TY - JOUR
T1 - Chest CT performed with Z-axis modulation
T2 - Scanning protocol and radiation dose
AU - Kalra, Mannudeep K.
AU - Rizzo, Stefania
AU - Maher, Michael M.
AU - Halpern, Elkan F.
AU - Toth, Thomas L.
AU - Shepard, Jo Anne O
AU - Aquino, Suzanne L.
PY - 2005/10
Y1 - 2005/10
N2 - Institutional review board approval of the study protocol and waiver of informed consent were obtained. This study was compliant with the Health Insurance Portability and Accountability Act. The purpose of this study was to retrospectively assess the scanning protocol and radiation dose associated with z-axis automatic tube current modulation in multi-detector row CT scanning of the chest. Fifty-three patients (mean age, 54 years; age range, 26-77 years; 25 men, 28 women) underwent 16-detector row chest CT with z-axis modulation and noise indexes of 10.0, 12.5, and 15.0 HU. Two radiologists independently compared images acquired with z-axis modulation and fixed tube current (180-300 mA) techniques for image noise, diagnostic acceptability, and depiction of peripheral bronchovascular markings. Tube current-time product was calculated for each study. There was good interobserver agreement between the two readers (K = 0.72). Compared with the fixed tube current technique, z-axis modulation provides acceptable image noise for chest CT, with an 18% and 26% reduction in tube current-time product at 10.0- and 12.5-HU noise indexes, respectively.
AB - Institutional review board approval of the study protocol and waiver of informed consent were obtained. This study was compliant with the Health Insurance Portability and Accountability Act. The purpose of this study was to retrospectively assess the scanning protocol and radiation dose associated with z-axis automatic tube current modulation in multi-detector row CT scanning of the chest. Fifty-three patients (mean age, 54 years; age range, 26-77 years; 25 men, 28 women) underwent 16-detector row chest CT with z-axis modulation and noise indexes of 10.0, 12.5, and 15.0 HU. Two radiologists independently compared images acquired with z-axis modulation and fixed tube current (180-300 mA) techniques for image noise, diagnostic acceptability, and depiction of peripheral bronchovascular markings. Tube current-time product was calculated for each study. There was good interobserver agreement between the two readers (K = 0.72). Compared with the fixed tube current technique, z-axis modulation provides acceptable image noise for chest CT, with an 18% and 26% reduction in tube current-time product at 10.0- and 12.5-HU noise indexes, respectively.
UR - http://www.scopus.com/inward/record.url?scp=25144448621&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=25144448621&partnerID=8YFLogxK
U2 - 10.1148/radiol.2371041227
DO - 10.1148/radiol.2371041227
M3 - Article
C2 - 16183938
AN - SCOPUS:25144448621
VL - 237
SP - 303
EP - 308
JO - Radiology
JF - Radiology
SN - 0033-8419
IS - 1
ER -