Generation of 4-dimensional CT images based on 4-dimensional PET-derived motion fields

Hadi J. Fayad, Frederic Lamare, Catherine Cheze Le Rest, Valentino Bettinardi, Dimitris Visvikis

Research output: Contribution to journalArticle

24 Citations (Scopus)

Abstract

Respiratory motion can potentially reduce accuracy in anatomic and functional image fusion from multimodality systems. It can blur the uptake of small lesions and lead to significant activity underestimation. Solutions presented to date include respiration- synchronized anatomic and functional acquisitions. To increase the signal-to-noise ratio of the synchronized PET images, methods using nonrigid transformations during the reconstruction process have been proposed. In most of these methods, 4-dimensional (4D) CT images were used to derive the required deformation matrices. However, variations between acquired 4D PET and corresponding CT image series due to differences in respiratory conditions during PET and CT acquisitions have been reported. In addition, the radiation dose burden resulting from a 4D CT acquisition may not be justifiable for every patient. Methods: In this paper, we present a method for the generation of dynamic CT images from the combination of one reference CT image and deformation matrices obtained from the elastic registration of 4D PET images not corrected for attenuation. On the one hand, our approach eliminates the need for the acquisition of dynamic CT. On the other hand, it also ensures a good match between CT and PET images, allowing accurate attenuation correction to be performed for respirationsynchronized PET acquisitions. Results: The proposed method was first validated on Monte Carlo-simulated datasets, and then on patient datasets (n 5 4) by comparing generated 4D CT images with the corresponding acquired original CT images. Different levels of PET image statistical quality were considered in order to investigate the impact of image noise in the derivation of the 4D CT series. Conclusion: Our results suggest that clinically relevant PET acquisition times can be used for the implementation of such an approach, making this an even more attractive solution considering the absence of the extra dose given by a standard 4D CT acquisition. Finally, this approach may be applicable to other multimodality devices such as PET/MR. COPYRIGHT

Original languageEnglish
Pages (from-to)631-638
Number of pages8
JournalJournal of Nuclear Medicine
Volume54
Issue number4
DOIs
Publication statusPublished - Apr 1 2013

Fingerprint

Signal-To-Noise Ratio
Respiration
Radiation
Equipment and Supplies
Datasets
Positron Emission Tomography Computed Tomography

Keywords

  • 4D PET/CT
  • Attenuation
  • Respiratory motion

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Generation of 4-dimensional CT images based on 4-dimensional PET-derived motion fields. / Fayad, Hadi J.; Lamare, Frederic; Le Rest, Catherine Cheze; Bettinardi, Valentino; Visvikis, Dimitris.

In: Journal of Nuclear Medicine, Vol. 54, No. 4, 01.04.2013, p. 631-638.

Research output: Contribution to journalArticle

Fayad, Hadi J. ; Lamare, Frederic ; Le Rest, Catherine Cheze ; Bettinardi, Valentino ; Visvikis, Dimitris. / Generation of 4-dimensional CT images based on 4-dimensional PET-derived motion fields. In: Journal of Nuclear Medicine. 2013 ; Vol. 54, No. 4. pp. 631-638.
@article{cdd257f574574a0db2f9e9f4089dc51c,
title = "Generation of 4-dimensional CT images based on 4-dimensional PET-derived motion fields",
abstract = "Respiratory motion can potentially reduce accuracy in anatomic and functional image fusion from multimodality systems. It can blur the uptake of small lesions and lead to significant activity underestimation. Solutions presented to date include respiration- synchronized anatomic and functional acquisitions. To increase the signal-to-noise ratio of the synchronized PET images, methods using nonrigid transformations during the reconstruction process have been proposed. In most of these methods, 4-dimensional (4D) CT images were used to derive the required deformation matrices. However, variations between acquired 4D PET and corresponding CT image series due to differences in respiratory conditions during PET and CT acquisitions have been reported. In addition, the radiation dose burden resulting from a 4D CT acquisition may not be justifiable for every patient. Methods: In this paper, we present a method for the generation of dynamic CT images from the combination of one reference CT image and deformation matrices obtained from the elastic registration of 4D PET images not corrected for attenuation. On the one hand, our approach eliminates the need for the acquisition of dynamic CT. On the other hand, it also ensures a good match between CT and PET images, allowing accurate attenuation correction to be performed for respirationsynchronized PET acquisitions. Results: The proposed method was first validated on Monte Carlo-simulated datasets, and then on patient datasets (n 5 4) by comparing generated 4D CT images with the corresponding acquired original CT images. Different levels of PET image statistical quality were considered in order to investigate the impact of image noise in the derivation of the 4D CT series. Conclusion: Our results suggest that clinically relevant PET acquisition times can be used for the implementation of such an approach, making this an even more attractive solution considering the absence of the extra dose given by a standard 4D CT acquisition. Finally, this approach may be applicable to other multimodality devices such as PET/MR. COPYRIGHT",
keywords = "4D PET/CT, Attenuation, Respiratory motion",
author = "Fayad, {Hadi J.} and Frederic Lamare and {Le Rest}, {Catherine Cheze} and Valentino Bettinardi and Dimitris Visvikis",
year = "2013",
month = "4",
day = "1",
doi = "10.2967/jnumed.112.110809",
language = "English",
volume = "54",
pages = "631--638",
journal = "Journal of Nuclear Medicine",
issn = "0161-5505",
publisher = "Society of Nuclear Medicine Inc.",
number = "4",

