CT perfusion in oncology: How to do it

G. Petralia, L. Bonello, S. Viotti, L. Preda, G. D'Andrea, Massimo Bellomi

Research output: Contribution to journalArticle

56 Citations (Scopus)

Abstract

Robust technique and accurate data analysis are required for reliable computed tomography perfusion (CTp) imaging. Multislice CT is required for high temporal resolution scanning; 16-slice (or 64-slice) scanners are preferred for adequate volume coverage. After tumour localization, the volume of CTp imaging has to be positioned to include the maximum visible area of the tumour and an adequate arterial vessel. Dynamic scans at high temporal resolution (at least 1-s gantry rotation time) are performed to visualize the first pass of contrast agent within the tumour; repeated scans with low temporal resolution can be planned for late enhancement assessment. A short bolus of conventional iodinated contrast agent, preferably with high iodine concentration, is power injected at a high flow rate (>4 ml/s) in the antecubital vein. The breath-hold technique is required for CTp imaging of the chest and upper abdomen to avoid respiratory motion; free breathing is adequate for CTp imaging of the head, neck and pelvis. Using dedicated software, a region of interest (ROI) has to be placed in an adequate artery (as arterial input) to obtain density-time curves; according to different kinetic models, colour maps of different CTp parameters are generated and generally overlaid on CT images. Additional ROIs can be positioned in the tumour, and in all other parts of the CTp volume, to obtain the values of the CTp parameters within the ROI.

Original languageEnglish
Pages (from-to)8-19
Number of pages12
JournalCancer Imaging
Volume10
Issue number1
DOIs
Publication statusPublished - 2010

Fingerprint

Perfusion Imaging
Perfusion
Tomography
Cone-Beam Computed Tomography
Contrast Media
Neoplasms
Pelvis
Iodine
Abdomen
Veins
Respiration
Neck
Thorax
Software
Arteries
Color
Head

Keywords

  • Body tumours
  • CT perfusion
  • Kinetic models
  • Oncology
  • Prediction of response to therapy
  • Therapy monitoring

ASJC Scopus subject areas

  • Medicine(all)
  • Oncology
  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

CT perfusion in oncology : How to do it. / Petralia, G.; Bonello, L.; Viotti, S.; Preda, L.; D'Andrea, G.; Bellomi, Massimo.

In: Cancer Imaging, Vol. 10, No. 1, 2010, p. 8-19.

Research output: Contribution to journalArticle

Petralia, G. ; Bonello, L. ; Viotti, S. ; Preda, L. ; D'Andrea, G. ; Bellomi, Massimo. / CT perfusion in oncology : How to do it. In: Cancer Imaging. 2010 ; Vol. 10, No. 1. pp. 8-19.
@article{233e8fbc52ce473f896d93f5f7487c77,
title = "CT perfusion in oncology: How to do it",
abstract = "Robust technique and accurate data analysis are required for reliable computed tomography perfusion (CTp) imaging. Multislice CT is required for high temporal resolution scanning; 16-slice (or 64-slice) scanners are preferred for adequate volume coverage. After tumour localization, the volume of CTp imaging has to be positioned to include the maximum visible area of the tumour and an adequate arterial vessel. Dynamic scans at high temporal resolution (at least 1-s gantry rotation time) are performed to visualize the first pass of contrast agent within the tumour; repeated scans with low temporal resolution can be planned for late enhancement assessment. A short bolus of conventional iodinated contrast agent, preferably with high iodine concentration, is power injected at a high flow rate (>4 ml/s) in the antecubital vein. The breath-hold technique is required for CTp imaging of the chest and upper abdomen to avoid respiratory motion; free breathing is adequate for CTp imaging of the head, neck and pelvis. Using dedicated software, a region of interest (ROI) has to be placed in an adequate artery (as arterial input) to obtain density-time curves; according to different kinetic models, colour maps of different CTp parameters are generated and generally overlaid on CT images. Additional ROIs can be positioned in the tumour, and in all other parts of the CTp volume, to obtain the values of the CTp parameters within the ROI.",
keywords = "Body tumours, CT perfusion, Kinetic models, Oncology, Prediction of response to therapy, Therapy monitoring",
author = "G. Petralia and L. Bonello and S. Viotti and L. Preda and G. D'Andrea and Massimo Bellomi",
year = "2010",
doi = "10.1102/1470-7330.2010.0001",
language = "English",
volume = "10",
pages = "8--19",
journal = "Cancer Imaging",
issn = "1740-5025",
publisher = "e-med",
number = "1",

