Data and performances evaluation of the SPIDIA-DNA Pan-European External Quality Assessment

2nd SPIDIA-DNA laboratory report

Francesca Malentacchi, Sara Pizzamiglio, Hady Ibrahim-Gawel, Mario Pazzagli, Paolo Verderio, Chiara Maura Ciniselli, Ralf Wyrich, Stefania Gelmini

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Within the EU-SPIDIA project (www.spidia.eu), the quality parameters of blood genomic DNA were defined [SPIDIA-DNA: an External Quality Assessment for the pre-analytical phase of blood samples used for DNA-based analyses - [1]; Influence of pre-analytical procedures on genomic DNA integrity in blood samples: the SPIDIA experience - [2]; Combining qualitative and quantitative imaging evaluation for the assessment of genomic DNA integrity: the SPIDIA experience - [3]. DNA quality parameters were used to evaluate the laboratory performance within an External Quality Assessment (EQA) [Second SPIDIA-DNA External Quality Assessment (EQA): Influence of pre-analytical phase of blood samples on genomic DNA quality - [4]. These parameters included DNA purity and yield by UV spectrophotometric measurements, the presence of PCR interferences by Kineret software and genomic DNA integrity analysis by Pulsed Field Gel Electrophoresis.Here we present the specific laboratory report of the 2nd SPIDIA-DNA EQA as an example of data and performances evaluation.

Original languageEnglish
Pages (from-to)980-984
Number of pages5
JournalData in Brief
Volume6
DOIs
Publication statusPublished - Mar 1 2016

Fingerprint

evaluation
performance
integrity
interference
experience
EU

ASJC Scopus subject areas

  • General
  • Education

Cite this

Data and performances evaluation of the SPIDIA-DNA Pan-European External Quality Assessment : 2nd SPIDIA-DNA laboratory report. / Malentacchi, Francesca; Pizzamiglio, Sara; Ibrahim-Gawel, Hady; Pazzagli, Mario; Verderio, Paolo; Ciniselli, Chiara Maura; Wyrich, Ralf; Gelmini, Stefania.

In: Data in Brief, Vol. 6, 01.03.2016, p. 980-984.

Research output: Contribution to journalArticle

Malentacchi, F, Pizzamiglio, S, Ibrahim-Gawel, H, Pazzagli, M, Verderio, P, Ciniselli, CM, Wyrich, R & Gelmini, S 2016, 'Data and performances evaluation of the SPIDIA-DNA Pan-European External Quality Assessment: 2nd SPIDIA-DNA laboratory report', Data in Brief, vol. 6, pp. 980-984. https://doi.org/10.1016/j.dib.2016.01.062
Malentacchi, Francesca ; Pizzamiglio, Sara ; Ibrahim-Gawel, Hady ; Pazzagli, Mario ; Verderio, Paolo ; Ciniselli, Chiara Maura ; Wyrich, Ralf ; Gelmini, Stefania. / Data and performances evaluation of the SPIDIA-DNA Pan-European External Quality Assessment : 2nd SPIDIA-DNA laboratory report. In: Data in Brief. 2016 ; Vol. 6. pp. 980-984.
@article{ff46caad551149418676985a1056c09a,
title = "Data and performances evaluation of the SPIDIA-DNA Pan-European External Quality Assessment: 2nd SPIDIA-DNA laboratory report",
abstract = "Within the EU-SPIDIA project (www.spidia.eu), the quality parameters of blood genomic DNA were defined [SPIDIA-DNA: an External Quality Assessment for the pre-analytical phase of blood samples used for DNA-based analyses - [1]; Influence of pre-analytical procedures on genomic DNA integrity in blood samples: the SPIDIA experience - [2]; Combining qualitative and quantitative imaging evaluation for the assessment of genomic DNA integrity: the SPIDIA experience - [3]. DNA quality parameters were used to evaluate the laboratory performance within an External Quality Assessment (EQA) [Second SPIDIA-DNA External Quality Assessment (EQA): Influence of pre-analytical phase of blood samples on genomic DNA quality - [4]. These parameters included DNA purity and yield by UV spectrophotometric measurements, the presence of PCR interferences by Kineret software and genomic DNA integrity analysis by Pulsed Field Gel Electrophoresis.Here we present the specific laboratory report of the 2nd SPIDIA-DNA EQA as an example of data and performances evaluation.",
author = "Francesca Malentacchi and Sara Pizzamiglio and Hady Ibrahim-Gawel and Mario Pazzagli and Paolo Verderio and Ciniselli, {Chiara Maura} and Ralf Wyrich and Stefania Gelmini",
year = "2016",
month = "3",
day = "1",
doi = "10.1016/j.dib.2016.01.062",
language = "English",
volume = "6",
pages = "980--984",
journal = "Data in Brief",
issn = "2352-3409",
publisher = "Elsevier BV",

}

TY - JOUR

T1 - Data and performances evaluation of the SPIDIA-DNA Pan-European External Quality Assessment

T2 - 2nd SPIDIA-DNA laboratory report

AU - Malentacchi, Francesca

AU - Pizzamiglio, Sara

AU - Ibrahim-Gawel, Hady

AU - Pazzagli, Mario

AU - Verderio, Paolo

AU - Ciniselli, Chiara Maura

AU - Wyrich, Ralf

AU - Gelmini, Stefania

PY - 2016/3/1

Y1 - 2016/3/1

N2 - Within the EU-SPIDIA project (www.spidia.eu), the quality parameters of blood genomic DNA were defined [SPIDIA-DNA: an External Quality Assessment for the pre-analytical phase of blood samples used for DNA-based analyses - [1]; Influence of pre-analytical procedures on genomic DNA integrity in blood samples: the SPIDIA experience - [2]; Combining qualitative and quantitative imaging evaluation for the assessment of genomic DNA integrity: the SPIDIA experience - [3]. DNA quality parameters were used to evaluate the laboratory performance within an External Quality Assessment (EQA) [Second SPIDIA-DNA External Quality Assessment (EQA): Influence of pre-analytical phase of blood samples on genomic DNA quality - [4]. These parameters included DNA purity and yield by UV spectrophotometric measurements, the presence of PCR interferences by Kineret software and genomic DNA integrity analysis by Pulsed Field Gel Electrophoresis.Here we present the specific laboratory report of the 2nd SPIDIA-DNA EQA as an example of data and performances evaluation.

AB - Within the EU-SPIDIA project (www.spidia.eu), the quality parameters of blood genomic DNA were defined [SPIDIA-DNA: an External Quality Assessment for the pre-analytical phase of blood samples used for DNA-based analyses - [1]; Influence of pre-analytical procedures on genomic DNA integrity in blood samples: the SPIDIA experience - [2]; Combining qualitative and quantitative imaging evaluation for the assessment of genomic DNA integrity: the SPIDIA experience - [3]. DNA quality parameters were used to evaluate the laboratory performance within an External Quality Assessment (EQA) [Second SPIDIA-DNA External Quality Assessment (EQA): Influence of pre-analytical phase of blood samples on genomic DNA quality - [4]. These parameters included DNA purity and yield by UV spectrophotometric measurements, the presence of PCR interferences by Kineret software and genomic DNA integrity analysis by Pulsed Field Gel Electrophoresis.Here we present the specific laboratory report of the 2nd SPIDIA-DNA EQA as an example of data and performances evaluation.

UR - http://www.scopus.com/inward/record.url?scp=84958026055&partnerID=8YFLogxK