Assessment and comparison of three scatter correction techniques in single photon emission computed tomography

M. C. Gilardi, V. Bettinardi, A. Todd-Pokropek, L. Milanesi, F. Fazio

Research output: Contribution to journalArticle

47 Citations (Scopus)

Abstract

The detection of scattered radiation is recognized as one of the major sources of error in single photon emission computed tomography (SPECT). In this work three scatter correction techniques have been assessed and compared. Scatter coefficients and parameters characteristic of each technique have been calculated through Monte Carlo simulations and experimentally measured for various source geometries. Their dependence on the source/matter distribution and their spatial non-stationary have been described. Each of the three scatter correction methods has then been tested on several SPECT phantom studies. The three methods provided comparable results. Following scatter compensation, both image quality and quantitative accuracy improved. In particular a slight improvement in spatial resolution and a statistically significant increase in cold lesion contrast, hot lesion recovery coefficient, and signal/noise ratio have been demonstrated with all methods.

Original languageEnglish
Pages (from-to)1971-1979
Number of pages9
JournalJournal of Nuclear Medicine
Volume29
Issue number12
Publication statusPublished - 1988

Fingerprint

Single-Photon Emission-Computed Tomography
Research Design
Radiation

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

Assessment and comparison of three scatter correction techniques in single photon emission computed tomography. / Gilardi, M. C.; Bettinardi, V.; Todd-Pokropek, A.; Milanesi, L.; Fazio, F.

In: Journal of Nuclear Medicine, Vol. 29, No. 12, 1988, p. 1971-1979.

Research output: Contribution to journalArticle

Gilardi, M. C. ; Bettinardi, V. ; Todd-Pokropek, A. ; Milanesi, L. ; Fazio, F. / Assessment and comparison of three scatter correction techniques in single photon emission computed tomography. In: Journal of Nuclear Medicine. 1988 ; Vol. 29, No. 12. pp. 1971-1979.
@article{9ae6d8082ddf405882256b7be34bb172,
title = "Assessment and comparison of three scatter correction techniques in single photon emission computed tomography",
abstract = "The detection of scattered radiation is recognized as one of the major sources of error in single photon emission computed tomography (SPECT). In this work three scatter correction techniques have been assessed and compared. Scatter coefficients and parameters characteristic of each technique have been calculated through Monte Carlo simulations and experimentally measured for various source geometries. Their dependence on the source/matter distribution and their spatial non-stationary have been described. Each of the three scatter correction methods has then been tested on several SPECT phantom studies. The three methods provided comparable results. Following scatter compensation, both image quality and quantitative accuracy improved. In particular a slight improvement in spatial resolution and a statistically significant increase in cold lesion contrast, hot lesion recovery coefficient, and signal/noise ratio have been demonstrated with all methods.",
author = "Gilardi, {M. C.} and V. Bettinardi and A. Todd-Pokropek and L. Milanesi and F. Fazio",
year = "1988",
language = "English",
volume = "29",
pages = "1971--1979",
journal = "Journal of Nuclear Medicine",
issn = "0161-5505",
publisher = "Society of Nuclear Medicine Inc.",
number = "12",

}

TY - JOUR

T1 - Assessment and comparison of three scatter correction techniques in single photon emission computed tomography

AU - Gilardi, M. C.

AU - Bettinardi, V.

AU - Todd-Pokropek, A.

AU - Milanesi, L.

AU - Fazio, F.

PY - 1988

Y1 - 1988

N2 - The detection of scattered radiation is recognized as one of the major sources of error in single photon emission computed tomography (SPECT). In this work three scatter correction techniques have been assessed and compared. Scatter coefficients and parameters characteristic of each technique have been calculated through Monte Carlo simulations and experimentally measured for various source geometries. Their dependence on the source/matter distribution and their spatial non-stationary have been described. Each of the three scatter correction methods has then been tested on several SPECT phantom studies. The three methods provided comparable results. Following scatter compensation, both image quality and quantitative accuracy improved. In particular a slight improvement in spatial resolution and a statistically significant increase in cold lesion contrast, hot lesion recovery coefficient, and signal/noise ratio have been demonstrated with all methods.

AB - The detection of scattered radiation is recognized as one of the major sources of error in single photon emission computed tomography (SPECT). In this work three scatter correction techniques have been assessed and compared. Scatter coefficients and parameters characteristic of each technique have been calculated through Monte Carlo simulations and experimentally measured for various source geometries. Their dependence on the source/matter distribution and their spatial non-stationary have been described. Each of the three scatter correction methods has then been tested on several SPECT phantom studies. The three methods provided comparable results. Following scatter compensation, both image quality and quantitative accuracy improved. In particular a slight improvement in spatial resolution and a statistically significant increase in cold lesion contrast, hot lesion recovery coefficient, and signal/noise ratio have been demonstrated with all methods.

UR - http://www.scopus.com/inward/record.url?scp=0024207431&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024207431&partnerID=8YFLogxK

M3 - Article

C2 - 3264020

AN - SCOPUS:0024207431

VL - 29

SP - 1971

EP - 1979

JO - Journal of Nuclear Medicine

JF - Journal of Nuclear Medicine

SN - 0161-5505

IS - 12

ER -