Cardio-RM con tecnologia SENSE: Studio della funzionalità ventricolare e valvolare in 30 pazienti

Translated title of the contribution: Cardiac MRI with SENSE technology: Study of ventricular and valvular functionality in 30 patients

Giulio Sodani, Francesco Sciuto, Mauro Di Roma, Andrea Romagnoli, Giampaolo Novelli, Ettore Squillaci, Giovanni B. Forleo, Francesco Romeo, Orazio Schillaci, Giovanni Simonetti

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Purpose. The latest innovation in MR imaging is SENSE (SENSitivity Encoding), a technology providing an important solution for the time necessary for signal encoding. In the SENSitivity Encoding (SENSE) approach, an array of multiple, simultaneously operated receiver coils is used for signal acquisition. In particular, the efficacy of SENSE technology is able to reduce the number of phase encodings by a factor (named R factor or Reduction factor) and to evaluate the same k space with fewer readout lines obtaining higher spatial and temporal resolution. Materials and methods. An heterogeneous group of 30 patients with a variety of clinically proven diagnoses underwent Cardiac MR with SENSE technology to evaluate the technique's diagnostic efficacy. The sequences used were "Balanced" Ultrafast Gradient Echo (B-FFE) characterised by a hyperintense blood signal with multislice multiphase and single slice multiphase acquisitions. Results. In addition to reducing scan times, SENSE technology improved spatial and temporal resolution (40 frames/cardiac cycle) providing optimal dynamic evaluation of valve structures and wall kinesis. Furthermore, the use of the SENSE technique with B-FFE sequences (sB-FFE) enabled the qualitative evaluation of abnormal blood movements and transvalvular flows. Conclusions. The considerable time savings allowed by SENSE technology and the clear improvement in image quality constitute a step forward in cardiac MR imaging. The possibility of executing morphologic, dynamic, perfusional and spectroscopic studies in the same MR examination session with short acquisition times and good image quality are becoming more feasible.

Original languageItalian
Pages (from-to)1-10
Number of pages10
JournalRadiologia Medica
Volume107
Issue number1-2
Publication statusPublished - Jan 2004

Fingerprint

Technology
Kinesis
R Factors
Dyskinesias

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Sodani, G., Sciuto, F., Di Roma, M., Romagnoli, A., Novelli, G., Squillaci, E., ... Simonetti, G. (2004). Cardio-RM con tecnologia SENSE: Studio della funzionalità ventricolare e valvolare in 30 pazienti. Radiologia Medica, 107(1-2), 1-10.

Cardio-RM con tecnologia SENSE : Studio della funzionalità ventricolare e valvolare in 30 pazienti. / Sodani, Giulio; Sciuto, Francesco; Di Roma, Mauro; Romagnoli, Andrea; Novelli, Giampaolo; Squillaci, Ettore; Forleo, Giovanni B.; Romeo, Francesco; Schillaci, Orazio; Simonetti, Giovanni.

In: Radiologia Medica, Vol. 107, No. 1-2, 01.2004, p. 1-10.

Research output: Contribution to journalArticle

Sodani, G, Sciuto, F, Di Roma, M, Romagnoli, A, Novelli, G, Squillaci, E, Forleo, GB, Romeo, F, Schillaci, O & Simonetti, G 2004, 'Cardio-RM con tecnologia SENSE: Studio della funzionalità ventricolare e valvolare in 30 pazienti', Radiologia Medica, vol. 107, no. 1-2, pp. 1-10.
Sodani G, Sciuto F, Di Roma M, Romagnoli A, Novelli G, Squillaci E et al. Cardio-RM con tecnologia SENSE: Studio della funzionalità ventricolare e valvolare in 30 pazienti. Radiologia Medica. 2004 Jan;107(1-2):1-10.
Sodani, Giulio ; Sciuto, Francesco ; Di Roma, Mauro ; Romagnoli, Andrea ; Novelli, Giampaolo ; Squillaci, Ettore ; Forleo, Giovanni B. ; Romeo, Francesco ; Schillaci, Orazio ; Simonetti, Giovanni. / Cardio-RM con tecnologia SENSE : Studio della funzionalità ventricolare e valvolare in 30 pazienti. In: Radiologia Medica. 2004 ; Vol. 107, No. 1-2. pp. 1-10.
@article{d602eb250e42447e9cfb9ad343328576,
title = "Cardio-RM con tecnologia SENSE: Studio della funzionalit{\`a} ventricolare e valvolare in 30 pazienti",
abstract = "Purpose. The latest innovation in MR imaging is SENSE (SENSitivity Encoding), a technology providing an important solution for the time necessary for signal encoding. In the SENSitivity Encoding (SENSE) approach, an array of multiple, simultaneously operated receiver coils is used for signal acquisition. In particular, the efficacy of SENSE technology is able to reduce the number of phase encodings by a factor (named R factor or Reduction factor) and to evaluate the same k space with fewer readout lines obtaining higher spatial and temporal resolution. Materials and methods. An heterogeneous group of 30 patients with a variety of clinically proven diagnoses underwent Cardiac MR with SENSE technology to evaluate the technique's diagnostic efficacy. The sequences used were {"}Balanced{"} Ultrafast Gradient Echo (B-FFE) characterised by a hyperintense blood signal with multislice multiphase and single slice multiphase acquisitions. Results. In addition to reducing scan times, SENSE technology improved spatial and temporal resolution (40 frames/cardiac cycle) providing optimal dynamic evaluation of valve structures and wall kinesis. Furthermore, the use of the SENSE technique with B-FFE sequences (sB-FFE) enabled the qualitative evaluation of abnormal blood movements and transvalvular flows. Conclusions. The considerable time savings allowed by SENSE technology and the clear improvement in image quality constitute a step forward in cardiac MR imaging. The possibility of executing morphologic, dynamic, perfusional and spectroscopic studies in the same MR examination session with short acquisition times and good image quality are becoming more feasible.",
keywords = "Cardiac MRI, SENSE, Valvular functionality, Ventricular functionality",
author = "Giulio Sodani and Francesco Sciuto and {Di Roma}, Mauro and Andrea Romagnoli and Giampaolo Novelli and Ettore Squillaci and Forleo, {Giovanni B.} and Francesco Romeo and Orazio Schillaci and Giovanni Simonetti",
year = "2004",
month = "1",
language = "Italian",
volume = "107",
pages = "1--10",
journal = "Radiologia Medica",
issn = "0033-8362",
publisher = "Springer-Verlag Italia s.r.l.",
number = "1-2",

