T1 - Dosimetric accuracy assessment of a treatment plan verification system for scanned proton beam radiotherapy
T2 - One-year experimental results and Monte Carlo analysis of the involved uncertainties
AU - Molinelli, S.
AU - Mairani, A.
AU - Mirandola, A.
AU - Vilches Freixas, G.
AU - Tessonnier, T.
AU - Giordanengo, S.
AU - Parodi, K.
AU - Ciocca, M.
AU - Orecchia, R.
PY - 2013/6/7
Y1 - 2013/6/7
N2 - During one year of clinical activity at the Italian National Center for Oncological Hadron Therapy 31 patients were treated with actively scanned proton beams. Results of patient-specific quality assurance procedures are presented here which assess the accuracy of a three-dimensional dose verification technique with the simultaneous use of multiple small-volume ionization chambers. To investigate critical cases of major deviations between treatment planning system (TPS) calculated and measured data points, a Monte Carlo (MC) simulation tool was implemented for plan verification in water. Starting from MC results, the impact of dose calculation, dose delivery and measurement set-up uncertainties on plan verification results was analyzed. All resulting patient-specific quality checks were within the acceptance threshold, which was set at 5% for both mean deviation between measured and calculated doses and standard deviation. The mean deviation between TPS dose calculation and measurement was less than ±3% in 86% of the cases. When all three sources of uncertainty were accounted for, simulated data sets showed a high level of agreement, with mean and maximum absolute deviation lower than 2.5% and 5%, respectively.
AB - During one year of clinical activity at the Italian National Center for Oncological Hadron Therapy 31 patients were treated with actively scanned proton beams. Results of patient-specific quality assurance procedures are presented here which assess the accuracy of a three-dimensional dose verification technique with the simultaneous use of multiple small-volume ionization chambers. To investigate critical cases of major deviations between treatment planning system (TPS) calculated and measured data points, a Monte Carlo (MC) simulation tool was implemented for plan verification in water. Starting from MC results, the impact of dose calculation, dose delivery and measurement set-up uncertainties on plan verification results was analyzed. All resulting patient-specific quality checks were within the acceptance threshold, which was set at 5% for both mean deviation between measured and calculated doses and standard deviation. The mean deviation between TPS dose calculation and measurement was less than ±3% in 86% of the cases. When all three sources of uncertainty were accounted for, simulated data sets showed a high level of agreement, with mean and maximum absolute deviation lower than 2.5% and 5%, respectively.
UR - http://www.scopus.com/inward/record.url?scp=84878219970&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84878219970&partnerID=8YFLogxK
U2 - 10.1088/0031-9155/58/11/3837
DO - 10.1088/0031-9155/58/11/3837
M3 - Article
C2 - 23681116
AN - SCOPUS:84878219970
VL - 58
SP - 3837
EP - 3847
JO - Physics in Medicine and Biology
JF - Physics in Medicine and Biology
SN - 0031-9155
IS - 11
ER -