TY - JOUR
T1 - Does ion release differ between hip resurfacing and metal-on-metal THA?
AU - Moroni, Antonio
AU - Savarino, Lucia
AU - Cadossi, Matteo
AU - Baldini, Nicola
AU - Giannini, Sandro
PY - 2008/3
Y1 - 2008/3
N2 - Modern metal-on-metal hip resurfacing was introduced as a bone-preserving method of joint reconstruction for young and active patients; however, the large diameter of the bearing surfaces is of concern for potential increased metal ion release. We hypothesized there were no differences in serum concentrations of chromium, cobalt, and molybdenum between patients who had metal-on-metal hip resurfacing (Group A; average head diameter, 48 mm; median followup, 24 months) and patients who had 28-mm metal-on-metal THA (Group B; median followup, 25 months). Serum concentrations also were compared with concentrations in healthy subjects. We identified no differences in ion levels between Groups A and B. A distinction was made according to gender. Women showed a higher chromium release in Group A whereas men had a higher cobalt release in Group B. Values obtained from Group A were higher than those of the control subjects. Our data suggest metal-on-metal bearings for THA should not be rejected because of concern regarding potential increased metal ion release; however, patients with elevated ion levels, even without loosening or toxicity, could be at higher risk and should be followed up periodically. Level of Evidence: Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
AB - Modern metal-on-metal hip resurfacing was introduced as a bone-preserving method of joint reconstruction for young and active patients; however, the large diameter of the bearing surfaces is of concern for potential increased metal ion release. We hypothesized there were no differences in serum concentrations of chromium, cobalt, and molybdenum between patients who had metal-on-metal hip resurfacing (Group A; average head diameter, 48 mm; median followup, 24 months) and patients who had 28-mm metal-on-metal THA (Group B; median followup, 25 months). Serum concentrations also were compared with concentrations in healthy subjects. We identified no differences in ion levels between Groups A and B. A distinction was made according to gender. Women showed a higher chromium release in Group A whereas men had a higher cobalt release in Group B. Values obtained from Group A were higher than those of the control subjects. Our data suggest metal-on-metal bearings for THA should not be rejected because of concern regarding potential increased metal ion release; however, patients with elevated ion levels, even without loosening or toxicity, could be at higher risk and should be followed up periodically. Level of Evidence: Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
UR - http://www.scopus.com/inward/record.url?scp=42449094638&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=42449094638&partnerID=8YFLogxK
U2 - 10.1007/s11999-007-0106-2
DO - 10.1007/s11999-007-0106-2
M3 - Article
C2 - 18196364
AN - SCOPUS:42449094638
VL - 466
SP - 700
EP - 707
JO - Clinical Orthopaedics and Related Research
JF - Clinical Orthopaedics and Related Research
SN - 0009-921X
IS - 3
ER -