CT images of abdomen and pelvis: Effect of nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics

S. M R Rizzo, Mannudeep K. Kalra, Bernhard Schmidt, Rainer Raupach, Michael M. Maher, Michael A. Blake, Sanjay Saini

Research output: Contribution to journalArticle

Abstract

The purpose of this study was to retrospectively assess the effect of a post-processing nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics in abdominal and pelvic computed tomographic (CT) images. Institutional review board approved the HIPAA-compliant study protocol; informed consent was waived. Abdominal and pelvic CT images (40 patients; male-female ratio, 20:20; age range, 28-86 years) at 5-mm (n = 20) and 2-mm (n = 20) section thicknesses were post-processed with the algorithm at three noise reduction levels. Image noise at the level of porta hepatis and acetabulum was evaluated with a five-point scale (1, no or minimal noise; 5, unacceptable noise), and presence and number of lesions and conspicuity were assessed. Statistical analysis was performed (Wilcoxon signed rank test, analysis of variance). Significant noise reduction was noted at all three levels with the algorithm (P <.05). Reduction in image contrast was noted with only one noise reduction level (P <.0001). The algorithm improves image noise without affecting lesion conspicuity and detection on low-dose abdominal and pelvic CT images.

Original languageEnglish
Pages (from-to)309-315
Number of pages7
JournalRadiology
Volume237
Issue number1
DOIs
Publication statusPublished - Oct 2005

Fingerprint

Pelvis
Abdomen
Noise
Health Insurance Portability and Accountability Act
Acetabulum
Research Ethics Committees
Nonparametric Statistics
Informed Consent
Analysis of Variance

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

CT images of abdomen and pelvis : Effect of nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics. / Rizzo, S. M R; Kalra, Mannudeep K.; Schmidt, Bernhard; Raupach, Rainer; Maher, Michael M.; Blake, Michael A.; Saini, Sanjay.

In: Radiology, Vol. 237, No. 1, 10.2005, p. 309-315.

Research output: Contribution to journalArticle

Rizzo, S. M R ; Kalra, Mannudeep K. ; Schmidt, Bernhard ; Raupach, Rainer ; Maher, Michael M. ; Blake, Michael A. ; Saini, Sanjay. / CT images of abdomen and pelvis : Effect of nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics. In: Radiology. 2005 ; Vol. 237, No. 1. pp. 309-315.
@article{bca08de12daa42fa8570d10639882923,
title = "CT images of abdomen and pelvis: Effect of nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics",
abstract = "The purpose of this study was to retrospectively assess the effect of a post-processing nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics in abdominal and pelvic computed tomographic (CT) images. Institutional review board approved the HIPAA-compliant study protocol; informed consent was waived. Abdominal and pelvic CT images (40 patients; male-female ratio, 20:20; age range, 28-86 years) at 5-mm (n = 20) and 2-mm (n = 20) section thicknesses were post-processed with the algorithm at three noise reduction levels. Image noise at the level of porta hepatis and acetabulum was evaluated with a five-point scale (1, no or minimal noise; 5, unacceptable noise), and presence and number of lesions and conspicuity were assessed. Statistical analysis was performed (Wilcoxon signed rank test, analysis of variance). Significant noise reduction was noted at all three levels with the algorithm (P <.05). Reduction in image contrast was noted with only one noise reduction level (P <.0001). The algorithm improves image noise without affecting lesion conspicuity and detection on low-dose abdominal and pelvic CT images.",
author = "Rizzo, {S. M R} and Kalra, {Mannudeep K.} and Bernhard Schmidt and Rainer Raupach and Maher, {Michael M.} and Blake, {Michael A.} and Sanjay Saini",
year = "2005",
month = "10",
doi = "10.1148/radiol.2371041879",
language = "English",
volume = "237",
pages = "309--315",
journal = "Radiology",
issn = "0033-8419",
publisher = "Radiological Society of North America Inc.",
number = "1",

}

TY - JOUR

T1 - CT images of abdomen and pelvis

T2 - Effect of nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics

AU - Rizzo, S. M R

AU - Kalra, Mannudeep K.

AU - Schmidt, Bernhard

AU - Raupach, Rainer

AU - Maher, Michael M.

AU - Blake, Michael A.

AU - Saini, Sanjay

PY - 2005/10

Y1 - 2005/10

N2 - The purpose of this study was to retrospectively assess the effect of a post-processing nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics in abdominal and pelvic computed tomographic (CT) images. Institutional review board approved the HIPAA-compliant study protocol; informed consent was waived. Abdominal and pelvic CT images (40 patients; male-female ratio, 20:20; age range, 28-86 years) at 5-mm (n = 20) and 2-mm (n = 20) section thicknesses were post-processed with the algorithm at three noise reduction levels. Image noise at the level of porta hepatis and acetabulum was evaluated with a five-point scale (1, no or minimal noise; 5, unacceptable noise), and presence and number of lesions and conspicuity were assessed. Statistical analysis was performed (Wilcoxon signed rank test, analysis of variance). Significant noise reduction was noted at all three levels with the algorithm (P <.05). Reduction in image contrast was noted with only one noise reduction level (P <.0001). The algorithm improves image noise without affecting lesion conspicuity and detection on low-dose abdominal and pelvic CT images.

AB - The purpose of this study was to retrospectively assess the effect of a post-processing nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics in abdominal and pelvic computed tomographic (CT) images. Institutional review board approved the HIPAA-compliant study protocol; informed consent was waived. Abdominal and pelvic CT images (40 patients; male-female ratio, 20:20; age range, 28-86 years) at 5-mm (n = 20) and 2-mm (n = 20) section thicknesses were post-processed with the algorithm at three noise reduction levels. Image noise at the level of porta hepatis and acetabulum was evaluated with a five-point scale (1, no or minimal noise; 5, unacceptable noise), and presence and number of lesions and conspicuity were assessed. Statistical analysis was performed (Wilcoxon signed rank test, analysis of variance). Significant noise reduction was noted at all three levels with the algorithm (P <.05). Reduction in image contrast was noted with only one noise reduction level (P <.0001). The algorithm improves image noise without affecting lesion conspicuity and detection on low-dose abdominal and pelvic CT images.

UR - http://www.scopus.com/inward/record.url?scp=25144432836&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=25144432836&partnerID=8YFLogxK

U2 - 10.1148/radiol.2371041879

DO - 10.1148/radiol.2371041879

M3 - Article

C2 - 16183939

AN - SCOPUS:25144432836

VL - 237

SP - 309

EP - 315

JO - Radiology

JF - Radiology

SN - 0033-8419

IS - 1

ER -