Computer-aided flapless implant surgery and immediate loading. A technical note

Alfonso Baruffaldi, Pier Paolo Poli, Andrea Baruffaldi, Lorenzo Giberti, Maurizio Pigozzo, Carlo Maiorana

Research output: Contribution to journalArticle

Abstract

Purpose: The aim of the present technical note was to describe a prosthetic technique developed to increase the predictability of immediately loaded implants supporting a fixed prosthesis after computer-aided template-guided flapless implant placement. Methods: During a 2-year period, eight patients presenting partial edentulism underwent computer-aided template-guided implant placement. The presented technique was used during the prosthetic procedures to directly transfer the data obtained with the facebow to the surgical environment, allowing for accurate repositioning of the temporary prosthesis on the implants as previously planned with the digital software. Results: A total of 78 dental implants were immediately loaded with an implant-supported fixed prosthesis after flapless template-guided implant placement. A survival and success rate of 100 % was reported after a mean follow-up of 1 year from the prosthetic loading. Neither major complications nor dropouts were observed during the healing time. From both clinical and radiological evaluations, implants appeared stable with no signs of soft tissue inflammation or infection and no evidence of pathological peri-implant bone resorption. Conclusions: The proposed technique associated with computer-aided implant placement and immediate loading protocol provided a high implant and prosthetic survival and success rate. No complications were reported during the recalls, suggesting predictability and reliability of the present technique over a short-term period.

Original languageEnglish
Pages (from-to)1-7
Number of pages7
JournalOral and Maxillofacial Surgery
DOIs
Publication statusAccepted/In press - Apr 5 2016

Fingerprint

Prostheses and Implants
Survival Rate
Dental Implants
Bone Resorption
Software
Inflammation
Infection

Keywords

  • Computer-aided surgery
  • Dental implants
  • Fixed prosthesis
  • Immediate loading
  • Surgical template
  • Virtual planning

ASJC Scopus subject areas

  • Otorhinolaryngology
  • Surgery
  • Oral Surgery

Cite this

Computer-aided flapless implant surgery and immediate loading. A technical note. / Baruffaldi, Alfonso; Poli, Pier Paolo; Baruffaldi, Andrea; Giberti, Lorenzo; Pigozzo, Maurizio; Maiorana, Carlo.

In: Oral and Maxillofacial Surgery, 05.04.2016, p. 1-7.

Research output: Contribution to journalArticle

Baruffaldi, Alfonso ; Poli, Pier Paolo ; Baruffaldi, Andrea ; Giberti, Lorenzo ; Pigozzo, Maurizio ; Maiorana, Carlo. / Computer-aided flapless implant surgery and immediate loading. A technical note. In: Oral and Maxillofacial Surgery. 2016 ; pp. 1-7.
@article{7fa3688c27a94968879fb092c15d76dc,
title = "Computer-aided flapless implant surgery and immediate loading. A technical note",
abstract = "Purpose: The aim of the present technical note was to describe a prosthetic technique developed to increase the predictability of immediately loaded implants supporting a fixed prosthesis after computer-aided template-guided flapless implant placement. Methods: During a 2-year period, eight patients presenting partial edentulism underwent computer-aided template-guided implant placement. The presented technique was used during the prosthetic procedures to directly transfer the data obtained with the facebow to the surgical environment, allowing for accurate repositioning of the temporary prosthesis on the implants as previously planned with the digital software. Results: A total of 78 dental implants were immediately loaded with an implant-supported fixed prosthesis after flapless template-guided implant placement. A survival and success rate of 100 {\%} was reported after a mean follow-up of 1 year from the prosthetic loading. Neither major complications nor dropouts were observed during the healing time. From both clinical and radiological evaluations, implants appeared stable with no signs of soft tissue inflammation or infection and no evidence of pathological peri-implant bone resorption. Conclusions: The proposed technique associated with computer-aided implant placement and immediate loading protocol provided a high implant and prosthetic survival and success rate. No complications were reported during the recalls, suggesting predictability and reliability of the present technique over a short-term period.",
keywords = "Computer-aided surgery, Dental implants, Fixed prosthesis, Immediate loading, Surgical template, Virtual planning",
author = "Alfonso Baruffaldi and Poli, {Pier Paolo} and Andrea Baruffaldi and Lorenzo Giberti and Maurizio Pigozzo and Carlo Maiorana",
year = "2016",
month = "4",
day = "5",
doi = "10.1007/s10006-016-0554-5",
language = "English",
pages = "1--7",
journal = "Oral and Maxillofacial Surgery",
issn = "1865-1550",
publisher = "Springer Verlag",

