T1 - Clinical evaluation of an automatic blood-pressure monitoring device
AU - Modesti, P. A.
AU - Gensini, G. F.
AU - Conti, C.
AU - Neri Serneri, G. G.
PY - 1987
Y1 - 1987
N2 - Reliability and reproducibility of an automatic ambulatory blood pressure recorder (ICR-5200, Squibb) were tested on 45 subjects (24 normotensives and 21 hypertensives) aged 32-64 (mean age 49). Of 6,566 recordings, 2,376 measurements were cross-checked with a Riva Rocci sphygmomanometer in supine, standing, or sitting position at the beginning and at the end of a 24-hour monitoring period. Moreover, in 11 normotensives and in 11 hypertensives, cross-checking was performed during a cycloergometer effort test. A highly significant linear correlation was found in all the conditions tested (r = 0.98, p <0.001 for systolic and r = 0.98, p <0.001 for diastolic pressure) either in hypertensives or in normotensives. Only 8% of diastolic measurements performed by the two methods differed more than 5 mmHg. For each subject 5.4 ± 3.8% of the preprogrammed measurements were lost. Only seven out of 45 subjects referred a disturbed sleep. ICR-5200 seems a suitable and reliable tool for automatic blood-pressure recording.
AB - Reliability and reproducibility of an automatic ambulatory blood pressure recorder (ICR-5200, Squibb) were tested on 45 subjects (24 normotensives and 21 hypertensives) aged 32-64 (mean age 49). Of 6,566 recordings, 2,376 measurements were cross-checked with a Riva Rocci sphygmomanometer in supine, standing, or sitting position at the beginning and at the end of a 24-hour monitoring period. Moreover, in 11 normotensives and in 11 hypertensives, cross-checking was performed during a cycloergometer effort test. A highly significant linear correlation was found in all the conditions tested (r = 0.98, p <0.001 for systolic and r = 0.98, p <0.001 for diastolic pressure) either in hypertensives or in normotensives. Only 8% of diastolic measurements performed by the two methods differed more than 5 mmHg. For each subject 5.4 ± 3.8% of the preprogrammed measurements were lost. Only seven out of 45 subjects referred a disturbed sleep. ICR-5200 seems a suitable and reliable tool for automatic blood-pressure recording.
UR - http://www.scopus.com/inward/record.url?scp=0023609591&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0023609591&partnerID=8YFLogxK
M3 - Article
C2 - 3453394
AN - SCOPUS:0023609591
VL - 3
SP - 631
EP - 644
JO - Journal of the CardioMetabolic Syndrome
JF - Journal of the CardioMetabolic Syndrome
SN - 1524-6175
IS - 4
ER -