TY - JOUR
T1 - Comparison of stability and kinematics of the natural knee versus a PS TKA with a 'third condyle'
AU - Zaffagnini, Stefano
AU - Bignozzi, Simone
AU - Saffarini, Mo
AU - Colle, Francesca
AU - Sharma, Bharat
AU - Kinov, Plamen Slavov
AU - Marcacci, Maurilio
AU - Dejour, David
PY - 2014
Y1 - 2014
N2 - Purpose: The goal of this study was to compare the kinematics of knees before and after total knee arthroplasty (TKA) that relies on an inter-condylar 'third condyle'. The hypothesis was that the 'third condyle' provides sufficient flexion stability and induces a close to normal femoral rollback, thus granting natural joint kinematics. Methods: Intra-operative navigation data were collected from 29 consecutive cases that received a cemented TKA (HLS Noetos, Tornier SA, France) designed with an inter-condylar 'third condyle' that engages within the tibial insert beyond 35° flexion. Operations were guided by a non-image-based system (BLU-IGS, Orthokey Italia srl, Italy) that recorded relative femoral and tibial positions in native and implanted knees during: passive range of motion, anterior drawer test at 90° flexion, and varus-valgus stress tests at full extension and at 30° flexion. Results: The total internal tibial rotation during flexion was similar for native (8.2 ± 4.2°) and implanted knees (8.0 ± 5.4°). The lateral femoral condyle was more posterior in implanted knees (1.2 ± 9.4 mm) than in native knees (9.5 ± 3.6 mm) throughout early flexion (p <0.01), but this difference diminished beyond 100° flexion (n.s.). The implanted knees did not exhibit paradoxical external tibial rotation. Varus-valgus laxity in full extension was lower for implanted knees than for native knees (p = 0.0221), but at 30° flexion was almost identical for both native and implanted knees. Anteroposterior laxity was similar in implanted and native knees. Conclusions: The 'third condyle' TKA provides similar anteroposterior and mediolateral stability to the natural knee. This feature granted an adequate balance between laxity and constraint to reproduce natural joint kinematics, including smooth femoral rollback, without causing paradoxical external tibial rotation. Level of evidence: Comparative study, Level III.
AB - Purpose: The goal of this study was to compare the kinematics of knees before and after total knee arthroplasty (TKA) that relies on an inter-condylar 'third condyle'. The hypothesis was that the 'third condyle' provides sufficient flexion stability and induces a close to normal femoral rollback, thus granting natural joint kinematics. Methods: Intra-operative navigation data were collected from 29 consecutive cases that received a cemented TKA (HLS Noetos, Tornier SA, France) designed with an inter-condylar 'third condyle' that engages within the tibial insert beyond 35° flexion. Operations were guided by a non-image-based system (BLU-IGS, Orthokey Italia srl, Italy) that recorded relative femoral and tibial positions in native and implanted knees during: passive range of motion, anterior drawer test at 90° flexion, and varus-valgus stress tests at full extension and at 30° flexion. Results: The total internal tibial rotation during flexion was similar for native (8.2 ± 4.2°) and implanted knees (8.0 ± 5.4°). The lateral femoral condyle was more posterior in implanted knees (1.2 ± 9.4 mm) than in native knees (9.5 ± 3.6 mm) throughout early flexion (p <0.01), but this difference diminished beyond 100° flexion (n.s.). The implanted knees did not exhibit paradoxical external tibial rotation. Varus-valgus laxity in full extension was lower for implanted knees than for native knees (p = 0.0221), but at 30° flexion was almost identical for both native and implanted knees. Anteroposterior laxity was similar in implanted and native knees. Conclusions: The 'third condyle' TKA provides similar anteroposterior and mediolateral stability to the natural knee. This feature granted an adequate balance between laxity and constraint to reproduce natural joint kinematics, including smooth femoral rollback, without causing paradoxical external tibial rotation. Level of evidence: Comparative study, Level III.
KW - Kinematics
KW - Postero-stabilized knee
KW - Third condyle
KW - Total knee arthroplasty
UR - http://www.scopus.com/inward/record.url?scp=84904554960&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84904554960&partnerID=8YFLogxK
U2 - 10.1007/s00167-014-3016-3
DO - 10.1007/s00167-014-3016-3
M3 - Article
C2 - 24797810
AN - SCOPUS:84904554960
VL - 22
SP - 1778
EP - 1785
JO - Knee Surgery, Sports Traumatology, Arthroscopy
JF - Knee Surgery, Sports Traumatology, Arthroscopy
SN - 0942-2056
IS - 8
ER -