Gamma camera calibration and validation for quantitative SPECT imaging with 177Lu

M. D'Arienzo, M. Cazzato, M. L. Cozzella, M. Cox, Marco D'Andrea, A. Fazio, A. Fenwick, G. Iaccarino, L. Johansson, L. Strigari, S. Ungania, P. De Felice

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Over the last years 177Lu has received considerable attention from the clinical nuclear medicine community thanks to its wide range of applications in molecular radiotherapy, especially in peptide-receptor radionuclide therapy (PRRT). In addition to short-range beta particles, 177Lu emits low energy gamma radiation of 113 keV and 208 keV that allows gamma camera quantitative imaging. Despite quantitative cancer imaging in molecular radiotherapy having been proven to be a key instrument for the assessment of therapeutic response, at present no general clinically accepted quantitative imaging protocol exists and absolute quantification studies are usually based on individual initiatives.The aim of this work was to develop and evaluate an approach to gamma camera calibration for absolute quantification in tomographic imaging with 177Lu. We assessed the gamma camera calibration factors for a Philips IRIX and Philips AXIS gamma camera system using various reference geometries, both in air and in water. Images were corrected for the major effects that contribute to image degradation, i.e. attenuation, scatter and dead- time. We validated our method in non-reference geometry using an anthropomorphic torso phantom provided with the liver cavity uniformly filled with 177LuCl3.Our results showed that calibration factors depend on the particular reference condition. In general, acquisitions performed with the IRIX gamma camera provided good results at 208 keV, with agreement within 5% for all geometries. The use of a Jaszczak 16 mL hollow sphere in water provided calibration factors capable of recovering the activity in anthropomorphic geometry within 1% for the 208 keV peak, for both gamma cameras. The point source provided the poorest results, most likely because scatter and attenuation correction are not incorporated in the calibration factor. However, for both gamma cameras all geometries provided calibration factors capable of recovering the activity in anthropomorphic geometry within about 10% (range -11.6% to +7.3%) for acquisitions at the 208 keV photopeak.As a general rule, scatter and attenuation play a much larger role at 113 keV compared to 208 keV and are likely to hinder an accurate absolute quantification. Acquisitions of only the 177Lu main photopeak (208 keV) are therefore recommended in clinical practice. Preliminary results suggest that the gamma camera calibration factor can be assessed with a standard uncertainty below (or of the order of) 3% if activity is determined with equipment traceable to primary standards, accurate volume measurements are made, and an appropriate chemical carrier is used to allow a homogeneous and stable solution to be used during the measurements.

Original languageEnglish
Pages (from-to)156-164
Number of pages9
JournalApplied Radiation and Isotopes
Volume112
DOIs
Publication statusPublished - Jun 1 2016

Fingerprint

cameras
geometry
photopeak
acquisition
attenuation
radiation therapy
torso
nuclear medicine
beta particles
liver
radioactive isotopes
water
point sources
peptides
hollow
therapy
cancer
gamma rays
degradation
cavities

Keywords

  • Calibration
  • Gamma camera
  • Molecular radiotherapy
  • Quantitative imaging
  • Radionuclide therapy

ASJC Scopus subject areas

  • Radiation

Cite this

Gamma camera calibration and validation for quantitative SPECT imaging with 177Lu. / D'Arienzo, M.; Cazzato, M.; Cozzella, M. L.; Cox, M.; D'Andrea, Marco; Fazio, A.; Fenwick, A.; Iaccarino, G.; Johansson, L.; Strigari, L.; Ungania, S.; De Felice, P.

In: Applied Radiation and Isotopes, Vol. 112, 01.06.2016, p. 156-164.