}

TY - JOUR

T1 - Cardio-RM con tecnologia SENSE

T2 - Studio della funzionalità ventricolare e valvolare in 30 pazienti

AU - Sodani, Giulio

AU - Sciuto, Francesco

AU - Di Roma, Mauro

AU - Romagnoli, Andrea

AU - Novelli, Giampaolo

AU - Squillaci, Ettore

AU - Forleo, Giovanni B.

AU - Romeo, Francesco

AU - Schillaci, Orazio

AU - Simonetti, Giovanni

PY - 2004/1

Y1 - 2004/1

N2 - Purpose. The latest innovation in MR imaging is SENSE (SENSitivity Encoding), a technology providing an important solution for the time necessary for signal encoding. In the SENSitivity Encoding (SENSE) approach, an array of multiple, simultaneously operated receiver coils is used for signal acquisition. In particular, the efficacy of SENSE technology is able to reduce the number of phase encodings by a factor (named R factor or Reduction factor) and to evaluate the same k space with fewer readout lines obtaining higher spatial and temporal resolution. Materials and methods. An heterogeneous group of 30 patients with a variety of clinically proven diagnoses underwent Cardiac MR with SENSE technology to evaluate the technique's diagnostic efficacy. The sequences used were "Balanced" Ultrafast Gradient Echo (B-FFE) characterised by a hyperintense blood signal with multislice multiphase and single slice multiphase acquisitions. Results. In addition to reducing scan times, SENSE technology improved spatial and temporal resolution (40 frames/cardiac cycle) providing optimal dynamic evaluation of valve structures and wall kinesis. Furthermore, the use of the SENSE technique with B-FFE sequences (sB-FFE) enabled the qualitative evaluation of abnormal blood movements and transvalvular flows. Conclusions. The considerable time savings allowed by SENSE technology and the clear improvement in image quality constitute a step forward in cardiac MR imaging. The possibility of executing morphologic, dynamic, perfusional and spectroscopic studies in the same MR examination session with short acquisition times and good image quality are becoming more feasible.

AB - Purpose. The latest innovation in MR imaging is SENSE (SENSitivity Encoding), a technology providing an important solution for the time necessary for signal encoding. In the SENSitivity Encoding (SENSE) approach, an array of multiple, simultaneously operated receiver coils is used for signal acquisition. In particular, the efficacy of SENSE technology is able to reduce the number of phase encodings by a factor (named R factor or Reduction factor) and to evaluate the same k space with fewer readout lines obtaining higher spatial and temporal resolution. Materials and methods. An heterogeneous group of 30 patients with a variety of clinically proven diagnoses underwent Cardiac MR with SENSE technology to evaluate the technique's diagnostic efficacy. The sequences used were "Balanced" Ultrafast Gradient Echo (B-FFE) characterised by a hyperintense blood signal with multislice multiphase and single slice multiphase acquisitions. Results. In addition to reducing scan times, SENSE technology improved spatial and temporal resolution (40 frames/cardiac cycle) providing optimal dynamic evaluation of valve structures and wall kinesis. Furthermore, the use of the SENSE technique with B-FFE sequences (sB-FFE) enabled the qualitative evaluation of abnormal blood movements and transvalvular flows. Conclusions. The considerable time savings allowed by SENSE technology and the clear improvement in image quality constitute a step forward in cardiac MR imaging. The possibility of executing morphologic, dynamic, perfusional and spectroscopic studies in the same MR examination session with short acquisition times and good image quality are becoming more feasible.

KW - Cardiac MRI

KW - SENSE

KW - Valvular functionality

KW - Ventricular functionality

UR - http://www.scopus.com/inward/record.url?scp=12144287782&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=12144287782&partnerID=8YFLogxK

M3 - Articolo

C2 - 15031692

AN - SCOPUS:12144287782

VL - 107

SP - 1

EP - 10

JO - Radiologia Medica

JF - Radiologia Medica

SN - 0033-8362

IS - 1-2

ER -