DOSIMETRIA DELLA VESCICA E DEL RETTO: CONFRONTO FRA LE DOSI MISURATE E LE DOSI CALCOLATE

Translated title of the contribution: Dosimetry of the bladder and the rectum: Comparison between the measured and calculated dose

G. Pizzi, S. Maluta, C. Polico, F. Calzavara, L. Loreggian, R. Fabbris, C. Cauzzo, O. Nibale, P. Francescon

Research output: Contribution to journalArticle

Abstract

The authors examine 62 cases of curietherapy in the deep vagina and 21 cases of utero-vaginal applications, and make a comparison between two dosimetric methods used to measure the dose to the rectum and to the bladder: the direct measure by the Siemens Gammameter disometer and the Chassagne-Horiot method. Very large differences were found between the doses evaluated by two methods. The values with the direct measure were often found to be higher than the calculated ones. When the measurements were done by different doctors, the result was almost the same.

Original languageItalian
Pages (from-to)743-747
Number of pages5
JournalRadiologia Medica
Volume67
Issue number10
Publication statusPublished - 1981

Fingerprint

Rectum
Urinary Bladder
Brachytherapy
Vagina

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Pizzi, G., Maluta, S., Polico, C., Calzavara, F., Loreggian, L., Fabbris, R., ... Francescon, P. (1981). DOSIMETRIA DELLA VESCICA E DEL RETTO: CONFRONTO FRA LE DOSI MISURATE E LE DOSI CALCOLATE. Radiologia Medica, 67(10), 743-747.

DOSIMETRIA DELLA VESCICA E DEL RETTO : CONFRONTO FRA LE DOSI MISURATE E LE DOSI CALCOLATE. / Pizzi, G.; Maluta, S.; Polico, C.; Calzavara, F.; Loreggian, L.; Fabbris, R.; Cauzzo, C.; Nibale, O.; Francescon, P.

In: Radiologia Medica, Vol. 67, No. 10, 1981, p. 743-747.

Research output: Contribution to journalArticle

Pizzi, G, Maluta, S, Polico, C, Calzavara, F, Loreggian, L, Fabbris, R, Cauzzo, C, Nibale, O & Francescon, P 1981, 'DOSIMETRIA DELLA VESCICA E DEL RETTO: CONFRONTO FRA LE DOSI MISURATE E LE DOSI CALCOLATE', Radiologia Medica, vol. 67, no. 10, pp. 743-747.
Pizzi G, Maluta S, Polico C, Calzavara F, Loreggian L, Fabbris R et al. DOSIMETRIA DELLA VESCICA E DEL RETTO: CONFRONTO FRA LE DOSI MISURATE E LE DOSI CALCOLATE. Radiologia Medica. 1981;67(10):743-747.
Pizzi, G. ; Maluta, S. ; Polico, C. ; Calzavara, F. ; Loreggian, L. ; Fabbris, R. ; Cauzzo, C. ; Nibale, O. ; Francescon, P. / DOSIMETRIA DELLA VESCICA E DEL RETTO : CONFRONTO FRA LE DOSI MISURATE E LE DOSI CALCOLATE. In: Radiologia Medica. 1981 ; Vol. 67, No. 10. pp. 743-747.
@article{d35050fadd4d43e79c2890fc76213156,
title = "DOSIMETRIA DELLA VESCICA E DEL RETTO: CONFRONTO FRA LE DOSI MISURATE E LE DOSI CALCOLATE",
abstract = "The authors examine 62 cases of curietherapy in the deep vagina and 21 cases of utero-vaginal applications, and make a comparison between two dosimetric methods used to measure the dose to the rectum and to the bladder: the direct measure by the Siemens Gammameter disometer and the Chassagne-Horiot method. Very large differences were found between the doses evaluated by two methods. The values with the direct measure were often found to be higher than the calculated ones. When the measurements were done by different doctors, the result was almost the same.",
author = "G. Pizzi and S. Maluta and C. Polico and F. Calzavara and L. Loreggian and R. Fabbris and C. Cauzzo and O. Nibale and P. Francescon",
year = "1981",
language = "Italian",
volume = "67",
pages = "743--747",
journal = "Radiologia Medica",
issn = "0033-8362",
publisher = "Springer-Verlag Italia s.r.l.",
number = "10",

}

TY - JOUR

T1 - DOSIMETRIA DELLA VESCICA E DEL RETTO

T2 - CONFRONTO FRA LE DOSI MISURATE E LE DOSI CALCOLATE

AU - Pizzi, G.

AU - Maluta, S.

AU - Polico, C.

AU - Calzavara, F.

AU - Loreggian, L.

AU - Fabbris, R.

AU - Cauzzo, C.

AU - Nibale, O.

AU - Francescon, P.

PY - 1981

Y1 - 1981

N2 - The authors examine 62 cases of curietherapy in the deep vagina and 21 cases of utero-vaginal applications, and make a comparison between two dosimetric methods used to measure the dose to the rectum and to the bladder: the direct measure by the Siemens Gammameter disometer and the Chassagne-Horiot method. Very large differences were found between the doses evaluated by two methods. The values with the direct measure were often found to be higher than the calculated ones. When the measurements were done by different doctors, the result was almost the same.

AB - The authors examine 62 cases of curietherapy in the deep vagina and 21 cases of utero-vaginal applications, and make a comparison between two dosimetric methods used to measure the dose to the rectum and to the bladder: the direct measure by the Siemens Gammameter disometer and the Chassagne-Horiot method. Very large differences were found between the doses evaluated by two methods. The values with the direct measure were often found to be higher than the calculated ones. When the measurements were done by different doctors, the result was almost the same.

UR - http://www.scopus.com/inward/record.url?scp=0019843390&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0019843390&partnerID=8YFLogxK

M3 - Articolo

C2 - 7323338

AN - SCOPUS:0019843390

VL - 67

SP - 743

EP - 747

JO - Radiologia Medica

JF - Radiologia Medica

SN - 0033-8362

IS - 10

ER -