Objective: The purpose of this article is to provide a minimal set of CBCT (Cone Beam Computerized Tomography) device-related parameters in orthodontics. Materials and methods: Benefits and limitations of the cone-beam computerized tomography imaging in orthodontics have been reviewed in order to determine and suggest the proper use of this radiographic technique. Results and conclusions: The results showed that it is possible to achieve more information from 3D CBCT imaging compare to traditional 2D imaging but there is a lack of evidence-based data of the topic and a wide consensus.

Original languageItalian
JournalMondo Ortodontico
Volume37
Issue number5 SUPPL.1
DOIs
Publication statusPublished - Dec 2012

Fingerprint

Cone-Beam Computed Tomography
Orthodontics
Prescriptions
Guidelines
Equipment and Supplies

ASJC Scopus subject areas

  • Orthodontics

Cite this

Conoscenze di base e indicazioni cliniche per una corretta prescrizione della CBCT in ortodonzia. / Perrotti, G.; De Vecchi, L.; Ferrario, S.; Politi, M.; Weinstein, R. L.

In: Mondo Ortodontico, Vol. 37, No. 5 SUPPL.1, 12.2012.

Research output: Contribution to journalArticle

Perrotti, G. ; De Vecchi, L. ; Ferrario, S. ; Politi, M. ; Weinstein, R. L. / Conoscenze di base e indicazioni cliniche per una corretta prescrizione della CBCT in ortodonzia. In: Mondo Ortodontico. 2012 ; Vol. 37, No. 5 SUPPL.1.
@article{4415f0f549d648b3969421a5fa1f5ac5,
title = "Conoscenze di base e indicazioni cliniche per una corretta prescrizione della CBCT in ortodonzia",
abstract = "Objective: The purpose of this article is to provide a minimal set of CBCT (Cone Beam Computerized Tomography) device-related parameters in orthodontics. Materials and methods: Benefits and limitations of the cone-beam computerized tomography imaging in orthodontics have been reviewed in order to determine and suggest the proper use of this radiographic technique. Results and conclusions: The results showed that it is possible to achieve more information from 3D CBCT imaging compare to traditional 2D imaging but there is a lack of evidence-based data of the topic and a wide consensus.",
keywords = "3D diagnosys, Cleft palate, Cone beam CT, Impacted teeth, Orthodontic diagnosys",
author = "G. Perrotti and {De Vecchi}, L. and S. Ferrario and M. Politi and Weinstein, {R. L.}",
year = "2012",
month = "12",
doi = "10.1016/j.mor.2012.03.004",
language = "Italian",
volume = "37",
journal = "Mondo Ortodontico",
issn = "0391-2000",
publisher = "Elsevier",
number = "5 SUPPL.1",

}

TY - JOUR

T1 - Conoscenze di base e indicazioni cliniche per una corretta prescrizione della CBCT in ortodonzia

AU - Perrotti, G.

AU - De Vecchi, L.

AU - Ferrario, S.

AU - Politi, M.

AU - Weinstein, R. L.

PY - 2012/12

Y1 - 2012/12

N2 - Objective: The purpose of this article is to provide a minimal set of CBCT (Cone Beam Computerized Tomography) device-related parameters in orthodontics. Materials and methods: Benefits and limitations of the cone-beam computerized tomography imaging in orthodontics have been reviewed in order to determine and suggest the proper use of this radiographic technique. Results and conclusions: The results showed that it is possible to achieve more information from 3D CBCT imaging compare to traditional 2D imaging but there is a lack of evidence-based data of the topic and a wide consensus.

AB - Objective: The purpose of this article is to provide a minimal set of CBCT (Cone Beam Computerized Tomography) device-related parameters in orthodontics. Materials and methods: Benefits and limitations of the cone-beam computerized tomography imaging in orthodontics have been reviewed in order to determine and suggest the proper use of this radiographic technique. Results and conclusions: The results showed that it is possible to achieve more information from 3D CBCT imaging compare to traditional 2D imaging but there is a lack of evidence-based data of the topic and a wide consensus.

KW - 3D diagnosys

KW - Cleft palate

KW - Cone beam CT

KW - Impacted teeth

KW - Orthodontic diagnosys

UR - http://www.scopus.com/inward/record.url?scp=84870552840&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84870552840&partnerID=8YFLogxK

U2 - 10.1016/j.mor.2012.03.004

DO - 10.1016/j.mor.2012.03.004

M3 - Articolo

VL - 37

JO - Mondo Ortodontico

JF - Mondo Ortodontico

SN - 0391-2000

IS - 5 SUPPL.1

ER -