Effects of anesthesia on the response to sleep deprivation

Aaron B. Nelson, Ugo Faraguna, Giulio Tononi, Chiara Cirelli

Research output: Contribution to journalArticle

35 Citations (Scopus)

Abstract

Study Objective: Slow wave activity (SWA) during NREM sleep is the best characterized marker of sleep homeostasis, and the occurrence of sleep slow waves is necessary to reduce sleep need. Recent evidence suggests that sleep slow waves may mediate several beneficial effects of sleep on performance, from the prevention of cognitive impairments to memory consolidation. However, slow waves are also triggered by low doses of many anesthetics, but very few reports have examined whether anesthesia-mediated slow waves affect the homeostatic regulation of sleep. Moreover, no study has examined how sleep is affected by higher doses of anesthetics, which lead to a predominantly " isoelectric" EEG tracing without slow waves. Design: We studied in rats whether 1 hour of a dose of isoflurane or desflurane able to induce almost continuous slow waves (ISO-sw, DES-sw), and of a dose of desflurane resulting in a predominantly isoelectric EEG (DES-iso) reduces the sleep pressure caused by 4 h of sleep deprivation. Anesthesia was compared to a mock condition in which rats were only anesthetized for 2-3 min. Setting: Basic sleep research laboratory. Patients or Participants: Male WKY rats (n = 31). Interventions: Total sleep deprivation by exposure to novel objects starting at light onset, followed by one hour of anesthesia or mock anesthesia. Measurements and Results: One hour of anesthesia (sw or iso) did not affect either sleep duration or the overall sleep pattern. Anesthesia with ISO-sw or DES-sw, both associated with the occurrence of almost continuous slow waves, reduced the SWA rebound expected following 4 h of sleep deprivation. One hour of anesthesia with DES-iso, associated with isoelectric EEG and few slow waves, also reduced the SWA rebound after sleep deprivation, and did so to an extent similar to that observed after DES-sw. However, in contrast to DES-sw, SWA after DES-iso remained chronically lower than in baseline, resulting in reduced slow wave energy (SWE, SWA x time) for at least 2 days. Conclusion: The blunted SWA rebound after ISO-sw and DES-sw suggests that anesthesia slow waves may substitute for sleep slow waves. The reduced SWA rebound after DES-iso may reflect a pathological condition that results in a chronic decrease in SWA, or may suggest that anesthesia slow waves are not an absolute requirement to discharge sleep pressure.

Original languageEnglish
Pages (from-to)1659-1667
Number of pages9
JournalSleep
Volume33
Issue number12
Publication statusPublished - Dec 1 2010

Fingerprint

Sleep Deprivation
Sleep
Anesthesia
Electroencephalography
Anesthetics
Pressure
Inbred WKY Rats
Isoflurane

Keywords

  • Desflurane
  • Isoflurane
  • Rat
  • Slow wave activity

ASJC Scopus subject areas

  • Physiology (medical)
  • Clinical Neurology

Cite this

Nelson, A. B., Faraguna, U., Tononi, G., & Cirelli, C. (2010). Effects of anesthesia on the response to sleep deprivation. Sleep, 33(12), 1659-1667.

Effects of anesthesia on the response to sleep deprivation. / Nelson, Aaron B.; Faraguna, Ugo; Tononi, Giulio; Cirelli, Chiara.

In: Sleep, Vol. 33, No. 12, 01.12.2010, p. 1659-1667.

