Il fenomeno del ricircolo in corso di emodialisi (Hemodialysis Vascular Access Recirculation)

Translated title of the contribution: Hemodialysis access recirculation

S. Alloatti, A. Magnasco, M. Manes, G. Bonfant

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Vascular access recirculation (R) allows the evaluation of the adequacy of the extracorporeal blood circuit in dialysis patients. The test verifies the correct needle position in patients with arterovenous fistulae (AVF) and the effective function of central venous catheters. In clinically uncomplicated native fistulae, a normal R test could avoid more complex procedures like blood flow measure or angiography. The AVF recirculation has two components, vascular access recirculation (AR) and cardiopulmonary recirculation (CPR). While the first phenomenon is well known, the second remained undetected for many years resulting in wrong R calculations with false positives. Using the correct formula, the great majority of AVF resulted in zero recirculation. The presence of R reduces the dialysis efficiency to critical levels, mainly in unsuspected cases. Among the numerous available R tests, the urea test is the oldest and historically the most commonly used method, but unfortunately it is labor intensive, with low sensitivity and specificity and with delayed results. The "ultrasound dilution"method is considered the gold standard, easy to perform, with good repeatability, but it is expensive requiring a specific device. Finally, the glucose infusion test (GIT) is a new low-cost test with immediate results and a very low detection limit, with good repeatability and high specificity and sensitivity.

Original languageItalian
Pages (from-to)438-445
Number of pages8
JournalGiornale italiano di nefrologia : organo ufficiale della Società italiana di nefrologia
Volume21
Issue number5
Publication statusPublished - Sep 1 2004

Fingerprint

Fistula
Renal Dialysis
Blood Vessels
Dialysis
Sensitivity and Specificity
Central Venous Catheters
Needles
Urea
Limit of Detection
Angiography
Costs and Cost Analysis
Glucose
Equipment and Supplies

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Il fenomeno del ricircolo in corso di emodialisi (Hemodialysis Vascular Access Recirculation). / Alloatti, S.; Magnasco, A.; Manes, M.; Bonfant, G.

In: Giornale italiano di nefrologia : organo ufficiale della Società italiana di nefrologia, Vol. 21, No. 5, 01.09.2004, p. 438-445.

Research output: Contribution to journalArticle

@article{da8b32c073834808bc54c97bbac90459,
title = "Il fenomeno del ricircolo in corso di emodialisi (Hemodialysis Vascular Access Recirculation)",
abstract = "Vascular access recirculation (R) allows the evaluation of the adequacy of the extracorporeal blood circuit in dialysis patients. The test verifies the correct needle position in patients with arterovenous fistulae (AVF) and the effective function of central venous catheters. In clinically uncomplicated native fistulae, a normal R test could avoid more complex procedures like blood flow measure or angiography. The AVF recirculation has two components, vascular access recirculation (AR) and cardiopulmonary recirculation (CPR). While the first phenomenon is well known, the second remained undetected for many years resulting in wrong R calculations with false positives. Using the correct formula, the great majority of AVF resulted in zero recirculation. The presence of R reduces the dialysis efficiency to critical levels, mainly in unsuspected cases. Among the numerous available R tests, the urea test is the oldest and historically the most commonly used method, but unfortunately it is labor intensive, with low sensitivity and specificity and with delayed results. The {"}ultrasound dilution{"}method is considered the gold standard, easy to perform, with good repeatability, but it is expensive requiring a specific device. Finally, the glucose infusion test (GIT) is a new low-cost test with immediate results and a very low detection limit, with good repeatability and high specificity and sensitivity.",
author = "S. Alloatti and A. Magnasco and M. Manes and G. Bonfant",
year = "2004",
month = "9",
day = "1",
language = "Italian",
volume = "21",
pages = "438--445",
journal = "Giornale italiano di nefrologia : organo ufficiale della Societ{\`a} italiana di nefrologia",
issn = "0393-5590",
number = "5",

}

TY - JOUR

T1 - Il fenomeno del ricircolo in corso di emodialisi (Hemodialysis Vascular Access Recirculation)

AU - Alloatti, S.

AU - Magnasco, A.

AU - Manes, M.

AU - Bonfant, G.

PY - 2004/9/1

Y1 - 2004/9/1

N2 - Vascular access recirculation (R) allows the evaluation of the adequacy of the extracorporeal blood circuit in dialysis patients. The test verifies the correct needle position in patients with arterovenous fistulae (AVF) and the effective function of central venous catheters. In clinically uncomplicated native fistulae, a normal R test could avoid more complex procedures like blood flow measure or angiography. The AVF recirculation has two components, vascular access recirculation (AR) and cardiopulmonary recirculation (CPR). While the first phenomenon is well known, the second remained undetected for many years resulting in wrong R calculations with false positives. Using the correct formula, the great majority of AVF resulted in zero recirculation. The presence of R reduces the dialysis efficiency to critical levels, mainly in unsuspected cases. Among the numerous available R tests, the urea test is the oldest and historically the most commonly used method, but unfortunately it is labor intensive, with low sensitivity and specificity and with delayed results. The "ultrasound dilution"method is considered the gold standard, easy to perform, with good repeatability, but it is expensive requiring a specific device. Finally, the glucose infusion test (GIT) is a new low-cost test with immediate results and a very low detection limit, with good repeatability and high specificity and sensitivity.

AB - Vascular access recirculation (R) allows the evaluation of the adequacy of the extracorporeal blood circuit in dialysis patients. The test verifies the correct needle position in patients with arterovenous fistulae (AVF) and the effective function of central venous catheters. In clinically uncomplicated native fistulae, a normal R test could avoid more complex procedures like blood flow measure or angiography. The AVF recirculation has two components, vascular access recirculation (AR) and cardiopulmonary recirculation (CPR). While the first phenomenon is well known, the second remained undetected for many years resulting in wrong R calculations with false positives. Using the correct formula, the great majority of AVF resulted in zero recirculation. The presence of R reduces the dialysis efficiency to critical levels, mainly in unsuspected cases. Among the numerous available R tests, the urea test is the oldest and historically the most commonly used method, but unfortunately it is labor intensive, with low sensitivity and specificity and with delayed results. The "ultrasound dilution"method is considered the gold standard, easy to perform, with good repeatability, but it is expensive requiring a specific device. Finally, the glucose infusion test (GIT) is a new low-cost test with immediate results and a very low detection limit, with good repeatability and high specificity and sensitivity.

UR - http://www.scopus.com/inward/record.url?scp=84892670986&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84892670986&partnerID=8YFLogxK

M3 - Articolo

VL - 21

SP - 438

EP - 445

JO - Giornale italiano di nefrologia : organo ufficiale della Società italiana di nefrologia

JF - Giornale italiano di nefrologia : organo ufficiale della Società italiana di nefrologia

SN - 0393-5590

IS - 5

ER -