP - 1933

EP - 1941

JO - International Orthopaedics

JF - International Orthopaedics

SN - 0341-2695

IS - 10

ER -