European Concerted Action on Anticoagulation (ECAA). Minimum number of centres for reliable International Sensitivity Index calibration of CoaguChek and TAS point-of-care whole blood monitors

L. Poller, M. Keown, N. Chauhan, A. M H P Van den Besselaar, A. Tripodi, C. Shiach, J. Jespersen

Research output: Contribution to journalArticle

Abstract

Introduction: Prothrombin time (PT) test systems require multicentre calibration for reliable International Sensitivity Index (ISI). Multicentre calibration of CoaguChek Mini and TAS PT-NC point-of-care test (POCT) systems is less precise than conventional PT testing. The aim of the present study was to determine the number of centres required to give reliable ISI and International Normalised Ratio (INR) with these two POCT whole blood PT monitors. Materials and methods: A simulation study, based on results of a 10-centre calibration exercise, was performed to assess reliability of ISI and INR when the number of centres was reduced from 10 to 2. Results and Conclusions: With both systems, the range of ISI and INR deviation increased as the number of centres was reduced. For the CoaguChek Mini, at least five centres were needed for satisfactory INR deviation in 95% of calibrations. With the TAS PT-NC, three centres gave satisfactory INR at this level. The number of centres required for multicentre calibration of these two POCT PT systems is greater than the two proposed by World Health Organisation (WHO) Guidelines for conventional PT testing.

Original languageEnglish
Pages (from-to)61-66
Number of pages6
JournalThrombosis Research
Volume107
Issue number1-2
DOIs
Publication statusPublished - Jul 15 2002

Fingerprint

Point-of-Care Systems
Prothrombin Time
Calibration
International Normalized Ratio
Hematologic Tests
Guidelines

Keywords

  • INR
  • ISI
  • Minimum centres
  • POCT PT monitors
  • Prothrombin time

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Hematology

Cite this

European Concerted Action on Anticoagulation (ECAA). Minimum number of centres for reliable International Sensitivity Index calibration of CoaguChek and TAS point-of-care whole blood monitors. / Poller, L.; Keown, M.; Chauhan, N.; Van den Besselaar, A. M H P; Tripodi, A.; Shiach, C.; Jespersen, J.

In: Thrombosis Research, Vol. 107, No. 1-2, 15.07.2002, p. 61-66.

Research output: Contribution to journalArticle

@article{053caae8c8684e73a87777a830e64e46,
title = "European Concerted Action on Anticoagulation (ECAA). Minimum number of centres for reliable International Sensitivity Index calibration of CoaguChek and TAS point-of-care whole blood monitors",
abstract = "Introduction: Prothrombin time (PT) test systems require multicentre calibration for reliable International Sensitivity Index (ISI). Multicentre calibration of CoaguChek Mini and TAS PT-NC point-of-care test (POCT) systems is less precise than conventional PT testing. The aim of the present study was to determine the number of centres required to give reliable ISI and International Normalised Ratio (INR) with these two POCT whole blood PT monitors. Materials and methods: A simulation study, based on results of a 10-centre calibration exercise, was performed to assess reliability of ISI and INR when the number of centres was reduced from 10 to 2. Results and Conclusions: With both systems, the range of ISI and INR deviation increased as the number of centres was reduced. For the CoaguChek Mini, at least five centres were needed for satisfactory INR deviation in 95{\%} of calibrations. With the TAS PT-NC, three centres gave satisfactory INR at this level. The number of centres required for multicentre calibration of these two POCT PT systems is greater than the two proposed by World Health Organisation (WHO) Guidelines for conventional PT testing.",
keywords = "INR, ISI, Minimum centres, POCT PT monitors, Prothrombin time",
author = "L. Poller and M. Keown and N. Chauhan and {Van den Besselaar}, {A. M H P} and A. Tripodi and C. Shiach and J. Jespersen",
year = "2002",
month = "7",
day = "15",
doi = "10.1016/S0049-3848(02)00179-2",
language = "English",
volume = "107",
pages = "61--66",
journal = "Thrombosis Research",
issn = "0049-3848",
publisher = "Elsevier Limited",
number = "1-2",

}

TY - JOUR

T1 - European Concerted Action on Anticoagulation (ECAA). Minimum number of centres for reliable International Sensitivity Index calibration of CoaguChek and TAS point-of-care whole blood monitors

AU - Poller, L.

AU - Keown, M.

AU - Chauhan, N.

AU - Van den Besselaar, A. M H P

AU - Tripodi, A.

AU - Shiach, C.

AU - Jespersen, J.

PY - 2002/7/15

Y1 - 2002/7/15

N2 - Introduction: Prothrombin time (PT) test systems require multicentre calibration for reliable International Sensitivity Index (ISI). Multicentre calibration of CoaguChek Mini and TAS PT-NC point-of-care test (POCT) systems is less precise than conventional PT testing. The aim of the present study was to determine the number of centres required to give reliable ISI and International Normalised Ratio (INR) with these two POCT whole blood PT monitors. Materials and methods: A simulation study, based on results of a 10-centre calibration exercise, was performed to assess reliability of ISI and INR when the number of centres was reduced from 10 to 2. Results and Conclusions: With both systems, the range of ISI and INR deviation increased as the number of centres was reduced. For the CoaguChek Mini, at least five centres were needed for satisfactory INR deviation in 95% of calibrations. With the TAS PT-NC, three centres gave satisfactory INR at this level. The number of centres required for multicentre calibration of these two POCT PT systems is greater than the two proposed by World Health Organisation (WHO) Guidelines for conventional PT testing.

AB - Introduction: Prothrombin time (PT) test systems require multicentre calibration for reliable International Sensitivity Index (ISI). Multicentre calibration of CoaguChek Mini and TAS PT-NC point-of-care test (POCT) systems is less precise than conventional PT testing. The aim of the present study was to determine the number of centres required to give reliable ISI and International Normalised Ratio (INR) with these two POCT whole blood PT monitors. Materials and methods: A simulation study, based on results of a 10-centre calibration exercise, was performed to assess reliability of ISI and INR when the number of centres was reduced from 10 to 2. Results and Conclusions: With both systems, the range of ISI and INR deviation increased as the number of centres was reduced. For the CoaguChek Mini, at least five centres were needed for satisfactory INR deviation in 95% of calibrations. With the TAS PT-NC, three centres gave satisfactory INR at this level. The number of centres required for multicentre calibration of these two POCT PT systems is greater than the two proposed by World Health Organisation (WHO) Guidelines for conventional PT testing.

KW - INR

KW - ISI

KW - Minimum centres

KW - POCT PT monitors

KW - Prothrombin time

UR - http://www.scopus.com/inward/record.url?scp=0037101573&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0037101573&partnerID=8YFLogxK

U2 - 10.1016/S0049-3848(02)00179-2

DO - 10.1016/S0049-3848(02)00179-2

M3 - Article

C2 - 12413591

AN - SCOPUS:0037101573

VL - 107

SP - 61

EP - 66

JO - Thrombosis Research

JF - Thrombosis Research

SN - 0049-3848

IS - 1-2

ER -