Helical Tomotherapy of the breast: Can thermoplastic immobilization improve the reproducibility of the treatment setup and the accuracy of the delivered dose?

S. Agostinelli, S. Garelli, A. Bellini, F. Pupillo, M. Guenzi, D. Bosetti, G. Blandino, G. Taccini

Research output: Contribution to journalArticle

Abstract

Purpose: To evaluate the impact of thermoplastic mask immobilization in the setup reproducibility and delivered dose for Helical Tomotherapy (HT) of the breast/chest wall. Methods: 16 patients treated with Accuray Hi-Art HT for breast-cancer were considered. Patients were positioned supine with arms extended above the head using Civco Wing Board (WB) system. In 50% of patients an Orfit thermoplastic mask was added in order to improve immobilization. Before each treatment fraction a megavoltage CT (MVCT) scan was taken and registered to the planning CT by experienced medical staff. The impact of thermoplastic mask was investigated analysing MVCT shift-roll data and MVCT dose distribution using Planned Adaptive software. Results: In the analysed cases, the addition of thermoplastic mask had minor impact on the lateral, longitudinal and roll data distribution. Variance of vertical shifts was significantly reduced in the WB+Orfit group. Van Herk's margins were not affected by addition of thermoplastic immobilization.In both groups, target coverage (V95) and maximum dose (D1) were almost identical to planned values. D1 of organs at risk were not significantly different in the two groups. Conclusions: Analysis of shift-roll data shows no improvement in the group of patients immobilized with the addition of thermoplastic mask. Van Herk's margin is quite large (7-10mm) in both groups evidencing the need to perform daily setup correction. The adapted dose distribution complies well with the planned one, showing that if MVCT is used before each treatment fraction, a 3mm margin (setup component) for CTVs expansion could be adequate.

Original languageEnglish
Pages (from-to)49-53
Number of pages5
JournalPhysica Medica
Volume31
Issue number1
DOIs
Publication statusPublished - 2015

Fingerprint

Intensity-Modulated Radiotherapy
Masks
immobilization
breast
Immobilization
Breast
masks
dosage
margins
wings
shift
Organs at Risk
Therapeutics
chest
Medical Staff
arts
Thoracic Wall
Art
organs
planning

Keywords

  • Breast tomotherapy
  • Interfraction error
  • Thermoplastic mask

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging
  • Physics and Astronomy(all)
  • Medicine(all)

Cite this

Helical Tomotherapy of the breast : Can thermoplastic immobilization improve the reproducibility of the treatment setup and the accuracy of the delivered dose? / Agostinelli, S.; Garelli, S.; Bellini, A.; Pupillo, F.; Guenzi, M.; Bosetti, D.; Blandino, G.; Taccini, G.

In: Physica Medica, Vol. 31, No. 1, 2015, p. 49-53.

Research output: Contribution to journalArticle

@article{1f50bef0a96c425e966f8c80ea5f60c7,
title = "Helical Tomotherapy of the breast: Can thermoplastic immobilization improve the reproducibility of the treatment setup and the accuracy of the delivered dose?",
abstract = "Purpose: To evaluate the impact of thermoplastic mask immobilization in the setup reproducibility and delivered dose for Helical Tomotherapy (HT) of the breast/chest wall. Methods: 16 patients treated with Accuray Hi-Art HT for breast-cancer were considered. Patients were positioned supine with arms extended above the head using Civco Wing Board (WB) system. In 50{\%} of patients an Orfit thermoplastic mask was added in order to improve immobilization. Before each treatment fraction a megavoltage CT (MVCT) scan was taken and registered to the planning CT by experienced medical staff. The impact of thermoplastic mask was investigated analysing MVCT shift-roll data and MVCT dose distribution using Planned Adaptive software. Results: In the analysed cases, the addition of thermoplastic mask had minor impact on the lateral, longitudinal and roll data distribution. Variance of vertical shifts was significantly reduced in the WB+Orfit group. Van Herk's margins were not affected by addition of thermoplastic immobilization.In both groups, target coverage (V95) and maximum dose (D1) were almost identical to planned values. D1 of organs at risk were not significantly different in the two groups. Conclusions: Analysis of shift-roll data shows no improvement in the group of patients immobilized with the addition of thermoplastic mask. Van Herk's margin is quite large (7-10mm) in both groups evidencing the need to perform daily setup correction. The adapted dose distribution complies well with the planned one, showing that if MVCT is used before each treatment fraction, a 3mm margin (setup component) for CTVs expansion could be adequate.",
keywords = "Breast tomotherapy, Interfraction error, Thermoplastic mask",
author = "S. Agostinelli and S. Garelli and A. Bellini and F. Pupillo and M. Guenzi and D. Bosetti and G. Blandino and G. Taccini",
year = "2015",
doi = "10.1016/j.ejmp.2014.09.007",
language = "English",
volume = "31",
pages = "49--53",
journal = "Physica Medica",
issn = "1120-1797",
publisher = "Associazione Italiana di Fisica Medica",
number = "1",