}

TY - JOUR

T1 - CT perfusion in oncology

T2 - How to do it

AU - Petralia, G.

AU - Bonello, L.

AU - Viotti, S.

AU - Preda, L.

AU - D'Andrea, G.

AU - Bellomi, Massimo

PY - 2010

Y1 - 2010

N2 - Robust technique and accurate data analysis are required for reliable computed tomography perfusion (CTp) imaging. Multislice CT is required for high temporal resolution scanning; 16-slice (or 64-slice) scanners are preferred for adequate volume coverage. After tumour localization, the volume of CTp imaging has to be positioned to include the maximum visible area of the tumour and an adequate arterial vessel. Dynamic scans at high temporal resolution (at least 1-s gantry rotation time) are performed to visualize the first pass of contrast agent within the tumour; repeated scans with low temporal resolution can be planned for late enhancement assessment. A short bolus of conventional iodinated contrast agent, preferably with high iodine concentration, is power injected at a high flow rate (>4 ml/s) in the antecubital vein. The breath-hold technique is required for CTp imaging of the chest and upper abdomen to avoid respiratory motion; free breathing is adequate for CTp imaging of the head, neck and pelvis. Using dedicated software, a region of interest (ROI) has to be placed in an adequate artery (as arterial input) to obtain density-time curves; according to different kinetic models, colour maps of different CTp parameters are generated and generally overlaid on CT images. Additional ROIs can be positioned in the tumour, and in all other parts of the CTp volume, to obtain the values of the CTp parameters within the ROI.

AB - Robust technique and accurate data analysis are required for reliable computed tomography perfusion (CTp) imaging. Multislice CT is required for high temporal resolution scanning; 16-slice (or 64-slice) scanners are preferred for adequate volume coverage. After tumour localization, the volume of CTp imaging has to be positioned to include the maximum visible area of the tumour and an adequate arterial vessel. Dynamic scans at high temporal resolution (at least 1-s gantry rotation time) are performed to visualize the first pass of contrast agent within the tumour; repeated scans with low temporal resolution can be planned for late enhancement assessment. A short bolus of conventional iodinated contrast agent, preferably with high iodine concentration, is power injected at a high flow rate (>4 ml/s) in the antecubital vein. The breath-hold technique is required for CTp imaging of the chest and upper abdomen to avoid respiratory motion; free breathing is adequate for CTp imaging of the head, neck and pelvis. Using dedicated software, a region of interest (ROI) has to be placed in an adequate artery (as arterial input) to obtain density-time curves; according to different kinetic models, colour maps of different CTp parameters are generated and generally overlaid on CT images. Additional ROIs can be positioned in the tumour, and in all other parts of the CTp volume, to obtain the values of the CTp parameters within the ROI.

KW - Body tumours

KW - CT perfusion

KW - Kinetic models

KW - Oncology

KW - Prediction of response to therapy

KW - Therapy monitoring

UR - http://www.scopus.com/inward/record.url?scp=77952311803&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77952311803&partnerID=8YFLogxK

U2 - 10.1102/1470-7330.2010.0001

DO - 10.1102/1470-7330.2010.0001

M3 - Article

C2 - 20159664

AN - SCOPUS:77952311803

VL - 10

SP - 8

EP - 19

JO - Cancer Imaging

JF - Cancer Imaging

SN - 1740-5025

IS - 1

ER -