Research output: Contribution to journalArticle

Nelson, AB, Faraguna, U, Tononi, G & Cirelli, C 2010, 'Effects of anesthesia on the response to sleep deprivation', Sleep, vol. 33, no. 12, pp. 1659-1667.
Nelson AB, Faraguna U, Tononi G, Cirelli C. Effects of anesthesia on the response to sleep deprivation. Sleep. 2010 Dec 1;33(12):1659-1667.
Nelson, Aaron B. ; Faraguna, Ugo ; Tononi, Giulio ; Cirelli, Chiara. / Effects of anesthesia on the response to sleep deprivation. In: Sleep. 2010 ; Vol. 33, No. 12. pp. 1659-1667.
@article{cb82f43182d44fa98bed65b14398da70,
title = "Effects of anesthesia on the response to sleep deprivation",
abstract = "Study Objective: Slow wave activity (SWA) during NREM sleep is the best characterized marker of sleep homeostasis, and the occurrence of sleep slow waves is necessary to reduce sleep need. Recent evidence suggests that sleep slow waves may mediate several beneficial effects of sleep on performance, from the prevention of cognitive impairments to memory consolidation. However, slow waves are also triggered by low doses of many anesthetics, but very few reports have examined whether anesthesia-mediated slow waves affect the homeostatic regulation of sleep. Moreover, no study has examined how sleep is affected by higher doses of anesthetics, which lead to a predominantly {"} isoelectric{"} EEG tracing without slow waves. Design: We studied in rats whether 1 hour of a dose of isoflurane or desflurane able to induce almost continuous slow waves (ISO-sw, DES-sw), and of a dose of desflurane resulting in a predominantly isoelectric EEG (DES-iso) reduces the sleep pressure caused by 4 h of sleep deprivation. Anesthesia was compared to a mock condition in which rats were only anesthetized for 2-3 min. Setting: Basic sleep research laboratory. Patients or Participants: Male WKY rats (n = 31). Interventions: Total sleep deprivation by exposure to novel objects starting at light onset, followed by one hour of anesthesia or mock anesthesia. Measurements and Results: One hour of anesthesia (sw or iso) did not affect either sleep duration or the overall sleep pattern. Anesthesia with ISO-sw or DES-sw, both associated with the occurrence of almost continuous slow waves, reduced the SWA rebound expected following 4 h of sleep deprivation. One hour of anesthesia with DES-iso, associated with isoelectric EEG and few slow waves, also reduced the SWA rebound after sleep deprivation, and did so to an extent similar to that observed after DES-sw. However, in contrast to DES-sw, SWA after DES-iso remained chronically lower than in baseline, resulting in reduced slow wave energy (SWE, SWA x time) for at least 2 days. Conclusion: The blunted SWA rebound after ISO-sw and DES-sw suggests that anesthesia slow waves may substitute for sleep slow waves. The reduced SWA rebound after DES-iso may reflect a pathological condition that results in a chronic decrease in SWA, or may suggest that anesthesia slow waves are not an absolute requirement to discharge sleep pressure.",
keywords = "Desflurane, Isoflurane, Rat, Slow wave activity",
author = "Nelson, {Aaron B.} and Ugo Faraguna and Giulio Tononi and Chiara Cirelli",
year = "2010",
month = "12",
day = "1",
language = "English",
volume = "33",
pages = "1659--1667",
journal = "Sleep",
issn = "0161-8105",
publisher = "American Academy of Sleep Medicine",
number = "12",

}

TY - JOUR

T1 - Effects of anesthesia on the response to sleep deprivation

AU - Nelson, Aaron B.

