Half-dose versus full-dose macrocyclic gadolinium at 3-T magnetic resonance imaging in paediatric bone and soft-tissue disease

Research output: Contribution to journalArticle

Abstract

BACKGROUND: Given the recent concerns about gadolinium-based contrast agent safety, dose reduction strategies are being investigated.

OBJECTIVE: To compare half-dose and standard full-dose gadoterate meglumine at 3-tesla (T) MRI in paediatric bone and soft-tissue diseases.

MATERIALS AND METHODS: We prospectively enrolled 45 children (age range 2.7 months to 17.5 years, median age 8.7 years, 49 total anatomical segments) with bone and soft-tissue diseases (neoplastic, inflammatory/infectious, ischaemic and vascular) imaged at 3-T MRI. Two consecutive half-doses of gadoterate meglumine (0.05 mmol/kg body weight) were administered. Two sets of post-contrast T1-weighted images were obtained, one after the first half dose and the other after the second half dose. For qualitative analysis, three radiologists, masked to the gadolinium dose, compared the diagnostic quality of the images. For quantitative analysis, we compared signal-to-noise ratio and contrast-to-noise ratio at half and full doses.

RESULTS: Signal-to-noise ratio and contrast-to-noise ratio did not vary significantly between the two groups. Qualitative analysis yielded excellent image quality in both post-contrast image datasets (Cohen κ=0.8).

CONCLUSION: In paediatric bone and soft-tissue 3-T MRI, it is feasible to halve the standard dose of gadoterate meglumine without losing image quality.

Original languageEnglish
Pages (from-to)1724-1735
Number of pages12
JournalPediatric Radiology
Volume48
Issue number12
DOIs
Publication statusPublished - Nov 2018

Fingerprint

Gadolinium
Magnetic Resonance Imaging
Signal-To-Noise Ratio
Pediatrics
Bone and Bones
Noise
Contrast Media
Blood Vessels
Body Weight
Safety
gadoterate meglumine

Cite this

@article{7ecec7836be9461bbe0ea617ab2d89f6,
title = "Half-dose versus full-dose macrocyclic gadolinium at 3-T magnetic resonance imaging in paediatric bone and soft-tissue disease",
abstract = "BACKGROUND: Given the recent concerns about gadolinium-based contrast agent safety, dose reduction strategies are being investigated.OBJECTIVE: To compare half-dose and standard full-dose gadoterate meglumine at 3-tesla (T) MRI in paediatric bone and soft-tissue diseases.MATERIALS AND METHODS: We prospectively enrolled 45 children (age range 2.7 months to 17.5 years, median age 8.7 years, 49 total anatomical segments) with bone and soft-tissue diseases (neoplastic, inflammatory/infectious, ischaemic and vascular) imaged at 3-T MRI. Two consecutive half-doses of gadoterate meglumine (0.05 mmol/kg body weight) were administered. Two sets of post-contrast T1-weighted images were obtained, one after the first half dose and the other after the second half dose. For qualitative analysis, three radiologists, masked to the gadolinium dose, compared the diagnostic quality of the images. For quantitative analysis, we compared signal-to-noise ratio and contrast-to-noise ratio at half and full doses.RESULTS: Signal-to-noise ratio and contrast-to-noise ratio did not vary significantly between the two groups. Qualitative analysis yielded excellent image quality in both post-contrast image datasets (Cohen κ=0.8).CONCLUSION: In paediatric bone and soft-tissue 3-T MRI, it is feasible to halve the standard dose of gadoterate meglumine without losing image quality.",
author = "Colafati, {Giovanna Stefania} and Enrica Rossi and Chiara Carducci and Simone Piga and Voicu, {Ioan Paul} and Angela Mastronuzzi and Paolo Tom{\`a}",
year = "2018",
month = "11",
doi = "10.1007/s00247-018-4204-y",
language = "English",
volume = "48",
pages = "1724--1735",
journal = "Pediatric Radiology",
issn = "0301-0449",
publisher = "Springer Verlag",
number = "12",

}

TY - JOUR

T1 - Half-dose versus full-dose macrocyclic gadolinium at 3-T magnetic resonance imaging in paediatric bone and soft-tissue disease

AU - Colafati, Giovanna Stefania

AU - Rossi, Enrica

AU - Carducci, Chiara

AU - Piga, Simone

AU - Voicu, Ioan Paul

AU - Mastronuzzi, Angela

AU - Tomà, Paolo

PY - 2018/11

Y1 - 2018/11

N2 - BACKGROUND: Given the recent concerns about gadolinium-based contrast agent safety, dose reduction strategies are being investigated.OBJECTIVE: To compare half-dose and standard full-dose gadoterate meglumine at 3-tesla (T) MRI in paediatric bone and soft-tissue diseases.MATERIALS AND METHODS: We prospectively enrolled 45 children (age range 2.7 months to 17.5 years, median age 8.7 years, 49 total anatomical segments) with bone and soft-tissue diseases (neoplastic, inflammatory/infectious, ischaemic and vascular) imaged at 3-T MRI. Two consecutive half-doses of gadoterate meglumine (0.05 mmol/kg body weight) were administered. Two sets of post-contrast T1-weighted images were obtained, one after the first half dose and the other after the second half dose. For qualitative analysis, three radiologists, masked to the gadolinium dose, compared the diagnostic quality of the images. For quantitative analysis, we compared signal-to-noise ratio and contrast-to-noise ratio at half and full doses.RESULTS: Signal-to-noise ratio and contrast-to-noise ratio did not vary significantly between the two groups. Qualitative analysis yielded excellent image quality in both post-contrast image datasets (Cohen κ=0.8).CONCLUSION: In paediatric bone and soft-tissue 3-T MRI, it is feasible to halve the standard dose of gadoterate meglumine without losing image quality.

AB - BACKGROUND: Given the recent concerns about gadolinium-based contrast agent safety, dose reduction strategies are being investigated.OBJECTIVE: To compare half-dose and standard full-dose gadoterate meglumine at 3-tesla (T) MRI in paediatric bone and soft-tissue diseases.MATERIALS AND METHODS: We prospectively enrolled 45 children (age range 2.7 months to 17.5 years, median age 8.7 years, 49 total anatomical segments) with bone and soft-tissue diseases (neoplastic, inflammatory/infectious, ischaemic and vascular) imaged at 3-T MRI. Two consecutive half-doses of gadoterate meglumine (0.05 mmol/kg body weight) were administered. Two sets of post-contrast T1-weighted images were obtained, one after the first half dose and the other after the second half dose. For qualitative analysis, three radiologists, masked to the gadolinium dose, compared the diagnostic quality of the images. For quantitative analysis, we compared signal-to-noise ratio and contrast-to-noise ratio at half and full doses.RESULTS: Signal-to-noise ratio and contrast-to-noise ratio did not vary significantly between the two groups. Qualitative analysis yielded excellent image quality in both post-contrast image datasets (Cohen κ=0.8).CONCLUSION: In paediatric bone and soft-tissue 3-T MRI, it is feasible to halve the standard dose of gadoterate meglumine without losing image quality.

U2 - 10.1007/s00247-018-4204-y

DO - 10.1007/s00247-018-4204-y

M3 - Article

C2 - 30046901

VL - 48

SP - 1724

EP - 1735

JO - Pediatric Radiology

JF - Pediatric Radiology

SN - 0301-0449

IS - 12