Determination of CS2 vapours by CP2 passive sampling device

L. Pozzoli, S. Ghittori, D. Cottica

Research output: Contribution to journalArticle

Abstract

Passive samplers to evaluate the solvent vapour concentration in the air are more and more frequent instead of traditional personal samplers. From our experience we decided to employ such samplers, also measuring CS2 vapours. The CP2 samplers that we have studied have been experimented with in a dynamic exposure chamber in which the CS2 concentrations could be calibrated; other experimental conditions can be summarized in such a way: use of different substrates to CS2, CS2 different speeds of exposition of the samplers, different calibrated CS2 concentrations. Data discussed here lead to a definition of the samplers in terms of collection substrate and exposition speed. Two analytical methods are proposed to measure CS2 absorbed: a traditional colorimetric and a gas-chomatographic by ECD. The use of the CP2 samplers in field is the consequence of satisfactory experimental results obtained in the laboratory.

Original languageEnglish
Pages (from-to)157-159
Number of pages3
JournalGiornale Italiano di Medicina del Lavoro
Volume3
Issue number2-3
Publication statusPublished - 1981

Fingerprint

Gases
Air
Equipment and Supplies

ASJC Scopus subject areas

  • Public Health, Environmental and Occupational Health
  • Rehabilitation

Cite this

Pozzoli, L., Ghittori, S., & Cottica, D. (1981). Determination of CS2 vapours by CP2 passive sampling device. Giornale Italiano di Medicina del Lavoro, 3(2-3), 157-159.

Determination of CS2 vapours by CP2 passive sampling device. / Pozzoli, L.; Ghittori, S.; Cottica, D.

In: Giornale Italiano di Medicina del Lavoro, Vol. 3, No. 2-3, 1981, p. 157-159.

Research output: Contribution to journalArticle

Pozzoli, L, Ghittori, S & Cottica, D 1981, 'Determination of CS2 vapours by CP2 passive sampling device', Giornale Italiano di Medicina del Lavoro, vol. 3, no. 2-3, pp. 157-159.
Pozzoli, L. ; Ghittori, S. ; Cottica, D. / Determination of CS2 vapours by CP2 passive sampling device. In: Giornale Italiano di Medicina del Lavoro. 1981 ; Vol. 3, No. 2-3. pp. 157-159.
@article{5840bb5e259c4f6a8a0c8d41458dd88c,
title = "Determination of CS2 vapours by CP2 passive sampling device",
abstract = "Passive samplers to evaluate the solvent vapour concentration in the air are more and more frequent instead of traditional personal samplers. From our experience we decided to employ such samplers, also measuring CS2 vapours. The CP2 samplers that we have studied have been experimented with in a dynamic exposure chamber in which the CS2 concentrations could be calibrated; other experimental conditions can be summarized in such a way: use of different substrates to CS2, CS2 different speeds of exposition of the samplers, different calibrated CS2 concentrations. Data discussed here lead to a definition of the samplers in terms of collection substrate and exposition speed. Two analytical methods are proposed to measure CS2 absorbed: a traditional colorimetric and a gas-chomatographic by ECD. The use of the CP2 samplers in field is the consequence of satisfactory experimental results obtained in the laboratory.",
author = "L. Pozzoli and S. Ghittori and D. Cottica",
year = "1981",
language = "English",
volume = "3",
pages = "157--159",
journal = "Giornale Italiano di Medicina del Lavoro",
issn = "0391-9889",
publisher = "Giardini Editori e Stampatori",
number = "2-3",

}

TY - JOUR

T1 - Determination of CS2 vapours by CP2 passive sampling device

AU - Pozzoli, L.

AU - Ghittori, S.

AU - Cottica, D.

PY - 1981

Y1 - 1981

N2 - Passive samplers to evaluate the solvent vapour concentration in the air are more and more frequent instead of traditional personal samplers. From our experience we decided to employ such samplers, also measuring CS2 vapours. The CP2 samplers that we have studied have been experimented with in a dynamic exposure chamber in which the CS2 concentrations could be calibrated; other experimental conditions can be summarized in such a way: use of different substrates to CS2, CS2 different speeds of exposition of the samplers, different calibrated CS2 concentrations. Data discussed here lead to a definition of the samplers in terms of collection substrate and exposition speed. Two analytical methods are proposed to measure CS2 absorbed: a traditional colorimetric and a gas-chomatographic by ECD. The use of the CP2 samplers in field is the consequence of satisfactory experimental results obtained in the laboratory.

AB - Passive samplers to evaluate the solvent vapour concentration in the air are more and more frequent instead of traditional personal samplers. From our experience we decided to employ such samplers, also measuring CS2 vapours. The CP2 samplers that we have studied have been experimented with in a dynamic exposure chamber in which the CS2 concentrations could be calibrated; other experimental conditions can be summarized in such a way: use of different substrates to CS2, CS2 different speeds of exposition of the samplers, different calibrated CS2 concentrations. Data discussed here lead to a definition of the samplers in terms of collection substrate and exposition speed. Two analytical methods are proposed to measure CS2 absorbed: a traditional colorimetric and a gas-chomatographic by ECD. The use of the CP2 samplers in field is the consequence of satisfactory experimental results obtained in the laboratory.

UR - http://www.scopus.com/inward/record.url?scp=0019794456&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0019794456&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0019794456

VL - 3

SP - 157

EP - 159

JO - Giornale Italiano di Medicina del Lavoro

JF - Giornale Italiano di Medicina del Lavoro

SN - 0391-9889

IS - 2-3

ER -