}

TY - JOUR

T1 - Computer-aided flapless implant surgery and immediate loading. A technical note

AU - Baruffaldi, Alfonso

AU - Poli, Pier Paolo

AU - Baruffaldi, Andrea

AU - Giberti, Lorenzo

AU - Pigozzo, Maurizio

AU - Maiorana, Carlo

PY - 2016/4/5

Y1 - 2016/4/5

N2 - Purpose: The aim of the present technical note was to describe a prosthetic technique developed to increase the predictability of immediately loaded implants supporting a fixed prosthesis after computer-aided template-guided flapless implant placement. Methods: During a 2-year period, eight patients presenting partial edentulism underwent computer-aided template-guided implant placement. The presented technique was used during the prosthetic procedures to directly transfer the data obtained with the facebow to the surgical environment, allowing for accurate repositioning of the temporary prosthesis on the implants as previously planned with the digital software. Results: A total of 78 dental implants were immediately loaded with an implant-supported fixed prosthesis after flapless template-guided implant placement. A survival and success rate of 100 % was reported after a mean follow-up of 1 year from the prosthetic loading. Neither major complications nor dropouts were observed during the healing time. From both clinical and radiological evaluations, implants appeared stable with no signs of soft tissue inflammation or infection and no evidence of pathological peri-implant bone resorption. Conclusions: The proposed technique associated with computer-aided implant placement and immediate loading protocol provided a high implant and prosthetic survival and success rate. No complications were reported during the recalls, suggesting predictability and reliability of the present technique over a short-term period.

AB - Purpose: The aim of the present technical note was to describe a prosthetic technique developed to increase the predictability of immediately loaded implants supporting a fixed prosthesis after computer-aided template-guided flapless implant placement. Methods: During a 2-year period, eight patients presenting partial edentulism underwent computer-aided template-guided implant placement. The presented technique was used during the prosthetic procedures to directly transfer the data obtained with the facebow to the surgical environment, allowing for accurate repositioning of the temporary prosthesis on the implants as previously planned with the digital software. Results: A total of 78 dental implants were immediately loaded with an implant-supported fixed prosthesis after flapless template-guided implant placement. A survival and success rate of 100 % was reported after a mean follow-up of 1 year from the prosthetic loading. Neither major complications nor dropouts were observed during the healing time. From both clinical and radiological evaluations, implants appeared stable with no signs of soft tissue inflammation or infection and no evidence of pathological peri-implant bone resorption. Conclusions: The proposed technique associated with computer-aided implant placement and immediate loading protocol provided a high implant and prosthetic survival and success rate. No complications were reported during the recalls, suggesting predictability and reliability of the present technique over a short-term period.

KW - Computer-aided surgery

KW - Dental implants

KW - Fixed prosthesis

KW - Immediate loading

KW - Surgical template

KW - Virtual planning

UR - http://www.scopus.com/inward/record.url?scp=84962194596&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84962194596&partnerID=8YFLogxK

U2 - 10.1007/s10006-016-0554-5

DO - 10.1007/s10006-016-0554-5

M3 - Article

AN - SCOPUS:84962194596

SP - 1

EP - 7

JO - Oral and Maxillofacial Surgery

JF - Oral and Maxillofacial Surgery

SN - 1865-1550

ER -