Evaluation of the performance of an immunoturbidimetric HbA1c reagent applied to the Siemens ADVIA 2400 automatic analyzer

Mosé Barbaro, Carlos Ku-Chulim, Fran Johnston, Rebecca Cochrane, Fabio Rota, Gabriella Passerini, Elena Guerra, Ferruccio Ceriotti, Anna Carobene

Research output: Contribution to journalArticle

Abstract

Objectives: A new immunochemical reagent based on latex particles and antibodies against HbA1c (Axis-Shield), using Siemens ADVIA 2400 Instrument was evaluated. Design and methods: Intra-assay and total imprecision, interferences studies (bilirubin ~. 850. μmol/L, triglycerides ~ 16.9. mmol/L, total protein ~ 140. g/L, sodium cyanate ~ 50. mg/dL, ascorbic acid ~ 50. mg/dL, urea ~ 24.99. mmol/L, glucose ~ 105.46. mmol/L, rheumatoid factor ~ 600. U/mL), method comparison vs Capillary Electrophoresis (Sebia), Lot to Lot reproducibility, linearity and carry over were conducted on ADVIA 2400 according to CLSI protocols. Additionally, 40 samples were measured by the two methods and also by a NGSP reference lab. Results: CVs % obtained by intra-assay imprecision, on 3 human HbA1c specimens at different concentrations (48, 48-64 and >. 64. mmol/mol) in 20 replicates, were <4%. CVs % by total imprecision, performed over 20. days with 4 calibrations on 3 human HbA1c samples (48, 48-64 and > 64. mmol/mol), resulted <4%. Interferences were studied on two human samples (42-53 and. > 64. mmol/mol) without obtaining significant biases (<10%). Methods comparison vs Capillary Electrophoresis, performed on 120 samples ranging 23-137. mmol/mol, obtaining r. = 0.974 as regression coefficient and a mean bias at decision level (48. mmol/mol) <3%. The results obtained with the NGSP samples have allowed the certification of the new reagent. Conclusions: The ASD reagent met the needs of clinical laboratories, fulfilling both NGSP and IFCC requirements and it is robust to endogenous interferences.

Original languageEnglish
Pages (from-to)177-180
Number of pages4
JournalClinical Biochemistry
Volume48
Issue number3
DOIs
Publication statusPublished - Feb 1 2015

Keywords

  • Capillary electrophoresis
  • CLSI
  • Glycated hemoglobin
  • Immunoassay
  • Method evaluation
  • NGSP

ASJC Scopus subject areas

  • Clinical Biochemistry
  • Medicine(all)

Fingerprint Dive into the research topics of 'Evaluation of the performance of an immunoturbidimetric HbA1c reagent applied to the Siemens ADVIA 2400 automatic analyzer'. Together they form a unique fingerprint.

  • Cite this