Bioelectrical impedance in the evaluation of the nutritional status of hemodialyzed diabetic patients

D. Spotti, M. C. Librenti, M. Melandri, G. Slaviero, R. Quartagno, P. Vedani, V. Tagliabue, G. Pozza

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Bioelectrical impedance is a technique allowing a quick, repeatable and reliable assessment of body composition. This method was applied to detect total body water (TBW), fat (FAT) and fat-free mass (FFM) in 80 normal subjects, 65 diabetic (45 insulin-dependent [IDD], 20 non insulin-dependent [NIDD]) and 34 uremic diabetic patients (20 IDD, 14 NIDD) submitted to hemodialysis three times a week. Uremic patients were tested at the end of the dialytic session. Multivariated analysis adjusted for age, sex and disease showed the following results: body mass index (BMI) increased with age (p <0.005) and in the presence of NIDD (p <.001); TBW was lower in nephropathic patients (p <0.05) and in the female sex (p <0.0001); FFM decreased with age (p <0.005), female sex (p <0.0001 ) and in nonuremic NIDD (p <0.001). Correspondingly FAT increased with age (p <0.005), female sex (p <0.0001) and in nonuremic NIDD (p <0.001). Sixteen uremic subjects, randomly selected from both IDD and NIDD groups, tested at the beginning and at the end of the same hemodialytic session, showed a significant decrease of TBW which corresponded to the correction of their overhydratation. In our patients uremia does not seem to influence the nutritional status and the bioelectrical analysis could be applied to determine the real dry weight in hemodialyzed diabetic patients.

Original languageEnglish
Pages (from-to)172-174
Number of pages3
JournalClinical Nephrology
Volume39
Issue number3
Publication statusPublished - 1993

Fingerprint

Nutritional Status
Electric Impedance
Insulin
Body Water
Fats
Uremia
Body Composition
Renal Dialysis
Body Mass Index
Weights and Measures

Keywords

  • bioelectrical impedance
  • diabetes mellitus
  • end-stage renal disease
  • hemodialysis

ASJC Scopus subject areas

  • Nephrology

Cite this

Spotti, D., Librenti, M. C., Melandri, M., Slaviero, G., Quartagno, R., Vedani, P., ... Pozza, G. (1993). Bioelectrical impedance in the evaluation of the nutritional status of hemodialyzed diabetic patients. Clinical Nephrology, 39(3), 172-174.

Bioelectrical impedance in the evaluation of the nutritional status of hemodialyzed diabetic patients. / Spotti, D.; Librenti, M. C.; Melandri, M.; Slaviero, G.; Quartagno, R.; Vedani, P.; Tagliabue, V.; Pozza, G.

In: Clinical Nephrology, Vol. 39, No. 3, 1993, p. 172-174.

Research output: Contribution to journalArticle

Spotti, D, Librenti, MC, Melandri, M, Slaviero, G, Quartagno, R, Vedani, P, Tagliabue, V & Pozza, G 1993, 'Bioelectrical impedance in the evaluation of the nutritional status of hemodialyzed diabetic patients', Clinical Nephrology, vol. 39, no. 3, pp. 172-174.
Spotti D, Librenti MC, Melandri M, Slaviero G, Quartagno R, Vedani P et al. Bioelectrical impedance in the evaluation of the nutritional status of hemodialyzed diabetic patients. Clinical Nephrology. 1993;39(3):172-174.
Spotti, D. ; Librenti, M. C. ; Melandri, M. ; Slaviero, G. ; Quartagno, R. ; Vedani, P. ; Tagliabue, V. ; Pozza, G. / Bioelectrical impedance in the evaluation of the nutritional status of hemodialyzed diabetic patients. In: Clinical Nephrology. 1993 ; Vol. 39, No. 3. pp. 172-174.
@article{f4089d5988c14370810637223cf39917,
title = "Bioelectrical impedance in the evaluation of the nutritional status of hemodialyzed diabetic patients",
abstract = "Bioelectrical impedance is a technique allowing a quick, repeatable and reliable assessment of body composition. This method was applied to detect total body water (TBW), fat (FAT) and fat-free mass (FFM) in 80 normal subjects, 65 diabetic (45 insulin-dependent [IDD], 20 non insulin-dependent [NIDD]) and 34 uremic diabetic patients (20 IDD, 14 NIDD) submitted to hemodialysis three times a week. Uremic patients were tested at the end of the dialytic session. Multivariated analysis adjusted for age, sex and disease showed the following results: body mass index (BMI) increased with age (p <0.005) and in the presence of NIDD (p <.001); TBW was lower in nephropathic patients (p <0.05) and in the female sex (p <0.0001); FFM decreased with age (p <0.005), female sex (p <0.0001 ) and in nonuremic NIDD (p <0.001). Correspondingly FAT increased with age (p <0.005), female sex (p <0.0001) and in nonuremic NIDD (p <0.001). Sixteen uremic subjects, randomly selected from both IDD and NIDD groups, tested at the beginning and at the end of the same hemodialytic session, showed a significant decrease of TBW which corresponded to the correction of their overhydratation. In our patients uremia does not seem to influence the nutritional status and the bioelectrical analysis could be applied to determine the real dry weight in hemodialyzed diabetic patients.",
keywords = "bioelectrical impedance, diabetes mellitus, end-stage renal disease, hemodialysis",
author = "D. Spotti and Librenti, {M. C.} and M. Melandri and G. Slaviero and R. Quartagno and P. Vedani and V. Tagliabue and G. Pozza",
year = "1993",
language = "English",
volume = "39",
pages = "172--174",
journal = "Clinical Nephrology",
issn = "0301-0430",
publisher = "Dustri-Verlag Dr. Karl Feistle",
number = "3",