AU - Faraguna, Ugo

AU - Tononi, Giulio

AU - Cirelli, Chiara

PY - 2010/12/1

Y1 - 2010/12/1

N2 - Study Objective: Slow wave activity (SWA) during NREM sleep is the best characterized marker of sleep homeostasis, and the occurrence of sleep slow waves is necessary to reduce sleep need. Recent evidence suggests that sleep slow waves may mediate several beneficial effects of sleep on performance, from the prevention of cognitive impairments to memory consolidation. However, slow waves are also triggered by low doses of many anesthetics, but very few reports have examined whether anesthesia-mediated slow waves affect the homeostatic regulation of sleep. Moreover, no study has examined how sleep is affected by higher doses of anesthetics, which lead to a predominantly " isoelectric" EEG tracing without slow waves. Design: We studied in rats whether 1 hour of a dose of isoflurane or desflurane able to induce almost continuous slow waves (ISO-sw, DES-sw), and of a dose of desflurane resulting in a predominantly isoelectric EEG (DES-iso) reduces the sleep pressure caused by 4 h of sleep deprivation. Anesthesia was compared to a mock condition in which rats were only anesthetized for 2-3 min. Setting: Basic sleep research laboratory. Patients or Participants: Male WKY rats (n = 31). Interventions: Total sleep deprivation by exposure to novel objects starting at light onset, followed by one hour of anesthesia or mock anesthesia. Measurements and Results: One hour of anesthesia (sw or iso) did not affect either sleep duration or the overall sleep pattern. Anesthesia with ISO-sw or DES-sw, both associated with the occurrence of almost continuous slow waves, reduced the SWA rebound expected following 4 h of sleep deprivation. One hour of anesthesia with DES-iso, associated with isoelectric EEG and few slow waves, also reduced the SWA rebound after sleep deprivation, and did so to an extent similar to that observed after DES-sw. However, in contrast to DES-sw, SWA after DES-iso remained chronically lower than in baseline, resulting in reduced slow wave energy (SWE, SWA x time) for at least 2 days. Conclusion: The blunted SWA rebound after ISO-sw and DES-sw suggests that anesthesia slow waves may substitute for sleep slow waves. The reduced SWA rebound after DES-iso may reflect a pathological condition that results in a chronic decrease in SWA, or may suggest that anesthesia slow waves are not an absolute requirement to discharge sleep pressure.

AB - Study Objective: Slow wave activity (SWA) during NREM sleep is the best characterized marker of sleep homeostasis, and the occurrence of sleep slow waves is necessary to reduce sleep need. Recent evidence suggests that sleep slow waves may mediate several beneficial effects of sleep on performance, from the prevention of cognitive impairments to memory consolidation. However, slow waves are also triggered by low doses of many anesthetics, but very few reports have examined whether anesthesia-mediated slow waves affect the homeostatic regulation of sleep. Moreover, no study has examined how sleep is affected by higher doses of anesthetics, which lead to a predominantly " isoelectric" EEG tracing without slow waves. Design: We studied in rats whether 1 hour of a dose of isoflurane or desflurane able to induce almost continuous slow waves (ISO-sw, DES-sw), and of a dose of desflurane resulting in a predominantly isoelectric EEG (DES-iso) reduces the sleep pressure caused by 4 h of sleep deprivation. Anesthesia was compared to a mock condition in which rats were only anesthetized for 2-3 min. Setting: Basic sleep research laboratory. Patients or Participants: Male WKY rats (n = 31). Interventions: Total sleep deprivation by exposure to novel objects starting at light onset, followed by one hour of anesthesia or mock anesthesia. Measurements and Results: One hour of anesthesia (sw or iso) did not affect either sleep duration or the overall sleep pattern. Anesthesia with ISO-sw or DES-sw, both associated with the occurrence of almost continuous slow waves, reduced the SWA rebound expected following 4 h of sleep deprivation. One hour of anesthesia with DES-iso, associated with isoelectric EEG and few slow waves, also reduced the SWA rebound after sleep deprivation, and did so to an extent similar to that observed after DES-sw. However, in contrast to DES-sw, SWA after DES-iso remained chronically lower than in baseline, resulting in reduced slow wave energy (SWE, SWA x time) for at least 2 days. Conclusion: The blunted SWA rebound after ISO-sw and DES-sw suggests that anesthesia slow waves may substitute for sleep slow waves. The reduced SWA rebound after DES-iso may reflect a pathological condition that results in a chronic decrease in SWA, or may suggest that anesthesia slow waves are not an absolute requirement to discharge sleep pressure.

KW - Desflurane

KW - Isoflurane

KW - Rat

KW - Slow wave activity

UR - http://www.scopus.com/inward/record.url?scp=78649877847&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=78649877847&partnerID=8YFLogxK

M3 - Article

C2 - 21120128

AN - SCOPUS:78649877847

VL - 33

SP - 1659

EP - 1667

JO - Sleep

JF - Sleep

SN - 0161-8105

IS - 12

ER -