}

TY - JOUR

T1 - Helical Tomotherapy of the breast

T2 - Can thermoplastic immobilization improve the reproducibility of the treatment setup and the accuracy of the delivered dose?

AU - Agostinelli, S.

AU - Garelli, S.

AU - Bellini, A.

AU - Pupillo, F.

AU - Guenzi, M.

AU - Bosetti, D.

AU - Blandino, G.

AU - Taccini, G.

PY - 2015

Y1 - 2015

N2 - Purpose: To evaluate the impact of thermoplastic mask immobilization in the setup reproducibility and delivered dose for Helical Tomotherapy (HT) of the breast/chest wall. Methods: 16 patients treated with Accuray Hi-Art HT for breast-cancer were considered. Patients were positioned supine with arms extended above the head using Civco Wing Board (WB) system. In 50% of patients an Orfit thermoplastic mask was added in order to improve immobilization. Before each treatment fraction a megavoltage CT (MVCT) scan was taken and registered to the planning CT by experienced medical staff. The impact of thermoplastic mask was investigated analysing MVCT shift-roll data and MVCT dose distribution using Planned Adaptive software. Results: In the analysed cases, the addition of thermoplastic mask had minor impact on the lateral, longitudinal and roll data distribution. Variance of vertical shifts was significantly reduced in the WB+Orfit group. Van Herk's margins were not affected by addition of thermoplastic immobilization.In both groups, target coverage (V95) and maximum dose (D1) were almost identical to planned values. D1 of organs at risk were not significantly different in the two groups. Conclusions: Analysis of shift-roll data shows no improvement in the group of patients immobilized with the addition of thermoplastic mask. Van Herk's margin is quite large (7-10mm) in both groups evidencing the need to perform daily setup correction. The adapted dose distribution complies well with the planned one, showing that if MVCT is used before each treatment fraction, a 3mm margin (setup component) for CTVs expansion could be adequate.

AB - Purpose: To evaluate the impact of thermoplastic mask immobilization in the setup reproducibility and delivered dose for Helical Tomotherapy (HT) of the breast/chest wall. Methods: 16 patients treated with Accuray Hi-Art HT for breast-cancer were considered. Patients were positioned supine with arms extended above the head using Civco Wing Board (WB) system. In 50% of patients an Orfit thermoplastic mask was added in order to improve immobilization. Before each treatment fraction a megavoltage CT (MVCT) scan was taken and registered to the planning CT by experienced medical staff. The impact of thermoplastic mask was investigated analysing MVCT shift-roll data and MVCT dose distribution using Planned Adaptive software. Results: In the analysed cases, the addition of thermoplastic mask had minor impact on the lateral, longitudinal and roll data distribution. Variance of vertical shifts was significantly reduced in the WB+Orfit group. Van Herk's margins were not affected by addition of thermoplastic immobilization.In both groups, target coverage (V95) and maximum dose (D1) were almost identical to planned values. D1 of organs at risk were not significantly different in the two groups. Conclusions: Analysis of shift-roll data shows no improvement in the group of patients immobilized with the addition of thermoplastic mask. Van Herk's margin is quite large (7-10mm) in both groups evidencing the need to perform daily setup correction. The adapted dose distribution complies well with the planned one, showing that if MVCT is used before each treatment fraction, a 3mm margin (setup component) for CTVs expansion could be adequate.

KW - Breast tomotherapy

KW - Interfraction error

KW - Thermoplastic mask

UR - http://www.scopus.com/inward/record.url?scp=84927696530&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84927696530&partnerID=8YFLogxK

U2 - 10.1016/j.ejmp.2014.09.007

DO - 10.1016/j.ejmp.2014.09.007

M3 - Article

C2 - 25281291

AN - SCOPUS:84927696530

VL - 31

SP - 49

EP - 53

JO - Physica Medica

JF - Physica Medica

SN - 1120-1797

IS - 1