Effect of the initial implant fitting on the predicted secondary stability of a cementless stem

Marco Viceconti, A. Pancanti, M. Dotti, F. Traina, L. Cristofolini

Research output: Contribution to journalArticle

21 Citations (Scopus)

Abstract

A numerical model able to investigate the influence of biomechanical factors of the long-term secondary stability of implants would be extremely useful for the design of new cementless prosthetic devices. A purely biomechanical model of osseo-integration has been developed, formulated as a rule-based adaptation scheme. Due to its complexity, the problem was divided into three steps: preliminary implementation of the model (proof of concept); implementation of the complete model and investigation of the model solution; and model validation. The paper describes the first of these three steps. The model was implemented as a discrete-states machine, and the few parameters required were derived from the literature. It was then applied to a real clinical case. The study was conducted using the frictional contact finite element model of a human femur implanted with a cementless anatomical stem. A stable solution was achieved after between three and 15 iterations for all initial positions considered. Similar initial conditions yielded similar final configurations. The model predicted all initial configurations, with the exception of a partial osseo-integration, ranging between 62% (distal fit) and 78% (proximal fit) of the viable interface. This is in good agreement with the values reported in the literature that never exceed 75%, even in the best conditions, and report better clinical results for proximal fit. For the varus configuration, which lacks cortical support, the algorithm predicted a completed loosening.

Original languageEnglish
Pages (from-to)222-229
Number of pages8
JournalMedical and Biological Engineering and Computing
Volume42
Issue number2
DOIs
Publication statusPublished - Mar 2004

Fingerprint

Femur
Equipment and Supplies
Prosthetics
Numerical models

Keywords

  • Cementless stem
  • Implant fitting
  • Numerical model
  • Osseo-integration
  • Secondary stability

ASJC Scopus subject areas

  • Biomedical Engineering
  • Health Informatics
  • Health Information Management
  • Computer Science Applications
  • Computational Theory and Mathematics

Cite this

Effect of the initial implant fitting on the predicted secondary stability of a cementless stem. / Viceconti, Marco; Pancanti, A.; Dotti, M.; Traina, F.; Cristofolini, L.

In: Medical and Biological Engineering and Computing, Vol. 42, No. 2, 03.2004, p. 222-229.

Research output: Contribution to journalArticle

@article{522e3c465d2a47fba9d0ebf19f8cc791,
title = "Effect of the initial implant fitting on the predicted secondary stability of a cementless stem",
abstract = "A numerical model able to investigate the influence of biomechanical factors of the long-term secondary stability of implants would be extremely useful for the design of new cementless prosthetic devices. A purely biomechanical model of osseo-integration has been developed, formulated as a rule-based adaptation scheme. Due to its complexity, the problem was divided into three steps: preliminary implementation of the model (proof of concept); implementation of the complete model and investigation of the model solution; and model validation. The paper describes the first of these three steps. The model was implemented as a discrete-states machine, and the few parameters required were derived from the literature. It was then applied to a real clinical case. The study was conducted using the frictional contact finite element model of a human femur implanted with a cementless anatomical stem. A stable solution was achieved after between three and 15 iterations for all initial positions considered. Similar initial conditions yielded similar final configurations. The model predicted all initial configurations, with the exception of a partial osseo-integration, ranging between 62{\%} (distal fit) and 78{\%} (proximal fit) of the viable interface. This is in good agreement with the values reported in the literature that never exceed 75{\%}, even in the best conditions, and report better clinical results for proximal fit. For the varus configuration, which lacks cortical support, the algorithm predicted a completed loosening.",
keywords = "Cementless stem, Implant fitting, Numerical model, Osseo-integration, Secondary stability",
author = "Marco Viceconti and A. Pancanti and M. Dotti and F. Traina and L. Cristofolini",
year = "2004",
month = "3",
doi = "10.1007/BF02344635",
language = "English",
volume = "42",
pages = "222--229",
journal = "Medical and Biological Engineering and Computing",
issn = "0140-0118",
publisher = "Springer Verlag",
number = "2",

}

TY - JOUR

T1 - Effect of the initial implant fitting on the predicted secondary stability of a cementless stem

AU - Viceconti, Marco

AU - Pancanti, A.

AU - Dotti, M.

AU - Traina, F.

AU - Cristofolini, L.

PY - 2004/3

Y1 - 2004/3

N2 - A numerical model able to investigate the influence of biomechanical factors of the long-term secondary stability of implants would be extremely useful for the design of new cementless prosthetic devices. A purely biomechanical model of osseo-integration has been developed, formulated as a rule-based adaptation scheme. Due to its complexity, the problem was divided into three steps: preliminary implementation of the model (proof of concept); implementation of the complete model and investigation of the model solution; and model validation. The paper describes the first of these three steps. The model was implemented as a discrete-states machine, and the few parameters required were derived from the literature. It was then applied to a real clinical case. The study was conducted using the frictional contact finite element model of a human femur implanted with a cementless anatomical stem. A stable solution was achieved after between three and 15 iterations for all initial positions considered. Similar initial conditions yielded similar final configurations. The model predicted all initial configurations, with the exception of a partial osseo-integration, ranging between 62% (distal fit) and 78% (proximal fit) of the viable interface. This is in good agreement with the values reported in the literature that never exceed 75%, even in the best conditions, and report better clinical results for proximal fit. For the varus configuration, which lacks cortical support, the algorithm predicted a completed loosening.

AB - A numerical model able to investigate the influence of biomechanical factors of the long-term secondary stability of implants would be extremely useful for the design of new cementless prosthetic devices. A purely biomechanical model of osseo-integration has been developed, formulated as a rule-based adaptation scheme. Due to its complexity, the problem was divided into three steps: preliminary implementation of the model (proof of concept); implementation of the complete model and investigation of the model solution; and model validation. The paper describes the first of these three steps. The model was implemented as a discrete-states machine, and the few parameters required were derived from the literature. It was then applied to a real clinical case. The study was conducted using the frictional contact finite element model of a human femur implanted with a cementless anatomical stem. A stable solution was achieved after between three and 15 iterations for all initial positions considered. Similar initial conditions yielded similar final configurations. The model predicted all initial configurations, with the exception of a partial osseo-integration, ranging between 62% (distal fit) and 78% (proximal fit) of the viable interface. This is in good agreement with the values reported in the literature that never exceed 75%, even in the best conditions, and report better clinical results for proximal fit. For the varus configuration, which lacks cortical support, the algorithm predicted a completed loosening.

KW - Cementless stem

KW - Implant fitting

KW - Numerical model

KW - Osseo-integration

KW - Secondary stability

UR - http://www.scopus.com/inward/record.url?scp=2342488765&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=2342488765&partnerID=8YFLogxK

U2 - 10.1007/BF02344635

DO - 10.1007/BF02344635

M3 - Article

VL - 42

SP - 222

EP - 229

JO - Medical and Biological Engineering and Computing

JF - Medical and Biological Engineering and Computing

SN - 0140-0118

IS - 2

ER -