Research output: Contribution to journalArticle

D'Arienzo, M, Cazzato, M, Cozzella, ML, Cox, M, D'Andrea, M, Fazio, A, Fenwick, A, Iaccarino, G, Johansson, L, Strigari, L, Ungania, S & De Felice, P 2016, 'Gamma camera calibration and validation for quantitative SPECT imaging with 177Lu', Applied Radiation and Isotopes, vol. 112, pp. 156-164. https://doi.org/10.1016/j.apradiso.2016.03.007
D'Arienzo, M. ; Cazzato, M. ; Cozzella, M. L. ; Cox, M. ; D'Andrea, Marco ; Fazio, A. ; Fenwick, A. ; Iaccarino, G. ; Johansson, L. ; Strigari, L. ; Ungania, S. ; De Felice, P. / Gamma camera calibration and validation for quantitative SPECT imaging with 177Lu. In: Applied Radiation and Isotopes. 2016 ; Vol. 112. pp. 156-164.
@article{0ac7981082d34340a92be214a4c21d10,
title = "Gamma camera calibration and validation for quantitative SPECT imaging with 177Lu",
abstract = "Over the last years 177Lu has received considerable attention from the clinical nuclear medicine community thanks to its wide range of applications in molecular radiotherapy, especially in peptide-receptor radionuclide therapy (PRRT). In addition to short-range beta particles, 177Lu emits low energy gamma radiation of 113 keV and 208 keV that allows gamma camera quantitative imaging. Despite quantitative cancer imaging in molecular radiotherapy having been proven to be a key instrument for the assessment of therapeutic response, at present no general clinically accepted quantitative imaging protocol exists and absolute quantification studies are usually based on individual initiatives.The aim of this work was to develop and evaluate an approach to gamma camera calibration for absolute quantification in tomographic imaging with 177Lu. We assessed the gamma camera calibration factors for a Philips IRIX and Philips AXIS gamma camera system using various reference geometries, both in air and in water. Images were corrected for the major effects that contribute to image degradation, i.e. attenuation, scatter and dead- time. We validated our method in non-reference geometry using an anthropomorphic torso phantom provided with the liver cavity uniformly filled with 177LuCl3.Our results showed that calibration factors depend on the particular reference condition. In general, acquisitions performed with the IRIX gamma camera provided good results at 208 keV, with agreement within 5{\%} for all geometries. The use of a Jaszczak 16 mL hollow sphere in water provided calibration factors capable of recovering the activity in anthropomorphic geometry within 1{\%} for the 208 keV peak, for both gamma cameras. The point source provided the poorest results, most likely because scatter and attenuation correction are not incorporated in the calibration factor. However, for both gamma cameras all geometries provided calibration factors capable of recovering the activity in anthropomorphic geometry within about 10{\%} (range -11.6{\%} to +7.3{\%}) for acquisitions at the 208 keV photopeak.As a general rule, scatter and attenuation play a much larger role at 113 keV compared to 208 keV and are likely to hinder an accurate absolute quantification. Acquisitions of only the 177Lu main photopeak (208 keV) are therefore recommended in clinical practice. Preliminary results suggest that the gamma camera calibration factor can be assessed with a standard uncertainty below (or of the order of) 3{\%} if activity is determined with equipment traceable to primary standards, accurate volume measurements are made, and an appropriate chemical carrier is used to allow a homogeneous and stable solution to be used during the measurements.",
keywords = "Calibration, Gamma camera, Molecular radiotherapy, Quantitative imaging, Radionuclide therapy",
author = "M. D'Arienzo and M. Cazzato and Cozzella, {M. L.} and M. Cox and Marco D'Andrea and A. Fazio and A. Fenwick and G. Iaccarino and L. Johansson and L. Strigari and S. Ungania and {De Felice}, P.",
note = "se prendiamo un'altro del regina elena lo prendiamo intero",
year = "2016",
month = "6",
day = "1",
doi = "10.1016/j.apradiso.2016.03.007",
language = "English",
volume = "112",
pages = "156--164",
journal = "Applied Radiation and Isotopes",
issn = "0969-8043",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Gamma camera calibration and validation for quantitative SPECT imaging with 177Lu

AU - D'Arienzo, M.

AU - Cazzato, M.

AU - Cozzella, M. L.

AU - Cox, M.

AU - D'Andrea, Marco

AU - Fazio, A.

AU - Fenwick, A.

AU - Iaccarino, G.

AU - Johansson, L.

AU - Strigari, L.

AU - Ungania, S.

AU - De Felice, P.

