Effect of astigmatism on multifocal intraocular lenses

Giuseppe Ravalico, Fulvio Parentin, Fabio Baccara

Research output: Contribution to journalArticle

33 Citations (Scopus)

Abstract

Purpose: To study the effect of astigmatism on multifocal intraocular lens (MIOL) function. Setting: Laser Laboratory, Department of Electronics, Electrotechnics and Informatics, University of Trieste, Italy. Methods: Using an experimental optical system, this study compared the division of a laser beam in the focal spots of 1 monofocal IOL (Pharmacia 722A), 1 bifocal IOL (Pharmacia 811E), and 2 MIOLs (AMO Array MPC25NB and Domilens Progress 1). The model consists of a helium-neon laser and an optical system: a triangular optical bench with a precision collimator, a micropositionable immersion stage to support the IOL, and a digital image-processing system. A stigmatism was induced by interposing a + 1.0 diopter (D) cylinder lens between the IOL and the television camera. Astigmatism was corrected by adding a -1.0 D cylinder lens in front of the Results: Astigmatism creates pairs of focal lines, 1 for each focal spot in the IOL. In the multifocal IOL, the posterior focal line of the nearest focus interfered with the anterior line of the next focus. Correcting the astigmatism led to a significant reduction (mean 20%) in light intensity. Conclusions: Astigmatically neutral surgery or surgical correction of pre-existing astigmatism is essential in MIOL implantation to minimize sensitivity.

Original languageEnglish
Pages (from-to)804-807
Number of pages4
JournalJournal of Cataract and Refractive Surgery
Volume25
Issue number6
DOIs
Publication statusPublished - 1999

Fingerprint

Astigmatism
Intraocular Lenses
Optical Devices
Lenses
Lasers
Neon
Informatics
Intraocular Lens Implantation
Gas Lasers
Television
Immersion
Italy
Light

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Effect of astigmatism on multifocal intraocular lenses. / Ravalico, Giuseppe; Parentin, Fulvio; Baccara, Fabio.

In: Journal of Cataract and Refractive Surgery, Vol. 25, No. 6, 1999, p. 804-807.

Research output: Contribution to journalArticle

Ravalico, Giuseppe ; Parentin, Fulvio ; Baccara, Fabio. / Effect of astigmatism on multifocal intraocular lenses. In: Journal of Cataract and Refractive Surgery. 1999 ; Vol. 25, No. 6. pp. 804-807.
@article{b974c82b2dd445678d14628fdc9c6b5e,
title = "Effect of astigmatism on multifocal intraocular lenses",
abstract = "Purpose: To study the effect of astigmatism on multifocal intraocular lens (MIOL) function. Setting: Laser Laboratory, Department of Electronics, Electrotechnics and Informatics, University of Trieste, Italy. Methods: Using an experimental optical system, this study compared the division of a laser beam in the focal spots of 1 monofocal IOL (Pharmacia 722A), 1 bifocal IOL (Pharmacia 811E), and 2 MIOLs (AMO Array MPC25NB and Domilens Progress 1). The model consists of a helium-neon laser and an optical system: a triangular optical bench with a precision collimator, a micropositionable immersion stage to support the IOL, and a digital image-processing system. A stigmatism was induced by interposing a + 1.0 diopter (D) cylinder lens between the IOL and the television camera. Astigmatism was corrected by adding a -1.0 D cylinder lens in front of the Results: Astigmatism creates pairs of focal lines, 1 for each focal spot in the IOL. In the multifocal IOL, the posterior focal line of the nearest focus interfered with the anterior line of the next focus. Correcting the astigmatism led to a significant reduction (mean 20{\%}) in light intensity. Conclusions: Astigmatically neutral surgery or surgical correction of pre-existing astigmatism is essential in MIOL implantation to minimize sensitivity.",
author = "Giuseppe Ravalico and Fulvio Parentin and Fabio Baccara",
year = "1999",
doi = "10.1016/S0886-3350(99)00029-2",
language = "English",
volume = "25",
pages = "804--807",
journal = "Journal of Cataract and Refractive Surgery",
issn = "0886-3350",
publisher = "Elsevier Inc.",
number = "6",

}

TY - JOUR

T1 - Effect of astigmatism on multifocal intraocular lenses

AU - Ravalico, Giuseppe

AU - Parentin, Fulvio

AU - Baccara, Fabio

PY - 1999

Y1 - 1999

N2 - Purpose: To study the effect of astigmatism on multifocal intraocular lens (MIOL) function. Setting: Laser Laboratory, Department of Electronics, Electrotechnics and Informatics, University of Trieste, Italy. Methods: Using an experimental optical system, this study compared the division of a laser beam in the focal spots of 1 monofocal IOL (Pharmacia 722A), 1 bifocal IOL (Pharmacia 811E), and 2 MIOLs (AMO Array MPC25NB and Domilens Progress 1). The model consists of a helium-neon laser and an optical system: a triangular optical bench with a precision collimator, a micropositionable immersion stage to support the IOL, and a digital image-processing system. A stigmatism was induced by interposing a + 1.0 diopter (D) cylinder lens between the IOL and the television camera. Astigmatism was corrected by adding a -1.0 D cylinder lens in front of the Results: Astigmatism creates pairs of focal lines, 1 for each focal spot in the IOL. In the multifocal IOL, the posterior focal line of the nearest focus interfered with the anterior line of the next focus. Correcting the astigmatism led to a significant reduction (mean 20%) in light intensity. Conclusions: Astigmatically neutral surgery or surgical correction of pre-existing astigmatism is essential in MIOL implantation to minimize sensitivity.

AB - Purpose: To study the effect of astigmatism on multifocal intraocular lens (MIOL) function. Setting: Laser Laboratory, Department of Electronics, Electrotechnics and Informatics, University of Trieste, Italy. Methods: Using an experimental optical system, this study compared the division of a laser beam in the focal spots of 1 monofocal IOL (Pharmacia 722A), 1 bifocal IOL (Pharmacia 811E), and 2 MIOLs (AMO Array MPC25NB and Domilens Progress 1). The model consists of a helium-neon laser and an optical system: a triangular optical bench with a precision collimator, a micropositionable immersion stage to support the IOL, and a digital image-processing system. A stigmatism was induced by interposing a + 1.0 diopter (D) cylinder lens between the IOL and the television camera. Astigmatism was corrected by adding a -1.0 D cylinder lens in front of the Results: Astigmatism creates pairs of focal lines, 1 for each focal spot in the IOL. In the multifocal IOL, the posterior focal line of the nearest focus interfered with the anterior line of the next focus. Correcting the astigmatism led to a significant reduction (mean 20%) in light intensity. Conclusions: Astigmatically neutral surgery or surgical correction of pre-existing astigmatism is essential in MIOL implantation to minimize sensitivity.

UR - http://www.scopus.com/inward/record.url?scp=0033024621&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033024621&partnerID=8YFLogxK

U2 - 10.1016/S0886-3350(99)00029-2

DO - 10.1016/S0886-3350(99)00029-2

M3 - Article

C2 - 10374161

AN - SCOPUS:0033024621

VL - 25

SP - 804

EP - 807

JO - Journal of Cataract and Refractive Surgery

JF - Journal of Cataract and Refractive Surgery

SN - 0886-3350

IS - 6

ER -