L'eco-Doppler nella valutazione intraoperatoria del circolo epatico: studio sperimentale nel suino.

Translated title of the contribution: Doppler echography in the intraoperative assessment of the liver circulation: an experimental study in swine

S. Gruttadauria, S. Prestia, G. Marino, A. Gentile, A. V. Sgroi, C. Cavallaro, S. Libra, G. Gruttadauria

Research output: Contribution to journalArticle

Abstract

In this experimental study the authors report an experience in the evaluation of hepatic blood flow with intraoperative echo-Doppler during orthotopic liver transplantation and side-to-side or end-to-side portacaval shunt. Doppler ultrasonography studied the flow of portal vein, hepatic artery and inferior vena cava before the recipient hepatectomy, and after reperfusion during liver grafting. Furthermore echo-Doppler of the portal system was performed to confirm portacaval shunt efficacy. Usually intraoperative Doppler ultrasonography may give informations about the patency of the shunt and regarding the development of early hepatic artery thrombosis during liver transplantation, but often unclear is the exact evaluation of the velocity of the blood flow through the liver. Further experimental studies and clinical evaluations need to find safe parameters and markers of vascular alteration using this superior diagnostic procedure.

Original languageItalian
Pages (from-to)191-194
Number of pages4
JournalGiornale di Chirurgia
Volume20
Issue number4
Publication statusPublished - Apr 1999

Fingerprint

Liver Circulation
Liver Transplantation
Surgical Portacaval Shunt
Doppler Ultrasonography
Ultrasonography
Swine
Hepatic Artery
Portal System
Blood Flow Velocity
Liver
Inferior Vena Cava
Hepatectomy
Portal Vein
Reperfusion
Blood Vessels
Thrombosis

ASJC Scopus subject areas

  • Surgery

Cite this

Gruttadauria, S., Prestia, S., Marino, G., Gentile, A., Sgroi, A. V., Cavallaro, C., ... Gruttadauria, G. (1999). L'eco-Doppler nella valutazione intraoperatoria del circolo epatico: studio sperimentale nel suino. Giornale di Chirurgia, 20(4), 191-194.

L'eco-Doppler nella valutazione intraoperatoria del circolo epatico : studio sperimentale nel suino. / Gruttadauria, S.; Prestia, S.; Marino, G.; Gentile, A.; Sgroi, A. V.; Cavallaro, C.; Libra, S.; Gruttadauria, G.

In: Giornale di Chirurgia, Vol. 20, No. 4, 04.1999, p. 191-194.

Research output: Contribution to journalArticle

Gruttadauria, S, Prestia, S, Marino, G, Gentile, A, Sgroi, AV, Cavallaro, C, Libra, S & Gruttadauria, G 1999, 'L'eco-Doppler nella valutazione intraoperatoria del circolo epatico: studio sperimentale nel suino.', Giornale di Chirurgia, vol. 20, no. 4, pp. 191-194.
Gruttadauria, S. ; Prestia, S. ; Marino, G. ; Gentile, A. ; Sgroi, A. V. ; Cavallaro, C. ; Libra, S. ; Gruttadauria, G. / L'eco-Doppler nella valutazione intraoperatoria del circolo epatico : studio sperimentale nel suino. In: Giornale di Chirurgia. 1999 ; Vol. 20, No. 4. pp. 191-194.
@article{030278f9fefe4e8b8ca10d29641b10a1,
title = "L'eco-Doppler nella valutazione intraoperatoria del circolo epatico: studio sperimentale nel suino.",
abstract = "In this experimental study the authors report an experience in the evaluation of hepatic blood flow with intraoperative echo-Doppler during orthotopic liver transplantation and side-to-side or end-to-side portacaval shunt. Doppler ultrasonography studied the flow of portal vein, hepatic artery and inferior vena cava before the recipient hepatectomy, and after reperfusion during liver grafting. Furthermore echo-Doppler of the portal system was performed to confirm portacaval shunt efficacy. Usually intraoperative Doppler ultrasonography may give informations about the patency of the shunt and regarding the development of early hepatic artery thrombosis during liver transplantation, but often unclear is the exact evaluation of the velocity of the blood flow through the liver. Further experimental studies and clinical evaluations need to find safe parameters and markers of vascular alteration using this superior diagnostic procedure.",
author = "S. Gruttadauria and S. Prestia and G. Marino and A. Gentile and Sgroi, {A. V.} and C. Cavallaro and S. Libra and G. Gruttadauria",
year = "1999",
month = "4",
language = "Italian",
volume = "20",
pages = "191--194",
journal = "Giornale di Chirurgia",
issn = "0391-9005",
publisher = "CIC Edizioni Internazionali s.r.l.",
number = "4",

}

TY - JOUR

T1 - L'eco-Doppler nella valutazione intraoperatoria del circolo epatico

T2 - studio sperimentale nel suino.

AU - Gruttadauria, S.

AU - Prestia, S.

AU - Marino, G.

AU - Gentile, A.

AU - Sgroi, A. V.

AU - Cavallaro, C.

AU - Libra, S.

AU - Gruttadauria, G.

PY - 1999/4

Y1 - 1999/4

N2 - In this experimental study the authors report an experience in the evaluation of hepatic blood flow with intraoperative echo-Doppler during orthotopic liver transplantation and side-to-side or end-to-side portacaval shunt. Doppler ultrasonography studied the flow of portal vein, hepatic artery and inferior vena cava before the recipient hepatectomy, and after reperfusion during liver grafting. Furthermore echo-Doppler of the portal system was performed to confirm portacaval shunt efficacy. Usually intraoperative Doppler ultrasonography may give informations about the patency of the shunt and regarding the development of early hepatic artery thrombosis during liver transplantation, but often unclear is the exact evaluation of the velocity of the blood flow through the liver. Further experimental studies and clinical evaluations need to find safe parameters and markers of vascular alteration using this superior diagnostic procedure.

AB - In this experimental study the authors report an experience in the evaluation of hepatic blood flow with intraoperative echo-Doppler during orthotopic liver transplantation and side-to-side or end-to-side portacaval shunt. Doppler ultrasonography studied the flow of portal vein, hepatic artery and inferior vena cava before the recipient hepatectomy, and after reperfusion during liver grafting. Furthermore echo-Doppler of the portal system was performed to confirm portacaval shunt efficacy. Usually intraoperative Doppler ultrasonography may give informations about the patency of the shunt and regarding the development of early hepatic artery thrombosis during liver transplantation, but often unclear is the exact evaluation of the velocity of the blood flow through the liver. Further experimental studies and clinical evaluations need to find safe parameters and markers of vascular alteration using this superior diagnostic procedure.

UR - http://www.scopus.com/inward/record.url?scp=0033111741&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033111741&partnerID=8YFLogxK

M3 - Articolo

C2 - 10230126

AN - SCOPUS:0033111741

VL - 20

SP - 191

EP - 194

JO - Giornale di Chirurgia

JF - Giornale di Chirurgia

SN - 0391-9005

IS - 4

ER -