N1 - se prendiamo un'altro del regina elena lo prendiamo intero

PY - 2016/6/1

Y1 - 2016/6/1

N2 - Over the last years 177Lu has received considerable attention from the clinical nuclear medicine community thanks to its wide range of applications in molecular radiotherapy, especially in peptide-receptor radionuclide therapy (PRRT). In addition to short-range beta particles, 177Lu emits low energy gamma radiation of 113 keV and 208 keV that allows gamma camera quantitative imaging. Despite quantitative cancer imaging in molecular radiotherapy having been proven to be a key instrument for the assessment of therapeutic response, at present no general clinically accepted quantitative imaging protocol exists and absolute quantification studies are usually based on individual initiatives.The aim of this work was to develop and evaluate an approach to gamma camera calibration for absolute quantification in tomographic imaging with 177Lu. We assessed the gamma camera calibration factors for a Philips IRIX and Philips AXIS gamma camera system using various reference geometries, both in air and in water. Images were corrected for the major effects that contribute to image degradation, i.e. attenuation, scatter and dead- time. We validated our method in non-reference geometry using an anthropomorphic torso phantom provided with the liver cavity uniformly filled with 177LuCl3.Our results showed that calibration factors depend on the particular reference condition. In general, acquisitions performed with the IRIX gamma camera provided good results at 208 keV, with agreement within 5% for all geometries. The use of a Jaszczak 16 mL hollow sphere in water provided calibration factors capable of recovering the activity in anthropomorphic geometry within 1% for the 208 keV peak, for both gamma cameras. The point source provided the poorest results, most likely because scatter and attenuation correction are not incorporated in the calibration factor. However, for both gamma cameras all geometries provided calibration factors capable of recovering the activity in anthropomorphic geometry within about 10% (range -11.6% to +7.3%) for acquisitions at the 208 keV photopeak.As a general rule, scatter and attenuation play a much larger role at 113 keV compared to 208 keV and are likely to hinder an accurate absolute quantification. Acquisitions of only the 177Lu main photopeak (208 keV) are therefore recommended in clinical practice. Preliminary results suggest that the gamma camera calibration factor can be assessed with a standard uncertainty below (or of the order of) 3% if activity is determined with equipment traceable to primary standards, accurate volume measurements are made, and an appropriate chemical carrier is used to allow a homogeneous and stable solution to be used during the measurements.

AB - Over the last years 177Lu has received considerable attention from the clinical nuclear medicine community thanks to its wide range of applications in molecular radiotherapy, especially in peptide-receptor radionuclide therapy (PRRT). In addition to short-range beta particles, 177Lu emits low energy gamma radiation of 113 keV and 208 keV that allows gamma camera quantitative imaging. Despite quantitative cancer imaging in molecular radiotherapy having been proven to be a key instrument for the assessment of therapeutic response, at present no general clinically accepted quantitative imaging protocol exists and absolute quantification studies are usually based on individual initiatives.The aim of this work was to develop and evaluate an approach to gamma camera calibration for absolute quantification in tomographic imaging with 177Lu. We assessed the gamma camera calibration factors for a Philips IRIX and Philips AXIS gamma camera system using various reference geometries, both in air and in water. Images were corrected for the major effects that contribute to image degradation, i.e. attenuation, scatter and dead- time. We validated our method in non-reference geometry using an anthropomorphic torso phantom provided with the liver cavity uniformly filled with 177LuCl3.Our results showed that calibration factors depend on the particular reference condition. In general, acquisitions performed with the IRIX gamma camera provided good results at 208 keV, with agreement within 5% for all geometries. The use of a Jaszczak 16 mL hollow sphere in water provided calibration factors capable of recovering the activity in anthropomorphic geometry within 1% for the 208 keV peak, for both gamma cameras. The point source provided the poorest results, most likely because scatter and attenuation correction are not incorporated in the calibration factor. However, for both gamma cameras all geometries provided calibration factors capable of recovering the activity in anthropomorphic geometry within about 10% (range -11.6% to +7.3%) for acquisitions at the 208 keV photopeak.As a general rule, scatter and attenuation play a much larger role at 113 keV compared to 208 keV and are likely to hinder an accurate absolute quantification. Acquisitions of only the 177Lu main photopeak (208 keV) are therefore recommended in clinical practice. Preliminary results suggest that the gamma camera calibration factor can be assessed with a standard uncertainty below (or of the order of) 3% if activity is determined with equipment traceable to primary standards, accurate volume measurements are made, and an appropriate chemical carrier is used to allow a homogeneous and stable solution to be used during the measurements.

KW - Calibration

KW - Gamma camera

KW - Molecular radiotherapy

KW - Quantitative imaging

KW - Radionuclide therapy

UR - http://www.scopus.com/inward/record.url?scp=84962699116&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84962699116&partnerID=8YFLogxK

U2 - 10.1016/j.apradiso.2016.03.007

DO - 10.1016/j.apradiso.2016.03.007

M3 - Article

AN - SCOPUS:84962699116

VL - 112

SP - 156

EP - 164

JO - Applied Radiation and Isotopes

JF - Applied Radiation and Isotopes

SN - 0969-8043

ER -