Creatine kinase-myocardial band isoenzyme elevation after percutaneous coronary interventions using sirolimus-eluting stents

Goran Stankovic, Alaide Chieffo, Ioannis Iakovou, Dejan Orlic, Nicola Corvaja, Giuseppe Sangiorgi, Flavio Airoldi, Antonio Colombo

Research output: Contribution to journalArticlepeer-review

Abstract

We evaluated predictors of increased periprocedural creatine kinase-MB isoenzyme levels after implantation of sirolimus-eluting stents with an intent to fully cover the diseased segment. The total stent length per patient (predisposing factor) and elective use of glycoprotein IIb/IIIa (protective factor) were independent predictors of increased creatine kinase-MB isoenzyme levels.

Original languageEnglish
Pages (from-to)1397-1401
Number of pages5
JournalThe American Journal of Cardiology
Volume93
Issue number11
DOIs
Publication statusPublished - Jun 1 2004

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Creatine kinase-myocardial band isoenzyme elevation after percutaneous coronary interventions using sirolimus-eluting stents'. Together they form a unique fingerprint.