TY - JOUR
T1 - Beat-to-beat estimation of LVET and QS2 indices of cardiac mechanics from wearable seismocardiography in ambulant subjects
AU - Di Rienzo, Marco
AU - Vaini, Emanuele
AU - Castiglioni, Paolo
AU - Meriggi, Paolo
AU - Rizzo, Francesco
PY - 2013
Y1 - 2013
N2 - Seismocardiogram (SCG) is the measure of the minute vibrations produced by the beating heart. We previously demonstrated that SCG, ECG and respiration could be recorded over the 24 h during spontaneous behavior by a smart garment, the MagIC-SCG system. In the present case study we explored the feasibility of a beat-to-beat estimation of two indices of heart contractility, the Left Ventricular Ejection Time (LVET) and the electromechanical systole (QS2) from SCG and ECG recordings obtained by the MagIC-SCG device in one subject. We considered data collected during outdoor spontaneous behavior (while sitting in the metro and in the office) and in a laboratory setting (in supine and sitting posture, and during recovery after 100 W and 140 W cycling). LVET was estimated from SCG as the time interval between the opening and closure of the aortic valve, QS2 as the time interval between the Q wave of the ECG and the closure of the aortic valve. In every condition, LVET and QS2 could be estimated on a beat-to-beat basis from the SCG collected by the smart garment. LVET and QS2 are characterized by important beat-to-beat fluctuations, with standard deviations in the same order of magnitude of RR Interval. In all settings, spectral profiles are different for LVET, QS2 and RR Interval. This suggests that the biological mechanisms impinging on the heart exert a differentiated influence on the variability of each of these three indices.
AB - Seismocardiogram (SCG) is the measure of the minute vibrations produced by the beating heart. We previously demonstrated that SCG, ECG and respiration could be recorded over the 24 h during spontaneous behavior by a smart garment, the MagIC-SCG system. In the present case study we explored the feasibility of a beat-to-beat estimation of two indices of heart contractility, the Left Ventricular Ejection Time (LVET) and the electromechanical systole (QS2) from SCG and ECG recordings obtained by the MagIC-SCG device in one subject. We considered data collected during outdoor spontaneous behavior (while sitting in the metro and in the office) and in a laboratory setting (in supine and sitting posture, and during recovery after 100 W and 140 W cycling). LVET was estimated from SCG as the time interval between the opening and closure of the aortic valve, QS2 as the time interval between the Q wave of the ECG and the closure of the aortic valve. In every condition, LVET and QS2 could be estimated on a beat-to-beat basis from the SCG collected by the smart garment. LVET and QS2 are characterized by important beat-to-beat fluctuations, with standard deviations in the same order of magnitude of RR Interval. In all settings, spectral profiles are different for LVET, QS2 and RR Interval. This suggests that the biological mechanisms impinging on the heart exert a differentiated influence on the variability of each of these three indices.
UR - http://www.scopus.com/inward/record.url?scp=84942576932&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84942576932&partnerID=8YFLogxK
U2 - 10.1109/EMBC.2013.6611173
DO - 10.1109/EMBC.2013.6611173
M3 - Article
C2 - 24111360
VL - 2013
SP - 7017
EP - 7020
JO - Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference
JF - Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference
SN - 1557-170X
ER -