}

TY - JOUR

T1 - Bioelectrical impedance in the evaluation of the nutritional status of hemodialyzed diabetic patients

AU - Spotti, D.

AU - Librenti, M. C.

AU - Melandri, M.

AU - Slaviero, G.

AU - Quartagno, R.

AU - Vedani, P.

AU - Tagliabue, V.

AU - Pozza, G.

PY - 1993

Y1 - 1993

N2 - Bioelectrical impedance is a technique allowing a quick, repeatable and reliable assessment of body composition. This method was applied to detect total body water (TBW), fat (FAT) and fat-free mass (FFM) in 80 normal subjects, 65 diabetic (45 insulin-dependent [IDD], 20 non insulin-dependent [NIDD]) and 34 uremic diabetic patients (20 IDD, 14 NIDD) submitted to hemodialysis three times a week. Uremic patients were tested at the end of the dialytic session. Multivariated analysis adjusted for age, sex and disease showed the following results: body mass index (BMI) increased with age (p <0.005) and in the presence of NIDD (p <.001); TBW was lower in nephropathic patients (p <0.05) and in the female sex (p <0.0001); FFM decreased with age (p <0.005), female sex (p <0.0001 ) and in nonuremic NIDD (p <0.001). Correspondingly FAT increased with age (p <0.005), female sex (p <0.0001) and in nonuremic NIDD (p <0.001). Sixteen uremic subjects, randomly selected from both IDD and NIDD groups, tested at the beginning and at the end of the same hemodialytic session, showed a significant decrease of TBW which corresponded to the correction of their overhydratation. In our patients uremia does not seem to influence the nutritional status and the bioelectrical analysis could be applied to determine the real dry weight in hemodialyzed diabetic patients.

AB - Bioelectrical impedance is a technique allowing a quick, repeatable and reliable assessment of body composition. This method was applied to detect total body water (TBW), fat (FAT) and fat-free mass (FFM) in 80 normal subjects, 65 diabetic (45 insulin-dependent [IDD], 20 non insulin-dependent [NIDD]) and 34 uremic diabetic patients (20 IDD, 14 NIDD) submitted to hemodialysis three times a week. Uremic patients were tested at the end of the dialytic session. Multivariated analysis adjusted for age, sex and disease showed the following results: body mass index (BMI) increased with age (p <0.005) and in the presence of NIDD (p <.001); TBW was lower in nephropathic patients (p <0.05) and in the female sex (p <0.0001); FFM decreased with age (p <0.005), female sex (p <0.0001 ) and in nonuremic NIDD (p <0.001). Correspondingly FAT increased with age (p <0.005), female sex (p <0.0001) and in nonuremic NIDD (p <0.001). Sixteen uremic subjects, randomly selected from both IDD and NIDD groups, tested at the beginning and at the end of the same hemodialytic session, showed a significant decrease of TBW which corresponded to the correction of their overhydratation. In our patients uremia does not seem to influence the nutritional status and the bioelectrical analysis could be applied to determine the real dry weight in hemodialyzed diabetic patients.

KW - bioelectrical impedance

KW - diabetes mellitus

KW - end-stage renal disease

KW - hemodialysis

UR - http://www.scopus.com/inward/record.url?scp=0027394139&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027394139&partnerID=8YFLogxK

M3 - Article

C2 - 8462206

AN - SCOPUS:0027394139

VL - 39

SP - 172

EP - 174

JO - Clinical Nephrology

JF - Clinical Nephrology

SN - 0301-0430

IS - 3

ER -