LA TOMOGRAFIA COMPUTERIZZATA E LA SCINTIGRAFIA NELLA VALUTAZIONE DEI PAZIENTI MIASTENICI

Translated title of the contribution: Computed tomography and scintigraphy in the evaluation of patients with myasthenia gravis

D. Fiore, P. R. Biondetti, R. Ravasini, A. Camposampiero, D. D'Amico, N. Bassi

Research output: Contribution to journalArticle

Abstract

14 patients with myasthenia gravis underwent routine plain chest radiograms, conventional anterior mediastinal tomography, thymus scintigraphy and computed tomography. The role of CT scan and scintigraphy in the evaluation of patients with suspected thymic abnormalities is analysed.

Original languageItalian
Pages (from-to)809-814
Number of pages6
JournalRadiologia Medica
Volume67
Issue number11
Publication statusPublished - 1981

Fingerprint

Myasthenia Gravis
Radionuclide Imaging
Tomography
Thymus Gland
Thorax

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Fiore, D., Biondetti, P. R., Ravasini, R., Camposampiero, A., D'Amico, D., & Bassi, N. (1981). LA TOMOGRAFIA COMPUTERIZZATA E LA SCINTIGRAFIA NELLA VALUTAZIONE DEI PAZIENTI MIASTENICI. Radiologia Medica, 67(11), 809-814.

LA TOMOGRAFIA COMPUTERIZZATA E LA SCINTIGRAFIA NELLA VALUTAZIONE DEI PAZIENTI MIASTENICI. / Fiore, D.; Biondetti, P. R.; Ravasini, R.; Camposampiero, A.; D'Amico, D.; Bassi, N.

In: Radiologia Medica, Vol. 67, No. 11, 1981, p. 809-814.

Research output: Contribution to journalArticle

Fiore, D, Biondetti, PR, Ravasini, R, Camposampiero, A, D'Amico, D & Bassi, N 1981, 'LA TOMOGRAFIA COMPUTERIZZATA E LA SCINTIGRAFIA NELLA VALUTAZIONE DEI PAZIENTI MIASTENICI', Radiologia Medica, vol. 67, no. 11, pp. 809-814.
Fiore D, Biondetti PR, Ravasini R, Camposampiero A, D'Amico D, Bassi N. LA TOMOGRAFIA COMPUTERIZZATA E LA SCINTIGRAFIA NELLA VALUTAZIONE DEI PAZIENTI MIASTENICI. Radiologia Medica. 1981;67(11):809-814.
Fiore, D. ; Biondetti, P. R. ; Ravasini, R. ; Camposampiero, A. ; D'Amico, D. ; Bassi, N. / LA TOMOGRAFIA COMPUTERIZZATA E LA SCINTIGRAFIA NELLA VALUTAZIONE DEI PAZIENTI MIASTENICI. In: Radiologia Medica. 1981 ; Vol. 67, No. 11. pp. 809-814.
@article{3982e1498bbc44ee87870bebf4f916da,
title = "LA TOMOGRAFIA COMPUTERIZZATA E LA SCINTIGRAFIA NELLA VALUTAZIONE DEI PAZIENTI MIASTENICI",
abstract = "14 patients with myasthenia gravis underwent routine plain chest radiograms, conventional anterior mediastinal tomography, thymus scintigraphy and computed tomography. The role of CT scan and scintigraphy in the evaluation of patients with suspected thymic abnormalities is analysed.",
author = "D. Fiore and Biondetti, {P. R.} and R. Ravasini and A. Camposampiero and D. D'Amico and N. Bassi",
year = "1981",
language = "Italian",
volume = "67",
pages = "809--814",
journal = "Radiologia Medica",
issn = "0033-8362",
publisher = "Springer-Verlag Italia s.r.l.",
number = "11",

}

TY - JOUR

T1 - LA TOMOGRAFIA COMPUTERIZZATA E LA SCINTIGRAFIA NELLA VALUTAZIONE DEI PAZIENTI MIASTENICI

AU - Fiore, D.

AU - Biondetti, P. R.

AU - Ravasini, R.

AU - Camposampiero, A.

AU - D'Amico, D.

AU - Bassi, N.

PY - 1981

Y1 - 1981

N2 - 14 patients with myasthenia gravis underwent routine plain chest radiograms, conventional anterior mediastinal tomography, thymus scintigraphy and computed tomography. The role of CT scan and scintigraphy in the evaluation of patients with suspected thymic abnormalities is analysed.

AB - 14 patients with myasthenia gravis underwent routine plain chest radiograms, conventional anterior mediastinal tomography, thymus scintigraphy and computed tomography. The role of CT scan and scintigraphy in the evaluation of patients with suspected thymic abnormalities is analysed.

UR - http://www.scopus.com/inward/record.url?scp=0019835217&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0019835217&partnerID=8YFLogxK

M3 - Articolo

C2 - 6977142

AN - SCOPUS:0019835217

VL - 67

SP - 809

EP - 814

JO - Radiologia Medica

JF - Radiologia Medica

SN - 0033-8362

IS - 11

ER -