Computer-assisted design of the sagittal shapes of a ligament-compatible total ankle replacement

A. Leardini, F. Catani, S. Giannini, J. J. O'Connor

Research output: Contribution to journalArticle

36 Citations (Scopus)

Abstract

The poor results of total ankle replacement have been attributed to the inability of designers to restore adequately the critical mutual function of the ligaments and the articular surfaces. The purpose of this study was to design sagittal shapes of the articular surfaces for a new ankle prosthesis to be compatible with the geometry of the retained ligamentous structures. Several ligament-compatible pairs of articular surfaces were tested using a computerised version of a four-bar linkage model. The kinematics of the ankle when replaced by non-conforming two-component and by fully conforming three-component designs with either flat, concave or convex tibial surfaces were assessed by the model. A ligament-compatible convex-tibia fully-congruent three-component prosthesis showed the best features. The three-component prosthesis allows complete congruence over the entire range of flexion. A convex shape for the tibial arc was preferred because of the better degree of entrapment of the meniscal bearing. A 5 cm convex-tibia arc radius gave 2 mm entrapment together with 9.8 mm of tibial bone cut. Ligament elongation imposed by full congruence of the articular surfaces was less than 0.03% of the original length. The original patterns of joint kinematics and ligament tensioning are closely restored in the joint replaced by the proposed prosthesis.

Original languageEnglish
Pages (from-to)168-175
Number of pages8
JournalMedical and Biological Engineering and Computing
Volume39
Issue number2
Publication statusPublished - 2001

Fingerprint

Ankle Replacement Arthroplasty
Computer-Aided Design
Ligaments
Joints
Prostheses and Implants
Tibia
Biomechanical Phenomena
Ankle
Articular Ligaments
Kinematics
Bearings (structural)
Elongation
Bone
Bone and Bones
Geometry

Keywords

  • Articular surfaces
  • Congruity
  • Geometrical modelling
  • Ligament
  • Meniscal bearing
  • Prosthesis design
  • Sagittal plane
  • Total ankle replacement

ASJC Scopus subject areas

  • Computational Theory and Mathematics
  • Computer Science Applications
  • Biomedical Engineering
  • Health Informatics
  • Health Information Management

Cite this

Computer-assisted design of the sagittal shapes of a ligament-compatible total ankle replacement. / Leardini, A.; Catani, F.; Giannini, S.; O'Connor, J. J.

In: Medical and Biological Engineering and Computing, Vol. 39, No. 2, 2001, p. 168-175.

Research output: Contribution to journalArticle

@article{67c70379be0b4ddd90c54ae15fb81658,
title = "Computer-assisted design of the sagittal shapes of a ligament-compatible total ankle replacement",
abstract = "The poor results of total ankle replacement have been attributed to the inability of designers to restore adequately the critical mutual function of the ligaments and the articular surfaces. The purpose of this study was to design sagittal shapes of the articular surfaces for a new ankle prosthesis to be compatible with the geometry of the retained ligamentous structures. Several ligament-compatible pairs of articular surfaces were tested using a computerised version of a four-bar linkage model. The kinematics of the ankle when replaced by non-conforming two-component and by fully conforming three-component designs with either flat, concave or convex tibial surfaces were assessed by the model. A ligament-compatible convex-tibia fully-congruent three-component prosthesis showed the best features. The three-component prosthesis allows complete congruence over the entire range of flexion. A convex shape for the tibial arc was preferred because of the better degree of entrapment of the meniscal bearing. A 5 cm convex-tibia arc radius gave 2 mm entrapment together with 9.8 mm of tibial bone cut. Ligament elongation imposed by full congruence of the articular surfaces was less than 0.03{\%} of the original length. The original patterns of joint kinematics and ligament tensioning are closely restored in the joint replaced by the proposed prosthesis.",
keywords = "Articular surfaces, Congruity, Geometrical modelling, Ligament, Meniscal bearing, Prosthesis design, Sagittal plane, Total ankle replacement",
author = "A. Leardini and F. Catani and S. Giannini and O'Connor, {J. J.}",
year = "2001",
language = "English",
volume = "39",
pages = "168--175",
journal = "Medical and Biological Engineering and Computing",
issn = "0140-0118",
publisher = "Springer Verlag",
number = "2",

}

TY - JOUR

T1 - Computer-assisted design of the sagittal shapes of a ligament-compatible total ankle replacement

AU - Leardini, A.

AU - Catani, F.

AU - Giannini, S.

AU - O'Connor, J. J.

PY - 2001

Y1 - 2001

N2 - The poor results of total ankle replacement have been attributed to the inability of designers to restore adequately the critical mutual function of the ligaments and the articular surfaces. The purpose of this study was to design sagittal shapes of the articular surfaces for a new ankle prosthesis to be compatible with the geometry of the retained ligamentous structures. Several ligament-compatible pairs of articular surfaces were tested using a computerised version of a four-bar linkage model. The kinematics of the ankle when replaced by non-conforming two-component and by fully conforming three-component designs with either flat, concave or convex tibial surfaces were assessed by the model. A ligament-compatible convex-tibia fully-congruent three-component prosthesis showed the best features. The three-component prosthesis allows complete congruence over the entire range of flexion. A convex shape for the tibial arc was preferred because of the better degree of entrapment of the meniscal bearing. A 5 cm convex-tibia arc radius gave 2 mm entrapment together with 9.8 mm of tibial bone cut. Ligament elongation imposed by full congruence of the articular surfaces was less than 0.03% of the original length. The original patterns of joint kinematics and ligament tensioning are closely restored in the joint replaced by the proposed prosthesis.

AB - The poor results of total ankle replacement have been attributed to the inability of designers to restore adequately the critical mutual function of the ligaments and the articular surfaces. The purpose of this study was to design sagittal shapes of the articular surfaces for a new ankle prosthesis to be compatible with the geometry of the retained ligamentous structures. Several ligament-compatible pairs of articular surfaces were tested using a computerised version of a four-bar linkage model. The kinematics of the ankle when replaced by non-conforming two-component and by fully conforming three-component designs with either flat, concave or convex tibial surfaces were assessed by the model. A ligament-compatible convex-tibia fully-congruent three-component prosthesis showed the best features. The three-component prosthesis allows complete congruence over the entire range of flexion. A convex shape for the tibial arc was preferred because of the better degree of entrapment of the meniscal bearing. A 5 cm convex-tibia arc radius gave 2 mm entrapment together with 9.8 mm of tibial bone cut. Ligament elongation imposed by full congruence of the articular surfaces was less than 0.03% of the original length. The original patterns of joint kinematics and ligament tensioning are closely restored in the joint replaced by the proposed prosthesis.

KW - Articular surfaces

KW - Congruity

KW - Geometrical modelling

KW - Ligament

KW - Meniscal bearing

KW - Prosthesis design

KW - Sagittal plane

KW - Total ankle replacement

UR - http://www.scopus.com/inward/record.url?scp=0035044090&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035044090&partnerID=8YFLogxK

M3 - Article

C2 - 11361242

AN - SCOPUS:0035044090

VL - 39

SP - 168

EP - 175

JO - Medical and Biological Engineering and Computing

JF - Medical and Biological Engineering and Computing

SN - 0140-0118

IS - 2

ER -