APPROCCIO ELETTROFISIOLOGICO ALLE EPILESSIE FOCALI: INTRODUZIONE

Translated title of the contribution: Electrophysiological approach to focal epilepsy: Introduction

G. Avanzini

Research output: Contribution to journalArticle

Abstract

Epileptiform discharges resulting from spatial and temporal summation of individual neuron activities can be detected by EEG and stereo-EEG recordings. The EEG sensitivity can be considered satisfactory while its localization power is often poor. Recent advances in EEG analysis open interesting perspectives. The value and limitations of EEG with respect to depth (stereo-EEG) recordings are discussed in the following papers.

Original languageItalian
Pages (from-to)381
Number of pages1
JournalBollettino - Lega Italiana contro l'Epilessia
Issue number86-87
Publication statusPublished - 1994

Fingerprint

Partial Epilepsy
Electroencephalography
Neurons

ASJC Scopus subject areas

  • Clinical Neurology

Cite this

APPROCCIO ELETTROFISIOLOGICO ALLE EPILESSIE FOCALI : INTRODUZIONE. / Avanzini, G.

In: Bollettino - Lega Italiana contro l'Epilessia, No. 86-87, 1994, p. 381.

Research output: Contribution to journalArticle

@article{eaae94b969cb46c19b5aa419bea03779,
title = "APPROCCIO ELETTROFISIOLOGICO ALLE EPILESSIE FOCALI: INTRODUZIONE",
abstract = "Epileptiform discharges resulting from spatial and temporal summation of individual neuron activities can be detected by EEG and stereo-EEG recordings. The EEG sensitivity can be considered satisfactory while its localization power is often poor. Recent advances in EEG analysis open interesting perspectives. The value and limitations of EEG with respect to depth (stereo-EEG) recordings are discussed in the following papers.",
author = "G. Avanzini",
year = "1994",
language = "Italian",
pages = "381",
journal = "Bollettino - Lega Italiana contro l'Epilessia",
issn = "0394-560X",
publisher = "Lega Italiana contro l'Epilessia",
number = "86-87",

}

TY - JOUR

T1 - APPROCCIO ELETTROFISIOLOGICO ALLE EPILESSIE FOCALI

T2 - INTRODUZIONE

AU - Avanzini, G.

PY - 1994

Y1 - 1994

N2 - Epileptiform discharges resulting from spatial and temporal summation of individual neuron activities can be detected by EEG and stereo-EEG recordings. The EEG sensitivity can be considered satisfactory while its localization power is often poor. Recent advances in EEG analysis open interesting perspectives. The value and limitations of EEG with respect to depth (stereo-EEG) recordings are discussed in the following papers.

AB - Epileptiform discharges resulting from spatial and temporal summation of individual neuron activities can be detected by EEG and stereo-EEG recordings. The EEG sensitivity can be considered satisfactory while its localization power is often poor. Recent advances in EEG analysis open interesting perspectives. The value and limitations of EEG with respect to depth (stereo-EEG) recordings are discussed in the following papers.

UR - http://www.scopus.com/inward/record.url?scp=0028676027&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028676027&partnerID=8YFLogxK

M3 - Articolo

AN - SCOPUS:0028676027

SP - 381

JO - Bollettino - Lega Italiana contro l'Epilessia

JF - Bollettino - Lega Italiana contro l'Epilessia

SN - 0394-560X

IS - 86-87

ER -