Cardiovascular CT angiography in neonates and children

Image quality and potential for radiation dose reduction with iterative image reconstruction techniques

Francesco Tricarico, Anthony M. Hlavacek, U. Joseph Schoepf, Ullrich Ebersberger, John W. Nance, Rozemarijn Vliegenthart, Young Jun Cho, J. Reid Spears, Francesco Secchi, Giancarlo Savino, Riccardo Marano, Stefan O. Schoenberg, Lorenzo Bonomo, Paul Apfaltrer

Research output: Contribution to journalArticle

38 Citations (Scopus)

Abstract

Objectives: To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions. Methods: Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated. Results: Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P <0.001), while SNR and CNR were higher (P <0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P <0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P <0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv. Conclusions: IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. Key Points: • Iterative reconstruction techniques significantly improve non-invasive cardiovascular CT in children. • Using half traditional radiation dose image quality is higher with iterative reconstruction. • Iterative reconstruction techniques may allow further radiation reductions in paediatric cardiovascular CT.

Original languageEnglish
Pages (from-to)1306-1315
Number of pages10
JournalEuropean Radiology
Volume23
Issue number5
DOIs
Publication statusPublished - May 2013

Fingerprint

Computer-Assisted Image Processing
Newborn Infant
Radiation
Electrocardiography
Pediatrics
Computed Tomography Angiography
Weights and Measures

Keywords

  • Computed tomography
  • Congenital heart disease
  • Iterative image reconstruction
  • Pediatric imaging
  • Radiation dose

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Cardiovascular CT angiography in neonates and children : Image quality and potential for radiation dose reduction with iterative image reconstruction techniques. / Tricarico, Francesco; Hlavacek, Anthony M.; Schoepf, U. Joseph; Ebersberger, Ullrich; Nance, John W.; Vliegenthart, Rozemarijn; Cho, Young Jun; Spears, J. Reid; Secchi, Francesco; Savino, Giancarlo; Marano, Riccardo; Schoenberg, Stefan O.; Bonomo, Lorenzo; Apfaltrer, Paul.

In: European Radiology, Vol. 23, No. 5, 05.2013, p. 1306-1315.

Research output: Contribution to journalArticle

Tricarico, F, Hlavacek, AM, Schoepf, UJ, Ebersberger, U, Nance, JW, Vliegenthart, R, Cho, YJ, Spears, JR, Secchi, F, Savino, G, Marano, R, Schoenberg, SO, Bonomo, L & Apfaltrer, P 2013, 'Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques', European Radiology, vol. 23, no. 5, pp. 1306-1315. https://doi.org/10.1007/s00330-012-2734-5
Tricarico, Francesco ; Hlavacek, Anthony M. ; Schoepf, U. Joseph ; Ebersberger, Ullrich ; Nance, John W. ; Vliegenthart, Rozemarijn ; Cho, Young Jun ; Spears, J. Reid ; Secchi, Francesco ; Savino, Giancarlo ; Marano, Riccardo ; Schoenberg, Stefan O. ; Bonomo, Lorenzo ; Apfaltrer, Paul. / Cardiovascular CT angiography in neonates and children : Image quality and potential for radiation dose reduction with iterative image reconstruction techniques. In: European Radiology. 2013 ; Vol. 23, No. 5. pp. 1306-1315.
@article{57cdc0665b5a44a5badc9422ce963443,
title = "Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques",
abstract = "Objectives: To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions. Methods: Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated. Results: Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P <0.001), while SNR and CNR were higher (P <0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P <0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P <0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv. Conclusions: IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. Key Points: • Iterative reconstruction techniques significantly improve non-invasive cardiovascular CT in children. • Using half traditional radiation dose image quality is higher with iterative reconstruction. • Iterative reconstruction techniques may allow further radiation reductions in paediatric cardiovascular CT.",
keywords = "Computed tomography, Congenital heart disease, Iterative image reconstruction, Pediatric imaging, Radiation dose",
author = "Francesco Tricarico and Hlavacek, {Anthony M.} and Schoepf, {U. Joseph} and Ullrich Ebersberger and Nance, {John W.} and Rozemarijn Vliegenthart and Cho, {Young Jun} and Spears, {J. Reid} and Francesco Secchi and Giancarlo Savino and Riccardo Marano and Schoenberg, {Stefan O.} and Lorenzo Bonomo and Paul Apfaltrer",
year = "2013",
month = "5",
doi = "10.1007/s00330-012-2734-5",
language = "English",
volume = "23",
pages = "1306--1315",
journal = "European Radiology",
issn = "0938-7994",
publisher = "Springer Verlag",
number = "5",

}

TY - JOUR

T1 - Cardiovascular CT angiography in neonates and children

T2 - Image quality and potential for radiation dose reduction with iterative image reconstruction techniques

AU - Tricarico, Francesco

AU - Hlavacek, Anthony M.

AU - Schoepf, U. Joseph

AU - Ebersberger, Ullrich

AU - Nance, John W.

AU - Vliegenthart, Rozemarijn

AU - Cho, Young Jun

AU - Spears, J. Reid

AU - Secchi, Francesco

AU - Savino, Giancarlo

AU - Marano, Riccardo

AU - Schoenberg, Stefan O.

AU - Bonomo, Lorenzo

AU - Apfaltrer, Paul

PY - 2013/5

Y1 - 2013/5

N2 - Objectives: To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions. Methods: Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated. Results: Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P <0.001), while SNR and CNR were higher (P <0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P <0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P <0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv. Conclusions: IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. Key Points: • Iterative reconstruction techniques significantly improve non-invasive cardiovascular CT in children. • Using half traditional radiation dose image quality is higher with iterative reconstruction. • Iterative reconstruction techniques may allow further radiation reductions in paediatric cardiovascular CT.

AB - Objectives: To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions. Methods: Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated. Results: Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P <0.001), while SNR and CNR were higher (P <0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P <0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P <0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv. Conclusions: IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. Key Points: • Iterative reconstruction techniques significantly improve non-invasive cardiovascular CT in children. • Using half traditional radiation dose image quality is higher with iterative reconstruction. • Iterative reconstruction techniques may allow further radiation reductions in paediatric cardiovascular CT.

KW - Computed tomography

KW - Congenital heart disease

KW - Iterative image reconstruction

KW - Pediatric imaging

KW - Radiation dose

UR - http://www.scopus.com/inward/record.url?scp=84877154860&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84877154860&partnerID=8YFLogxK

U2 - 10.1007/s00330-012-2734-5

DO - 10.1007/s00330-012-2734-5

M3 - Article

VL - 23

SP - 1306

EP - 1315

JO - European Radiology

JF - European Radiology

SN - 0938-7994

IS - 5

ER -