}

TY - JOUR

T1 - Generation of 4-dimensional CT images based on 4-dimensional PET-derived motion fields

AU - Fayad, Hadi J.

AU - Lamare, Frederic

AU - Le Rest, Catherine Cheze

AU - Bettinardi, Valentino

AU - Visvikis, Dimitris

PY - 2013/4/1

Y1 - 2013/4/1

N2 - Respiratory motion can potentially reduce accuracy in anatomic and functional image fusion from multimodality systems. It can blur the uptake of small lesions and lead to significant activity underestimation. Solutions presented to date include respiration- synchronized anatomic and functional acquisitions. To increase the signal-to-noise ratio of the synchronized PET images, methods using nonrigid transformations during the reconstruction process have been proposed. In most of these methods, 4-dimensional (4D) CT images were used to derive the required deformation matrices. However, variations between acquired 4D PET and corresponding CT image series due to differences in respiratory conditions during PET and CT acquisitions have been reported. In addition, the radiation dose burden resulting from a 4D CT acquisition may not be justifiable for every patient. Methods: In this paper, we present a method for the generation of dynamic CT images from the combination of one reference CT image and deformation matrices obtained from the elastic registration of 4D PET images not corrected for attenuation. On the one hand, our approach eliminates the need for the acquisition of dynamic CT. On the other hand, it also ensures a good match between CT and PET images, allowing accurate attenuation correction to be performed for respirationsynchronized PET acquisitions. Results: The proposed method was first validated on Monte Carlo-simulated datasets, and then on patient datasets (n 5 4) by comparing generated 4D CT images with the corresponding acquired original CT images. Different levels of PET image statistical quality were considered in order to investigate the impact of image noise in the derivation of the 4D CT series. Conclusion: Our results suggest that clinically relevant PET acquisition times can be used for the implementation of such an approach, making this an even more attractive solution considering the absence of the extra dose given by a standard 4D CT acquisition. Finally, this approach may be applicable to other multimodality devices such as PET/MR. COPYRIGHT

AB - Respiratory motion can potentially reduce accuracy in anatomic and functional image fusion from multimodality systems. It can blur the uptake of small lesions and lead to significant activity underestimation. Solutions presented to date include respiration- synchronized anatomic and functional acquisitions. To increase the signal-to-noise ratio of the synchronized PET images, methods using nonrigid transformations during the reconstruction process have been proposed. In most of these methods, 4-dimensional (4D) CT images were used to derive the required deformation matrices. However, variations between acquired 4D PET and corresponding CT image series due to differences in respiratory conditions during PET and CT acquisitions have been reported. In addition, the radiation dose burden resulting from a 4D CT acquisition may not be justifiable for every patient. Methods: In this paper, we present a method for the generation of dynamic CT images from the combination of one reference CT image and deformation matrices obtained from the elastic registration of 4D PET images not corrected for attenuation. On the one hand, our approach eliminates the need for the acquisition of dynamic CT. On the other hand, it also ensures a good match between CT and PET images, allowing accurate attenuation correction to be performed for respirationsynchronized PET acquisitions. Results: The proposed method was first validated on Monte Carlo-simulated datasets, and then on patient datasets (n 5 4) by comparing generated 4D CT images with the corresponding acquired original CT images. Different levels of PET image statistical quality were considered in order to investigate the impact of image noise in the derivation of the 4D CT series. Conclusion: Our results suggest that clinically relevant PET acquisition times can be used for the implementation of such an approach, making this an even more attractive solution considering the absence of the extra dose given by a standard 4D CT acquisition. Finally, this approach may be applicable to other multimodality devices such as PET/MR. COPYRIGHT

KW - 4D PET/CT

KW - Attenuation

KW - Respiratory motion

UR - http://www.scopus.com/inward/record.url?scp=84875767568&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84875767568&partnerID=8YFLogxK

U2 - 10.2967/jnumed.112.110809

DO - 10.2967/jnumed.112.110809

M3 - Article

VL - 54

SP - 631

EP - 638

JO - Journal of Nuclear Medicine

JF - Journal of Nuclear Medicine

SN - 0161-5505

IS - 4

ER -