A laboratory and on-the-field study was conducted to compare Floor-Based (FB) and Ceiling-Based (CB) patients transfer devices. Pushing and pulling forces were measured by means of computer assisted dynamometer. EMG signals were measured. Standardized patient transfers were setup in the room (bed-chair-door-return). FB devices showed pushing and pulling forces higher than CB ones. CB paths were the smoothest and EMG data related to upper arms and trunk muscles showed stable lower loads for CB. The study suggests that CB patient transfer devices reduced the load. CBs seem the best tools for patient handling.

Original languageItalian
Pages (from-to)230-234
Number of pages5
JournalGiornale Italiano di Medicina del Lavoro ed Ergonomia
Volume33
Issue numberSUPPL. 3
Publication statusPublished - Jul 2011

Fingerprint

Patient Transfer
Equipment and Supplies
Moving and Lifting Patients
Arm
Muscles

ASJC Scopus subject areas

  • Public Health, Environmental and Occupational Health

Cite this

EMG e forze applicate durante l'utilizzo dei sollevatori per pazienti di tipo carrellato e a soffitto. / De Vito, G.; Meroni, R.; Riva, Ma; Mauri, R.; Giunco, F.; Conti, S.; Cesana, G. C.

In: Giornale Italiano di Medicina del Lavoro ed Ergonomia, Vol. 33, No. SUPPL. 3, 07.2011, p. 230-234.

Research output: Contribution to journalArticle

De Vito, G, Meroni, R, Riva, M, Mauri, R, Giunco, F, Conti, S & Cesana, GC 2011, 'EMG e forze applicate durante l'utilizzo dei sollevatori per pazienti di tipo carrellato e a soffitto', Giornale Italiano di Medicina del Lavoro ed Ergonomia, vol. 33, no. SUPPL. 3, pp. 230-234.
De Vito, G. ; Meroni, R. ; Riva, Ma ; Mauri, R. ; Giunco, F. ; Conti, S. ; Cesana, G. C. / EMG e forze applicate durante l'utilizzo dei sollevatori per pazienti di tipo carrellato e a soffitto. In: Giornale Italiano di Medicina del Lavoro ed Ergonomia. 2011 ; Vol. 33, No. SUPPL. 3. pp. 230-234.
@article{8aee8e6f121e45ce98b2fc4abda429c0,
title = "EMG e forze applicate durante l'utilizzo dei sollevatori per pazienti di tipo carrellato e a soffitto",
abstract = "A laboratory and on-the-field study was conducted to compare Floor-Based (FB) and Ceiling-Based (CB) patients transfer devices. Pushing and pulling forces were measured by means of computer assisted dynamometer. EMG signals were measured. Standardized patient transfers were setup in the room (bed-chair-door-return). FB devices showed pushing and pulling forces higher than CB ones. CB paths were the smoothest and EMG data related to upper arms and trunk muscles showed stable lower loads for CB. The study suggests that CB patient transfer devices reduced the load. CBs seem the best tools for patient handling.",
keywords = "EMG, Patients transfer devices, Pushing and pulling",
author = "{De Vito}, G. and R. Meroni and Ma Riva and R. Mauri and F. Giunco and S. Conti and Cesana, {G. C.}",
year = "2011",
month = "7",
language = "Italian",
volume = "33",
pages = "230--234",
journal = "Giornale Italiano di Medicina del Lavoro ed Ergonomia",
issn = "1592-7830",
publisher = "Tipografia PI-ME Editrice Srl",
number = "SUPPL. 3",

}

TY - JOUR

T1 - EMG e forze applicate durante l'utilizzo dei sollevatori per pazienti di tipo carrellato e a soffitto

AU - De Vito, G.

AU - Meroni, R.

AU - Riva, Ma

AU - Mauri, R.

AU - Giunco, F.

AU - Conti, S.

AU - Cesana, G. C.

PY - 2011/7

Y1 - 2011/7

N2 - A laboratory and on-the-field study was conducted to compare Floor-Based (FB) and Ceiling-Based (CB) patients transfer devices. Pushing and pulling forces were measured by means of computer assisted dynamometer. EMG signals were measured. Standardized patient transfers were setup in the room (bed-chair-door-return). FB devices showed pushing and pulling forces higher than CB ones. CB paths were the smoothest and EMG data related to upper arms and trunk muscles showed stable lower loads for CB. The study suggests that CB patient transfer devices reduced the load. CBs seem the best tools for patient handling.

AB - A laboratory and on-the-field study was conducted to compare Floor-Based (FB) and Ceiling-Based (CB) patients transfer devices. Pushing and pulling forces were measured by means of computer assisted dynamometer. EMG signals were measured. Standardized patient transfers were setup in the room (bed-chair-door-return). FB devices showed pushing and pulling forces higher than CB ones. CB paths were the smoothest and EMG data related to upper arms and trunk muscles showed stable lower loads for CB. The study suggests that CB patient transfer devices reduced the load. CBs seem the best tools for patient handling.

KW - EMG

KW - Patients transfer devices

KW - Pushing and pulling

UR - http://www.scopus.com/inward/record.url?scp=84866923482&partnerID=8YFLogxK