T1 - Battery drain in daily practice and medium-term projections on longevity of cardioverterdefibrillators
T2 - An analysis from a remote monitoring database
AU - Boriani, Giuseppe
AU - Ritter, Philippe
AU - Biffi, Mauro
AU - Ziacchi, Matteo
AU - Diemberger, Igor
AU - Martignani, Cristian
AU - Valzania, Cinzia
AU - Valsecchi, Sergio
AU - Padeletti, Luigi
AU - Gadler, Fredrik
PY - 2016
Y1 - 2016
N2 - Aims The longevity of generators is a crucial determinant of the cost-effectiveness of therapy with implantable cardioverterdefibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-D). We evaluated the trend of devicemeasured residual battery capacity and longevity projections over 5-year follow-up.We also investigated possible factors associated with battery drain. Methods and results Data from 4851 patients in the European LATITUDEw database who were followed up for a minimum of 3 years were analysed. The factors associated with battery drain (i.e. year-to-year decrease in residual battery capacity), and thus potentially impacting on device longevity, were mainly the pacing parameters in CRT-D devices and the number of shocks delivered and diverted in both ICD and CRT-D (all P < 0.01 on linear regression analysis). Over the first 5 years, the longevity estimates provided by devices showed low intra-patient variability and increased with time. The estimates exceeded 10 years for CRT-Dand 13 and 12 years for single- and dual-chamber ICDs, respectively. In CRT-D patients, the expected patient age on replacement was 80±12 years, and the expected probability of undergoing device replacement was 63±13% for New York Heart Association (NYHA) II patients and 37±16% for NYHA III patients. For comparison, the probabilities of replacing a CRT-D lasting 5 years were 78±8 and 59±13%, respectively (both P, 0.001). Conclusion Battery drain was mainly associated with pacing output in CRT-D devices and with the number of capacitor charges in both ICD and CRT-D devices. The longevity estimates provided by the devices were consistent and conservative. According to these estimates, among CRT-D recipients a low proportion of patients should require device replacement.
AB - Aims The longevity of generators is a crucial determinant of the cost-effectiveness of therapy with implantable cardioverterdefibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-D). We evaluated the trend of devicemeasured residual battery capacity and longevity projections over 5-year follow-up.We also investigated possible factors associated with battery drain. Methods and results Data from 4851 patients in the European LATITUDEw database who were followed up for a minimum of 3 years were analysed. The factors associated with battery drain (i.e. year-to-year decrease in residual battery capacity), and thus potentially impacting on device longevity, were mainly the pacing parameters in CRT-D devices and the number of shocks delivered and diverted in both ICD and CRT-D (all P < 0.01 on linear regression analysis). Over the first 5 years, the longevity estimates provided by devices showed low intra-patient variability and increased with time. The estimates exceeded 10 years for CRT-Dand 13 and 12 years for single- and dual-chamber ICDs, respectively. In CRT-D patients, the expected patient age on replacement was 80±12 years, and the expected probability of undergoing device replacement was 63±13% for New York Heart Association (NYHA) II patients and 37±16% for NYHA III patients. For comparison, the probabilities of replacing a CRT-D lasting 5 years were 78±8 and 59±13%, respectively (both P, 0.001). Conclusion Battery drain was mainly associated with pacing output in CRT-D devices and with the number of capacitor charges in both ICD and CRT-D devices. The longevity estimates provided by the devices were consistent and conservative. According to these estimates, among CRT-D recipients a low proportion of patients should require device replacement.
KW - Battery
KW - Cardiac resynchronization therapy
KW - Implantable cardioverter-defibrillator
KW - Longevity
KW - Remote monitoring
UR - http://www.scopus.com/inward/record.url?scp=84992200626&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84992200626&partnerID=8YFLogxK
U2 - 10.1093/europace/euv436
DO - 10.1093/europace/euv436
M3 - Article
AN - SCOPUS:84992200626
VL - 18
SP - 1366
EP - 1373
JO - Europace
JF - Europace
SN - 1099-5129
IS - 9
ER -